Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 25 of 25

Full-Text Articles in Biomedical Engineering and Bioengineering

Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda May 2022

Insole Fall Prevention Device, Nick M. Hughes, Andrew M. Slaboda

Biomedical Engineering

Falls among the aging population occur every single day, with 1 in every 5 resulting in some injury and 300,000 hospitalized every year with a hip fracture [1]. The most popular and effective way to mitigate these falls is through physical therapist intervention. However, with the increased popularity in telerehab, many patients at risk for falls cannot accurately convey their gait tendencies to their physical therapists from the comfort of their home or while not in direct contact with the PT. A device like an insole, implanted with force sensors, which measures different parts of a patient’s foot, could convey …


Integration Of Electrical Impedance Spectroscopy For Multichannel Cell Culture Measurement, Conard Chan Feb 2022

Integration Of Electrical Impedance Spectroscopy For Multichannel Cell Culture Measurement, Conard Chan

Master's Theses

ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY (EIS) has been widely used to study the electrical properties of biological material due to its non-invasive nature and experimental reliability. However, most of the precision impedance analyzers used in EIS only provide single- or two-channel measurements which are inadequate for larger-scale multiplexed measurements, such as those found in modern microfluidic cell culture experiments. The Biomedical Microsystems Laboratory has developed a 16-channel cell culture platform with integrated electrode arrays for monitoring cell growth and electrical properties (i.e., the so-called “electrical phenotype”). In this paper, a system consisting of a 16-channel solid-state analog multiplexer (MUX)paired with a low-cost, …


Classifying Electrocardiogram With Machine Learning Techniques, Hillal Jarrar Dec 2021

Classifying Electrocardiogram With Machine Learning Techniques, Hillal Jarrar

Master's Theses

Classifying the electrocardiogram is of clinical importance because classification can be used to diagnose patients with cardiac arrhythmias. Many industries utilize machine learning techniques that consist of feature extraction methods followed by Naive- Bayesian classification in order to detect faults within machinery. Machine learning techniques that analyze vibrational machine data in a mechanical application may be used to analyze electrical data in a physiological application. Three of the most common feature extraction methods used to prepare machine vibration data for Naive-Bayesian classification are the Fourier transform, the Hilbert transform, and the Wavelet Packet transform. Each machine learning technique consists of …


Portable Ventilator, Bradley C. Weeks, Jack W. Brewer, Sanders Sanabria Jun 2021

Portable Ventilator, Bradley C. Weeks, Jack W. Brewer, Sanders Sanabria

Electrical Engineering

The current COVID-19 pandemic has heavily impacted the healthcare system in the United States and elsewhere. The need for patients to have access to a hospital with a ventilator along with a shortage of ventilators for recovery and at-home care as a result of minimal hospital vacancy for patients has been greatly stressed. The presented problem is both an unmet demand and supply of portable and effective ventilators. Existing ventilators have many shortcomings that should be addressed: size, weight, cost, and complexity of current ventilators confines users to stay in a medical facility whilst being monitored by professionals. This both …


Smart Motor Syringe System, Conard Chan, Jenny Chiao Dec 2020

Smart Motor Syringe System, Conard Chan, Jenny Chiao

Electrical Engineering

Syringe pumps are widely used in many research applications especially in the applications that need precise control. Today most medical research utilizes syringes to control the fluid being pumped to the experiment objects. In most cases microscopic or nano-scopic motion control is required to acquire optimal results, such application includes purification of DNA/RNA from contaminants[1]. The high precision required to control the syringe pump makes it difficult to perform manually. This paper focuses on the design of an intelligent syringe pump motor control system to achieve reliable and precise control for biomedical experiments. This project improves medical research quality with …


Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen Mar 2020

Pulsed Electrical Field Ablation Modulation, Camille Lousie Dozois, Jason Tyler Arias, Courtnee Lin Madsen

Biomedical Engineering

This document comprises the steps taken by the senior project team to create a Proof-of-Concept Review for a Variable Pulsed Electric Field Ablation Catheter. First, the team did a significant amount of background research on related literature to better understand the current status of the project topic. After sufficient background information was obtained, project objectives and deliverables were finalized. Once customer requirements and the indications for use were completed, engineering specifications for the product and project were documented. All key customer requirements and engineering specs were related to the variable pulse functionality, maneuverability, as well as overall dimensioning of the …


Blood Glucose Predictor, Jessica Patterson Dec 2019

Blood Glucose Predictor, Jessica Patterson

Electrical Engineering

For my senior project, I perform data analysis using statistical methods to determine body metrics that correlate with blood glucose levels. Working with Dr. Tina Smilkstein, I take repeat measurements from 6 different volunteers to establish trends in bodily metric data. The data taken includes weight, body fat, pulse rate, VO2, blood glucose, blood pressure, hours slept, and quality of sleep. Using these values, I use the program MiniTab to view results.

