Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Biomedical Engineering and Bioengineering

Functional 3-D Cellulose And Nitrocellulose Paper-Based, Microfluidic Device Utilizing Elisa Technology For The Detection/Distinction Between Hemorrhagic And Ischemic Strokes, Alicia Leanne Holler Dec 2016

Functional 3-D Cellulose And Nitrocellulose Paper-Based, Microfluidic Device Utilizing Elisa Technology For The Detection/Distinction Between Hemorrhagic And Ischemic Strokes, Alicia Leanne Holler

Master's Theses

The purpose of this thesis project is to demonstrate and evaluate an enzyme-linked immunosorbent assay (ELISA) on a paper microfluidic device platform. The integration of ELISA technology onto paper microfluidic chips allows for a quantitative detection of stroke biomarkers, such as glial fibrillary acidic protein (GFAP). Dye experiments were performed to confirm fluid connectivity throughout the 3D chips. Several chip and housing designs were fabricated to determine an optimal design for the microfluidic device. Once this design was finalized, development time testing was performed. The results confirmed that the paper microfluidic device could successfully route fluid throughout its channels at …


Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer Aug 2016

Fluid Flow Characterization And In Silico Validation In A Rapid Prototyped Aortic Arch Model, Alexandra Mariel Knauer

Master's Theses

Transcatheter aortic heart valve replacement (TAVR) is a procedure to replace a failing aortic valve and is becoming the new standard of care for patients that are not candidates for open-heart surgery [2]. However, this minimally invasive technique has shown to cause ischemic brain lesions, or “silent infarcts”, in 90% of TAVR patients, which can increase the patient’s risk for stroke by two to four times in future years [3]. Claret Medical Inc., a medical device company, has developed a cerebral protection system that filters and captures embolic debris released during endovascular procedures, such as TAVR. This thesis utilized CT …


Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo Jun 2016

Prosthetic Leg Kit For Deployment In Developing Countries, Brian Murphy, Dominique Porcincula, Derek Morgan, Kendall Ruggles, Christian Aguayo

Biomedical Engineering

The World Health Organization estimates that over 30 million people require some sort of prosthetic technology. However, traditional prosthetic fitting practices take a lot of time and cost a lot of money, making them inaccessible to millions of people around the world. StandUP Worldwide is an interdisciplinary project team devoted to creating low-cost prosthetic technologies for use around the world, especially in resource poor areas. They are currently developing a low cost, below-the-knee prosthetic kit that can be easily deployed in a resource-poor area. The following presents their solution for a below-the-knee prosthetic socket, foot, and leg.


The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco Jun 2016

The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco

Master's Theses

Osteoarthritis (OA) is a degenerative disease of cartilage and bone tissue and the most common form of arthritis, accounting for US$ 10.5 billion in hospital charges in 2006. Obesity (OB) has been linked to increased risk of developing knee OA due to increased knee joint loads and varus-valgus misalignment. Walking is recommended as a weight-loss activity but it may increase risk of knee OA as OB gait increases knee loads. Cycling has been proposed as an alternative weight-loss measure, however, lack of studies comparing normal weight (NW) and OB subjects in cycling and gait hinder identification of exercises that may …


Fluid Flow Characterization In Rapid Prototyped Common Iliac Artery Aneurysm Molds, Daniel Cole Greinke Mar 2016

Fluid Flow Characterization In Rapid Prototyped Common Iliac Artery Aneurysm Molds, Daniel Cole Greinke

Master's Theses

The goal of this project was to determine whether i) fused deposition modeling could be employed to manufacture molds for vascular constructs, ii) whether vascular constructs could be created from these molds, and iii) to verify practical equivalence between observed fluid velocities. Dye tracking was to be employed to characterize fluid velocity profiles through the in vitro vascular constructs, including a half-vessel model and a full vessel model of an iliac artery aneurysm. A PDMS half-vessel construct was manufactured, and the movement of dye through the construct was tracked by a cellphone camera. Thresholds were applied to each video in …