Development Of An Active Finger Motion Simulator: With In-Vitro Assessments Of Tendon Loads And Joint Kinematics, Mohammad Haddara Nov 2017

Development Of An Active Finger Motion Simulator: With In-Vitro Assessments Of Tendon Loads And Joint Kinematics, Mohammad Haddara

Electronic Thesis and Dissertation Repository

Musculoskeletal injuries of the finger far outnumber those of other joints, and while in-vitro motion simulators are useful for studying joint biomechanics and evaluating surgical repairs, considerably less simulator development has been reported for the finger compared to other joints. Replication of active musculoskeletal movement during in-vitro testing has been shown to be more representative of in-vivo motion patterns, and closed-loop motion controllers are the current state-of-the-art for in-vitro kinematics studies. However, an in-vitro motion simulator with closed-loop tendon load control and simultaneous tendon excursion control has not yet been reported for the finger. This thesis outlines the design and …


Influence Of Scapular Notching On Contact Mechanics And Simulator Wear Of Reverse Total Shoulder Arthroplasty Implants, Michael William Griffiths Oct 2017

Influence Of Scapular Notching On Contact Mechanics And Simulator Wear Of Reverse Total Shoulder Arthroplasty Implants, Michael William Griffiths

Electronic Thesis and Dissertation Repository

Scapular notching is a common complication of reverse total shoulder arthroplasty (RTSA) wherein the predominant focus of current literature has been on changes in osseous anatomy. However, the implications on RTSA performance from the damaged humeral cup is largely unknown. Therefore the present work describes the effects of the initiation and propagation of the humeral cup defect resulting from scapular notching through the use of finite element modeling and wear simulation, in order to assess changes in RTSA contact mechanics and tribological properties. A significant decrease in articular contact area and increase in maximum contact stress values was found for …


Experimental Measurements Of Far Field Cough Airflows Produced By Healthy And Influenza- Infected Human Subjects, Ahmed Faraj Alarbi Mohamed Sep 2017

Experimental Measurements Of Far Field Cough Airflows Produced By Healthy And Influenza- Infected Human Subjects, Ahmed Faraj Alarbi Mohamed

Electronic Thesis and Dissertation Repository

The present work details an experimental study of the cough airflow fields produced by subjects infected with influenza and when they are convalescent, together with data from healthy cohorts. The PIV and HWA measurements were taken far downstream at 1 m from the source within a cough chamber, along with droplet sampling at two different locations and nasal swabs from the sick subjects. The measured data over different seasons were used to evaluate and compare the results from sick, convalescent and healthy subjects. Although a total of 8 sick participants from winter 2014 and 2017 yielded positive nasal swab analysis, …


The Effect Of Radial And Ulnar Length Change On Distal Forearm Loading, Ahaoiza D. Isa Aug 2017

The Effect Of Radial And Ulnar Length Change On Distal Forearm Loading, Ahaoiza D. Isa

Electronic Thesis and Dissertation Repository

The effect of distal radial and ulnar length change on forearm bone loading is not well understood during simulated dynamic wrist loading. This thesis presents two studies which investigate the effect of these length changes on distal forearm loading under simulated dynamic wrist motion. The first study investigates the effect of radial length change on axial loading at the distal radius and ulna and relationship between ulnar variance and distal forearm loading. The complex variation in axial loads in the distal radius and during length change and dynamic wrist motion were studied and discussed. There was no correlation between native …


Assessment Of The Non-Linear Stress-Strain Characteristics Of Poly (Vinyl Alcohol) Cryogel, Mojdeh Zakeri Mar 2017

Assessment Of The Non-Linear Stress-Strain Characteristics Of Poly (Vinyl Alcohol) Cryogel, Mojdeh Zakeri

Electronic Thesis and Dissertation Repository

Creation of tissue-mimicking constructs is of great importance in the field of biomedical engineering. Poly (vinyl Alcohol) (PVA) is a biomaterial capable of simulating a wide range of geometries and mechanical properties of biological tissues. It is nontoxic, biocompatible, and easy to produce. PVA can be physically crosslinked by repeated cycles of freezing and thawing. The final product of this process is called PVA cryogel (PVA-C). The mechanical properties of PVA-C can be accurately controlled by changing PVA molecular weight, PVA concentration, and number and duration of freeze/thaw cycles (FTC). In this study, the stress-strain behavior of PVA cryogel was …