Full-Text Articles in Biomedical Engineering and Bioengineering

Optimal Inertial Sensor Placement And Motion Detection For Epileptic Seizure Patient Monitoring, Babak Kamalizonouzi Dec 2012

Optimal Inertial Sensor Placement And Motion Detection For Epileptic Seizure Patient Monitoring, Babak Kamalizonouzi

Electronic Thesis and Dissertation Repository

Use of inertial sensory systems to monitor and detect seizure episodes in patients suffering from epilepsy is investigated via numerical simulations and experiments. Numerical simulations employ a mathematical model that is able to predict human body dynamic responses during a typical epileptic seizure. An optimized inertial sensor placement procedure is developed to address achievement of highest possible sensing resolution in determining angular accelerations with minimal errors. In addition, a joint torque estimation procedure is formulated to assist in the future development of a possible detection scheme. Experimental motion data obtained from an epileptic seizure patient as well as a healthy …


Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel Dec 2012

Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel

Mechanical Engineering

This report covers the design and construction of the recumbent racing tricycle for Mr. Robert T. Kelly, a disabled veteran. Unfortunately Rob’s right leg is five inches shorter than his left one and therefore is unable to properly operate standard cranks. Our team HandiTrike is composed of Sean Higginson, Kevin Howie, and Vinay Patel and our project requires us to come up with a design that is feasible to complete within the given three quarters, as well as allow Rob to gain full use of his tricycle. Currently Rob ‘s trike uses the standard crank set up found on most …


The Design And Testing Of A Solar Autoclave With Broad Spectrum Sterilization Capabilities, Sarah S. Trabia Nov 2012

The Design And Testing Of A Solar Autoclave With Broad Spectrum Sterilization Capabilities, Sarah S. Trabia

Honors College Theses

Energy is difficult to come by in developing countries and this interferes with the ability of doctors to provide good healthcare to their patients. Without decent sterilization, patients can become infected and diseases can spread throughout hospitals. This study involves designing a solar autoclave for developing countries that is as efficient as electrical autoclaves. The design is intended to not require any electrical input and to be affordable to those who cannot afford advanced medical equipment. Once the solar autoclave is designed, it will be tested to determine if it can sterilize equipment against a variety of different bacteria, including …


Development Of A Novel Handheld Device For Active Compensation Of Physiological Tremor, Abhijit Saxena Oct 2012

Development Of A Novel Handheld Device For Active Compensation Of Physiological Tremor, Abhijit Saxena

Electronic Thesis and Dissertation Repository

In microsurgery, the human hand imposes certain limitations in accurately positioning the tip of a device such as scalpel. Any errors in the motion of the hand make microsurgical procedures difficult and involuntary motions such as hand tremors can make some procedures significantly difficult to perform. This is particularly true in the case of vitreoretinal microsurgery. The most familiar source of involuntary motion is physiological tremor. Real-time compensation of tremor is, therefore, necessary to assist surgeons to precisely position and manipulate the tool-tip to accurately perform a microsurgery. In this thesis, a novel handheld device (AID) is described for compensation …


Preoperative Planning Of Robotics-Assisted Minimally Invasive Cardiac Surgery Under Uncertainty, Hamidreza Azimian Aug 2012

Preoperative Planning Of Robotics-Assisted Minimally Invasive Cardiac Surgery Under Uncertainty, Hamidreza Azimian

Electronic Thesis and Dissertation Repository

In this thesis, a computational framework for patient-specific preoperative planning of Robotics-Assisted Minimally Invasive Cardiac Surgery (RAMICS) is developed. It is expected that preoperative planning of RAMICS will improve the rate of success by considering robot kinematics, patient-specific thoracic anatomy, and procedure-specific intraoperative conditions. Given the significant anatomical features localized in the preoperative computed tomography images of a patient's thorax, port locations and robot orientations (with respect to the patient's body coordinate frame) are determined to optimize characteristics such as dexterity, reachability, tool approach angles and maneuverability. In this thesis, two approaches for preoperative planning of RAMICS are proposed that …


Vision-Based Robot Control In The Context Of Human-Machine Interactions, Andrzej Nycz Aug 2012

Vision-Based Robot Control In The Context Of Human-Machine Interactions, Andrzej Nycz

