Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Wayne State University

Magnetic Resonance Imaging

Articles 1 - 4 of 4

Full-Text Articles in Biomedical Engineering and Bioengineering

Assessing Midbrain Abnormalities In Parkinson’S Disease Using Magnetic Resonance Imaging, Kiarash Ghassaban Jan 2021

Assessing Midbrain Abnormalities In Parkinson’S Disease Using Magnetic Resonance Imaging, Kiarash Ghassaban

Wayne State University Dissertations

Diagnosing early-stage Parkinson’s disease (PD) and its manifestations is still a clinical challenge. Previous imaging studies using iron, neuromelanin (NM) and the Nigrosome-1 (N1) measures in the substantia nigra (SN) by themselves have been unable to provide sufficiently high diagnostic performance for these methods to be adopted clinically. In this dissertation, we start by studying idiopathic PD patients at their intermediate stages of the disease to evaluate the role of global and regional iron in the major deep gray matter nuclei. Then, we only focus on the NM complex in the midbrain and how neuronal loss interact with iron overload …


Imaging Iron Content In Patients With Multiple Sclerosis Using Magnetic Resonance Imaging, Charbel Abdo Habib Jan 2013

Imaging Iron Content In Patients With Multiple Sclerosis Using Magnetic Resonance Imaging, Charbel Abdo Habib

Wayne State University Dissertations

The importance of iron in maintaining normal physiological processes in the human body has been well emphasized in the literature. However, "when iron behaves badly", its abnormal presence might lead to a spectrum of pathologies depending on what function has been altered. In the brain, for instance, abnormal iron content is thought to be associated with neurodegenerative diseases. In this dissertation, we study iron involvement in one of the most debilitating neurological diseases, multiple sclerosis (MS), using in vivo magnetic resonance imaging. We first test the sensitivity and specificity of the MR method used, known as susceptibility weighted imaging (SWI) …


Imaging The Vasculature With Susceptibility Weighted Imaging: Applications And Analysis, Samuel Barnes Jan 2010

Imaging The Vasculature With Susceptibility Weighted Imaging: Applications And Analysis, Samuel Barnes

Wayne State University Dissertations

Modern magnetic resonance imaging sequences allow detailed non-invasive imaging of both the arteries and veins. This work is divided into four sections that examine different applications and analysis of these sequences.

Susceptibility weighted imaging (SWI) typically generates excellent negative venous contrast. Techniques to generate positive arterial contrast in SWI images without degrading the venous contrast with a single echo are examined. By using high isotropic resolution and high readout bandwidth flow losses can be minimized (generating good arterial contrast) even at the long echo times required for good venous contrast. A downsampling filter is then used to restore lost venous …


Quantification Of Vascular Parametric Indices Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging, Areen Khaled Al.Bashir Jan 2010

Quantification Of Vascular Parametric Indices Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging, Areen Khaled Al.Bashir

Wayne State University Dissertations

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a non-invasive method used to evaluate the biological activity in early clinical trials of novel drugs targeting the tumor vasculature using gadolinium-DTPA (Gd) as a contrast agent. However, it has some limitations, such as reproducibility, data acquisition times, the presence of noise, extracting contrast concentration, estimating T1 relaxation and estimating pharmacokinetic parameters.

In this work, a new approach to used fixed T1(0) which provides more reproducible DCE results has been introduced. Using this new algorithm to quantify the vascular changes in DCE-MRI, a pre-clinical renal cell carcinoma (RCC) tumor model was used to …