A few examples of correlations with blood glucose found in this project are:

  • Systolic blood pressure for females had a regression line of 124.0 -0.3366*Blood Pressure. This indicates …


Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler Mar 2019

Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler

Master's Theses

Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …


Microfluidic Electrical Impedance Spectroscopy, John J. Foley Sep 2018

Microfluidic Electrical Impedance Spectroscopy, John J. Foley

Master's Theses

The goal of this study is to design and manufacture a microfluidic device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured ethanol impedance initially to show that values remain consistent over time. Impedance values of water and 1% wt. saltwater were compared to show that the device is able to detect changes in impedance, with up to a 60% reduction in electrical impedance in saltwater. Cells were …


Extended-Use Ecg Monitor, Daniel Aaron Soski Jun 2018

Extended-Use Ecg Monitor, Daniel Aaron Soski

Master's Theses

In this thesis, a prototype ECG monitor was developed that is integrated into an elastic shirt and takes a 3-lead ECG for over 5 days. The high-quality measurements can be used to identify markers indicative of various detrimental heart conditions. Measurements recorded by the device are encrypted and stored onto a micro-SD card. Current Holter monitors are expensive and have functional lives less than 48 hours; however, extended duration monitoring has been proven more useful in diagnosis. The device designed demonstrates that ECG measurements can be taken over longer durations without sacrificing quality, comfort, or device cost.


Computer-Aided Diagnoses (Cad) System: An Artificial Neural Network Approach To Mri Analysis And Diagnosis Of Alzheimer's Disease (Ad), Berizohar Padilla Cerezo Dec 2017

Computer-Aided Diagnoses (Cad) System: An Artificial Neural Network Approach To Mri Analysis And Diagnosis Of Alzheimer's Disease (Ad), Berizohar Padilla Cerezo

Master's Theses

Alzheimer’s disease (AD) is a chronic and progressive, irreversible syndrome that deteriorates the cognitive functions. Official death certificates of 2013 reported 84,767 deaths from Alzheimer’s disease, making it the 6th leading cause of death in the United States. The rate of AD is estimated to double by 2050. The neurodegeneration of AD occurs decades before symptoms of dementia are evident. Therefore, having an efficient methodology for the early and proper diagnosis can lead to more effective treatments.

Neuroimaging techniques such as magnetic resonance imaging (MRI) can detect changes in the brain of living subjects. Moreover, medical imaging techniques are the …


Skin Tone Tracking Device (Chromaband), Ziyang Bian Jun 2017

Skin Tone Tracking Device (Chromaband), Ziyang Bian

Computer Engineering

It’s long been said that your skin is a window into your health and with many illnesses the first signs of trouble actually show up in your skin. So if we have this natural warning system, then why isn’t anyone able to effectively use it to predict changes in our health? The problem is that currently there is no reliable way to accurately measure the change in skin tone and how these changes may or may not change with variations in health. This project’s aim is to design and develop a device that will record the changes in a user’s …


Poly Drop, Zachary T. Scott, Lilly J. Paul Jun 2017

Poly Drop, Zachary T. Scott, Lilly J. Paul

Computer Engineering

Poly Drop is a software interface to control an Open Drop digital micro-fluidics system. We obtained a hardware system from Gaudi labs. Our task was to create a Graphical User Interface that made the control of the device easier and more automated for better testing. We created software that had 3 parts: a control GUI, arduino code to control the hardware, and Image Analysis that gives the user information such as location and color of liquid drops as they move across the electrode grid of the Open Drop system. The GUI was developed using Java Swing. The communication between the …


Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani Oct 2015

Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani

Master's Theses

Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.

Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …


Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon Jun 2015

Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon

Master's Theses

This thesis designed and fabricated various devices that were interfaced to an IC for an active contact lens that notifies the user of an event by detection of an external wireless signal. The contact lens consisted of an embedded antenna providing communication with a 2.4GHz system, as well as inductive charging at an operating frequency of 13.56 MHz. The lens utilized a CBC005 5µAh thin film battery by Cymbet and a manufactured graphene super capacitor as a power source. The custom integrated circuit (IC) was designed using the On Semiconductor CMOS C5 0.6 µm process to manage …


Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll Jun 2015

Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll

Master's Theses

Insight Photonic Solutions Inc. has continued to develop their patented VT-DBR laser design; these wavelength tunable lasers promise marked image-quality and acquisition time improvements in SS-OCT applications.

To be well suited for SS-OCT, tunable lasers must be capable of producing a highly linear wavelength sweep across a tuning range well-matched to the medium being imaged; many different tunable lasers used in SS-OCT are compared to identify the optimal solution.

This work electrically and spectrally characterizes two completely new all-semiconductor VT-DBR designs to compare, as well. The Neptune VT-DBR, an O-band laser, operates around the 1310 nm range and is a …


Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong Aug 2014

Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong

Master's Theses

For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …


Alternate Computer Input Device For Individuals With Quadriplegia, Tobais Elder, Michelle Martinez, David Sylvester Jun 2014

Alternate Computer Input Device For Individuals With Quadriplegia, Tobais Elder, Michelle Martinez, David Sylvester

Biomedical Engineering

This project details the design development of an alternative computer input system that allows a person with quadriplegia to move a computer's cursor and activate left and right click button inputs. After researching and analyzing possible solutions, an end design was chosen that most appropriately satisfied all user requirements and engineering specifications. This final design employs a head mounted Inertial Measurement Unit (IMU) with 9 DoF (Degrees of Freedom) to track head movements and correlate these motions to computer cursor movements. A Sip-Puff Transducer monitors and interprets a user's application of negative and positive air pressure differentials to a vinyl …


Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst Jun 2014

Sonar For The Visually Impaired, Anastasia Newark, Edwin Ng, Scott Terhorst

Biomedical Engineering

There are currently no inexpensive assistive devices that allow the visually impaired detect low hanging objects that are above waist height and may cause injury, such as a rope or tree branch. The challenge presented to the team by the Quality of Life Plus Lab (QL+) was to develop a Sonar Cane device that attaches to a traditional white cane to address this problem. This device must be lightweight, inexpensive to manufacture, have a long battery life, and accurately detect obstacles to prevent user injury.


Computational Modeling To Evaluate Helical Electrode Designs For Use In Vagus Nerve Stimulation, Anthony W. Cowley Jun 2013

Computational Modeling To Evaluate Helical Electrode Designs For Use In Vagus Nerve Stimulation, Anthony W. Cowley

Master's Theses

An estimated 0.5% of world’s population has been diagnosed with epilepsy. Of these patients 20-30% will be unable to achieve seizure control with anti-epileptic drugs. Vagus nerve stimulation (VNS) may be an appropriate treatment option for some patients with pharmaceutically refractory, partial-onset seizures.

VNS therapy uses a helical electrode to interface between the implantable pulse generator and the vagus nerve. While there have been several studies related to the mechanical and electrical safety of such electrodes, little work has been done toward understanding the effectiveness of the helical electrode in nerve stimulation. A better understanding of the voltage field and …


Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser Jun 2012

Polygrasp: Reach; Myoelectric Prosthetic Hand Iteration, Devon Patrick Augustus, Mighells Blaed Deuel, Ian Noel Fraser, Nicholas Philip Moesser

Mechanical Engineering

Amputations are a common occurrence in soldiers returning home who have suffered the effects of IED and munitions explosions. For upper limb amputees, trans-radial amputations are the most common. Traditional hook devices do not offer an adequate level of normalcy for users, prompting the use of myoelectric devices. While current myoelectric devices do offer a more natural experience, they come with a host of other problems that makes their adoption by service personnel not desirable or not permitted by the VA. PolyGrasp Reach seeks to reduce weight and cost and improve performance. This addresses several of the issues with devices …


Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus Jun 2011

Heart-Rate Monitoring Control System Using Photoplethysmography (Ppg), Wesley Nguyen, Ryan Horjus

Electrical Engineering

No abstract provided.


Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do Mar 2011

Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do

Master's Theses

During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process. In addition, some applications of UEP are incorporated into the official releases of the device product. UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD). This thesis covers the flexible and reusable …


Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel Feb 2011

Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel

Master's Theses

As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.

Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …


Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman Jun 2009

Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman

Master's Theses

The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the …