Doctoral Dissertations

This research has explored motion control based on visual servoing – in the context of complex human-machine interactions and operations in realistic environments. Two classes of intelligent robotic systems were studied in this context: operator assistance with a high dexterity telerobotic manipulator performing remote tooling-centric tasks, and a bio-robot for X-ray imaging of lower extremity human skeletal joints during natural walking. The combination of human-machine interactions and practical application scenarios has led to the following fundamental contributions: 1) exploration and evaluation of a new concept of acquiring fluoroscope images of musculoskeletal features of interest during natural human motion, 2) creation …


Evaluation Of Autonomous Robotic Milling Methodology For Natural Tooth-Shaped Implants Based On Sko Optimization, Yongki Yoon Jul 2012

Evaluation Of Autonomous Robotic Milling Methodology For Natural Tooth-Shaped Implants Based On Sko Optimization, Yongki Yoon

Mechanical & Aerospace Engineering Theses & Dissertations

Robotic surgery is one of the most demanding and challenging applications in the field of automatic control. One of the conventional surgeries, the dental implantation, is the standard methodology to place the artificial tooth root composed of titanium material into the upper or lower jawbone. During the dental implant surgery, mechanical removal of the bone material is the most critical procedure because it may affect the patient's safety including damage to the mandibular canal nerve and/or piercing the maxillary sinus. With this problem, even though short term survival rates are greater than 95%, long term success rate of the surgery …


Investigation Of In-Vivo Hindfoot And Orthotic Interactions Using Bi-Planar X-Ray Fluoroscopy, Kristen M. Bushey Jun 2012

Investigation Of In-Vivo Hindfoot And Orthotic Interactions Using Bi-Planar X-Ray Fluoroscopy, Kristen M. Bushey

Electronic Thesis and Dissertation Repository

A markerless RSA method was used to determine the effect of orthotics on the normal, pes planus and pes cavus populations. Computed tomography (CT) was used to create bone models that were imported into the virtual environment. Joint coordinate systems were developed to measure kinematic changes in the hindfoot during weight-bearing gait and quiet standing. The objectives of this thesis were to (1) implement a fluoroscopy-based markerless RSA system on the foot, (2) determine the effect of various orthotics at midstance of fully weight-bearing dynamic gait, and (3) determine the effect of orthotics as measured using three different techniques. Every …


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …


Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham Jun 2012

Hydraulically Driven Mechanical Representation Of A Biological System, Andrea Argouarch, Michael Mceachern, Brandon Parham

Biomedical Engineering

No abstract provided.


Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel Jun 2012

Viscoelastic Anisotropic Finite Element Mixture Model Of Articular Cartilage Using Viscoelastic Collagen Fibers And Validation With Stress Relaxation Data, Matthew Alexander Griebel

Master's Theses

Experimental results show that collagen fibers exhibit stress relaxation under tension and a highly anisotropic distribution. To further develop the earlier model of Stender [1], the collagen constituent was updated to reflect its intrinsic viscoelasticity and anisotropic distribution, and integrated with an existing mixture model with glycosaminoglycans and ground substance matrix. A two-term Prony series expansion of the quasi-linear viscoelastic model was chosen to model the viscoelastic properties of the collagen fibers. Material parameters were determined by using the simplex method to minimize the sum of squared errors between model results and experimental stress relaxation data of tissue in tension. …


A Refreshable And Portable E-Braille System For The Blind And Visually Impaired, Mohammad Yousef Saadeh May 2012

A Refreshable And Portable E-Braille System For The Blind And Visually Impaired, Mohammad Yousef Saadeh

UNLV Theses, Dissertations, Professional Papers, and Capstones

The objective of this research is to design an affordable Braille tactile display that is wearable, refreshable, and portable. The device is intended to be used as an output device that can playback stored media. It can be also incorporated with current Braille reading technologies. The device will control both the electrical and mechanical stimulations to optimize the sensation and ensure extended use of the device. This work is concerned mainly with the mechanical aspects of the design.

