Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Aneurysm (1)
- Arteriogenesis (1)
- BALB/C (1)
- Beamforming Optimization (1)
- Bifurcation (1)
-
- Biomarker (1)
- Biomarkers (1)
- Bionanotechnology (1)
- Bone Density (1)
- CdSe (1)
- Computer vision (1)
- Equine (1)
- Equivalent Thickness of Aluminum (ETA) (1)
- FEA (1)
- FIBER DIAMETER (1)
- Facial tracking (1)
- Fluorescent (1)
- GROUP DELAY (1)
- Gracilis (1)
- HISTOLOGY (1)
- Heart Sounds (1)
- Material Differences (1)
- Middle Cerebral Artery (1)
- Mouse replacements (1)
- Multiple Digital Stethoscope Apparatus (1)
- Myoelectric (1)
- NERVE CONDUCTION VELOCITY (1)
- NERVE FIBER SIZE (1)
- Nano (1)
- Nanocrystal (1)
Articles 1 - 7 of 7
Full-Text Articles in Biomedical Engineering and Bioengineering
The Effect Of Artery Bifurcation Angles On Fluid Flow And Wall Shear Stress In The Middle Cerebral Artery, Zachary Ramey Jones
The Effect Of Artery Bifurcation Angles On Fluid Flow And Wall Shear Stress In The Middle Cerebral Artery, Zachary Ramey Jones
Master's Theses
Saccular aneurysms are the abnormal plastic deformation of veins and arteries that can lead to lethal thrombus genesis or internal hemorrhaging. Medication and surgery greatly reduce the mortality rates, but treatment is limited by predicting who will develop aneurysms. A common location for saccular aneurysm genesis is at the main middle cerebral artery (MCA) bifurcation. The main MCA bifurcation is comprised of the M1 MCA segment, parent artery, and two M2 segments, daughter arteries. Studies have found that the lateral angle (LA) ratio of the MCA bifurcation is correlated with aneurysm formation. The LA ratio is defined as the angle …
Smooth Muscle Cell Organization In The Stem Region Of The Gracilis Collateral Circulation In Balb/C Mice, Laura Lenae Burckhardt
Smooth Muscle Cell Organization In The Stem Region Of The Gracilis Collateral Circulation In Balb/C Mice, Laura Lenae Burckhardt
Biomedical Engineering
Of the approximately 8 million Americans who suffer from ischemic peripheral arterial occlusive disease (PAOD), many present with intermittent claudication, or pain associated with exercise. Impaired vasodilation of resistance vessels is a potential explanation for this symptom. Occluded arteries can lead to increased flow through collateral vessels, which function as natural bypasses around the obstruction. This increase in blood flow and resulting shear stress can cause outward remodeling, or arteriogenesis, which improves the efficacy of collaterals. However, following femoral artery ligation in a mouse model of chronic ischemia, vasodilation in the stem region of collateral vessels is impaired at day …
Nerve Fiber Diameter Measurements Using Hematoxylin And Eosin Staining And Brightfield Microscopy To Assess The Novel Method Of Characterizing Peripheral Nerve Fiber Distributions By Group Delay, Jorge Arturo Vazquez
Nerve Fiber Diameter Measurements Using Hematoxylin And Eosin Staining And Brightfield Microscopy To Assess The Novel Method Of Characterizing Peripheral Nerve Fiber Distributions By Group Delay, Jorge Arturo Vazquez
Master's Theses
Peripheral neuropathies are a set of common diseases that affect the peripheral nervous system, causing damage to vital connections between various parts of the body and the brain and spinal cord. Different clinical conditions are known to selectively impact various size nerve fibers, which often makes it difficult to diagnose which peripheral neuropathy a patient might have. The nerve conduction velocity diagnostic test provides clinically useful information in the diagnosis of some peripheral neuropathies. This method is advantageous because it tends to be minimally invasive yet it provides valuable diagnostic information. However, this test does not determine characteristics of peripheral …
Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong
Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong
Master's Theses
For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …
Team Omnimouse, Derek J. Halman, Josh B. Porter, Steven A. Silver, Ian S. Stemper
Team Omnimouse, Derek J. Halman, Josh B. Porter, Steven A. Silver, Ian S. Stemper
Computer Engineering
INFORMATION, DATA, FIGURES AND DRAWINGS EMBODIED IN THIS DOCUMENT ARE STRICTLY CONFIDENTIAL AND ARE SUPPLIED ON THE UNDERSTANDING THAT THEY WILL NOT BE DISCLOSED TO THIRD PARTIES WITHOUT THE PRIOR WRITTEN CONSENT OF QUALITY OF LIFE PLUS.
Developent Of A Phospholipid Encapsulation Process For Quantum Dots To Be Used In Biologic Applications, Logan Grimes
Developent Of A Phospholipid Encapsulation Process For Quantum Dots To Be Used In Biologic Applications, Logan Grimes
Master's Theses
The American Cancer Society predicts that 1,665,540 people will be diagnosed with cancer, and 585,720 people will die from cancer in 2014. One of the most common types of cancer in the United States is skin cancer. Melanoma alone is predicted to account for 10,000 of the cancer related deaths in 2014. As a highly mobile and aggressive form of cancer, melanoma is difficult to fight once it has metastasized through the body. Early detection in such varieties of cancer is critical in improving survival rates in afflicted patients. Present methods of detection rely on visual examination of suspicious regions …
Material Differences In Equine Cortical And Trabecular Bone, Ryan B. Allen
Material Differences In Equine Cortical And Trabecular Bone, Ryan B. Allen
Master's Theses
A greater understanding of bone materials would be beneficial in creating more accurate computer models and in the making of biomedical products involving bone. This study set out to determine whether cortical and trabecular bone are two separate materials, or whether they are the same material with a variance in porosity. To answer this question, samples were taken from different sections of the equine metacarpus, underwent densitometry analysis and were statistically analyzed. The majority of results suggest that the material is the same between varying densities of bone and thus the same between cortical and trabecular bone. These particular results …