Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen Mar 2020

Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen

Biomedical Engineering

This document comprises the steps taken by the senior project team to create a Proof-of-Concept Review for a Variable Pulsed Electric Field Ablation Catheter. First, the team did a significant amount of background research on related literature to better understand the current status of the project topic. After sufficient background information was obtained, project objectives and deliverables were finalized. Once customer requirements and the indications for use were completed, engineering specifications for the product and project were documented. All key customer requirements and engineering specs were related to the variable pulse functionality, maneuverability, as well as overall dimensioning of the …


Detection Method Of Subclinical Atherosclerosis Of The Carotid Artery With A Hemodynamics Modeling Approach, Marisa Peressini Jun 2018

Detection Method Of Subclinical Atherosclerosis Of The Carotid Artery With A Hemodynamics Modeling Approach, Marisa Peressini

Master's Theses

Subclinical atherosclerosis is an important area of research to evaluate stroke risk and predict localization of plaque. The current methods for detecting atherosclerosis risk are insufficient because it is based on The Framingham Risk Score and carotid intima media thickness, therefore an engineering detection model based on quantifiable data is needed. Laminar and turbulent flow, dictated by Reynolds number and relative roughness, was modeled through the carotid artery bifurcation to compare shear stress and shear rate. Computer-aided design and fluid flow software were used to model hemodynamics through the carotid artery. Data from the model was derived from governing equations …


Empirical Validation Of An In Silico Model Predicting The Fluid Dynamics Of An Iliac Artery Aneurysm, Rachel E. Willis Jun 2016

Empirical Validation Of An In Silico Model Predicting The Fluid Dynamics Of An Iliac Artery Aneurysm, Rachel E. Willis

Master's Theses

Iliac artery aneurysms are considered rare and difficult to detect and treat. Prompt diagnosis and timely intervention are essential, because the incidence of rupture is as high as 50%. The reported mortality rate for patients who undergo surgery for ruptured iliac artery aneurysm ranges from 50% to 70%. This study developed an in-vitro mechanical model of an iliac artery aneurysm to verify the accuracy of computer simulation software. Both the in vitro model and the in silico model can be used for further research to develop better treatment technology. This study also looks at the different types of iliac artery …


Fluid Flow Characterization In Rapid Prototyped Common Iliac Artery Aneurysm Molds, Daniel Cole Greinke Mar 2016

Fluid Flow Characterization In Rapid Prototyped Common Iliac Artery Aneurysm Molds, Daniel Cole Greinke

Master's Theses

The goal of this project was to determine whether i) fused deposition modeling could be employed to manufacture molds for vascular constructs, ii) whether vascular constructs could be created from these molds, and iii) to verify practical equivalence between observed fluid velocities. Dye tracking was to be employed to characterize fluid velocity profiles through the in vitro vascular constructs, including a half-vessel model and a full vessel model of an iliac artery aneurysm. A PDMS half-vessel construct was manufactured, and the movement of dye through the construct was tracked by a cellphone camera. Thresholds were applied to each video in …


Analysis Of Particles Thorough The Aortic Arch During Transcatheter Aortic Valve Replacement, Andrew Joseph Janicki Jun 2015

Analysis Of Particles Thorough The Aortic Arch During Transcatheter Aortic Valve Replacement, Andrew Joseph Janicki

Master's Theses

Ischemia caused by particles becoming dislodged during transcatheter aortic valve replacement (TAVR) is a possible complication of TAVR. The particles that become dislodged can travel out of the aortic valve, into the aortic arch, and then into either the brachiocephalic artery, the left common carotid artery, the left subclavian artery or continue into the descending aorta. If the particles continue into the descending aorta it poses no risk of causing ischemia however if it travels into the other arteries then it increases the possibility of the particle causing an ischemic event. The goal of this study is to determine what …


Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar Sep 2012

Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar

Master's Theses

A continuous flow, passive separation device was designed using an equivalent circuit to create variable flow rates for hydrodynamic focusing to drain channels and collection outlets. By varying the diameter of the sample inlet connection into the reservoir, the particle position was influenced significantly, which enabled desired separations. Additionally it was noted that the relative, horizontal position of the inlet also had a significant influence on particle position within the device. A dimensionless number, the Characteristic Sample Inlet, was developed to relate geometric properties of the inlet reservoir to downstream particle distribution. It was found that a 2:1 ratio between …


Evaluation Of Corrosion Properties For Use Of Az31b In Bioabsorbable Stents And In Vivo Corrosion Rate Prediction Using Fea, Jared Vidales, Austin Schader, Jenna Jerman, Michael Turovskiy Jun 2012

Evaluation Of Corrosion Properties For Use Of Az31b In Bioabsorbable Stents And In Vivo Corrosion Rate Prediction Using Fea, Jared Vidales, Austin Schader, Jenna Jerman, Michael Turovskiy

Materials Engineering

AZ31B was heat treated to evoke more controlled and uniform corrosion. 1/16” diameter AZ31B wire was cut into six samples each 1” long. The samples underwent heat treatments following ASTM B661-06. Samples were weighed and placed into three different in vitro environments. In the first scenario two samples of each heat treatment were individually placed in 50 ml of saline solution at 0.9% sodium, in a static test tube at 37°C temperature. Two samples were placed in 100 ml of 0.9% saline solution in a 250 ml stirring beaker with an average whirlpool depth of 1”. Two of each sample …