This research proposed the development of a finger-wearable, scanning-style electric stimulation based (electrotactile) Braille display with sensing and adaptive rendering/actuation functions for …


The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink May 2012

The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink

UNLV Theses, Dissertations, Professional Papers, and Capstones

Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …


Electrokinetic Transport Phenomena In Nanofluidic Devices, Mingkan Zhang Apr 2012

Electrokinetic Transport Phenomena In Nanofluidic Devices, Mingkan Zhang

Mechanical & Aerospace Engineering Theses & Dissertations

Nanofluidic devices have wide potential applications in biology, chemistry and medicine, and have been proven to be very valuable in sensing biological particles (e.g., DNA and proteins) due to their efficiency, sensitivity and portability. Electrokinetic control of ion, fluid, and particle transport by using only electric field is the most popular method employed in nanofluidic devices. A comprehensive understanding of the electrokinetic ion, fluid, and particle transport in nanofluidics is essential for developing nanofluidic devices for the detection of single molecules, such as the next generation nanopore-based DNA sequencing technology. This research explored numerical simulation of electrokinetic ion and fluid …


Contact Pressure Distribution Of Osteochondral Defects Of The Knee: Effects Of Non-Vertical Walls, Scott Ensminger Jan 2012

Contact Pressure Distribution Of Osteochondral Defects Of The Knee: Effects Of Non-Vertical Walls, Scott Ensminger

Wayne State University Theses

Purpose: To examine the relationship between well-shouldered osteochondral defects and

defects of different geometries by studying their effects on rim stress concentration and

load redistribution in the human knee.

Methods: Ten fresh-frozen cadaveric knees were mounted at 30° of flexion in a materials

testing machine. Digital electronic pressure sensors were placed in the medial and lateral

compartments of the knee. Dynamic pressure readings were recorded throughout the

loading and holding phases as each knee was loaded to 700N and held for 5 seconds.

Artificial defects were created in each knee to simulate well-shouldered defects and

beveled-defects. Loading was repeated for …


Feasibility Analysis Of Estrification Systems With Entrainers, Kang Wook Lee Jan 2012

Feasibility Analysis Of Estrification Systems With Entrainers, Kang Wook Lee

Dissertations and Theses

(Ethyl Acetate) and IPA (Isopropyl Acetate) production systems are studied in terms of the feasibility analysis. It is not feasible to retrieve pure products by a simple reactive distillation for IPA production system because CCR (Critical Composition Region) covers the entire desired binary edge for IPA system. On the other hand, even though CCR does not cover the entire desired binary edge of the EA system completely, internal reflux ratio (IRR) analysis does not allow the production of the pure product via reactive distillation for EA production system. To overcome the restraints, external entrainers are utilized to take advantage of …


Numerical Simulation And Experimentation Of Pulsatile Flows In Axisymmetric Arterial Models, Tadesse Gebreegziabher Jan 2012

Numerical Simulation And Experimentation Of Pulsatile Flows In Axisymmetric Arterial Models, Tadesse Gebreegziabher

Wayne State University Dissertations

ABSTRACT

NUMERICAL SIMULATION AND EXPERIMENTATION OF PULSATILE FLOWS IN AXISYMMETRIC ARTERIAL MODELS

by

TADESSE GEBREEGZIABHER

December 2011

Co-advisors: 1. Dr. Emmanuel Ayorinde 2. Dr. Trilochan Singh

Major: Mechanical Engineering

Degree: Doctor of Philosophy

The primary motivation for this dissertation is the fluid flow and structural response to unsteady blood flow in the human body. The research work is a synergistic merging of numerical simulation and experimentation. For the experiments, an all-encompassing, highly flexible experimental apparatus was designed and fabricated to facilitate a wide range of operating conditions, the range of which was chosen to accommodate mammalian cardiovascular system for both …


Explicit Finite Element Modeling Of The Human Lumbar Spine, Milind Rao Jan 2012

Explicit Finite Element Modeling Of The Human Lumbar Spine, Milind Rao

Electronic Theses and Dissertations

Validated finite element (FE) models of the functional spinal unit (FSU) and lumbar spine are essential in design-phase device development and in assessing the mechanics associated with normal spine function and degenerative disc disease (DDD), as well as the impact of fusion and total disc replacement (TDR). Although experimental data from fully intact specimens can be used for model calibration and validation, the contributions from the individual structures (disc, facets, and ligaments) may be inappropriately distributed. Hence, creation of decompression conditions or device implantations that require structure removal may not have the proper resulting mechanics. An explicit FE formulation may …