Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan
Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan
Electronic Thesis and Dissertation Repository
Reverse total shoulder arthroplasty (RTSA) is increasingly utilized in the aging population, with a growing list of surgical indications including rotator cuff tear arthropathy, proximal humerus fractures, and revision arthroplasty. Acromial insufficiency fractures following RTSA are poorly understood, difficult to diagnose, and associated with inferior clinical outcomes. There is limited knowledge in the literature regarding the etiology of post-operative acromial fractures. The purpose of this study is to evaluate the role of implant parameters on acromial strain following RTSA.
Using a cadaveric model, a custom designed modular RTSA system was implanted that allowed for evaluation of modifiable parameters including glenoid …
The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari
The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari
Electronic Thesis and Dissertation Repository
Abstract:
The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries
Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.
Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …
Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad
Design And Development Of A Novel Expanding Pedicle Screw For Use In The Osteoporotic Lumbar Spine, Parham Rasoulinejad
Electronic Thesis and Dissertation Repository
Pedicle screws are commonly utilized in spinal surgery; however, traditional designs often do not provide adequate fixation in osteoporotic spines. The objective of this thesis was to develop a novel expanding screw for use in osteoporotic lumbar pedicles. Helical screws capable of expanding post insertion were built on a rapid prototype machine. A materials testing machine performed axial load to failure tests in both Sawbones and cadaveric specimens comparing the new design to traditional screws (rate = 10mm/min to 20 mm). Output parameters included yield load, ultimate load, stiffness, energy to failure and total energy. The expanding screw showed a …