Development And Exploration Of A Z-Shaped Foot And Ankle Internal Fixation Plate, Rhaz Shaghaghi Paul, Ian Hames, Sean Rich Jan 2019

Development And Exploration Of A Z-Shaped Foot And Ankle Internal Fixation Plate, Rhaz Shaghaghi Paul, Ian Hames, Sean Rich

Williams Honors College, Honors Research Projects

This paper will detail the design process of developing a Z-shaped foot and ankle internal fixation plating system. Group 6: Plates for the Sole was made up of 5 team members, who worked together to accommodate their client’s request to complete a biomechanical analysis of a Z-Plate design and a construct a prototype. The Z-Plate’s purpose is to provide podiatrists with a new solution that can fit nicely on the small, irregular bones of the foot, while also remaining strong enough to withstand the forces and torques of the foot.


Detecting, Segmenting And Tracking Bio-Medical Objects, Mingzhong Li Jan 2016

Detecting, Segmenting And Tracking Bio-Medical Objects, Mingzhong Li

Doctoral Dissertations

"Studying the behavior patterns of biomedical objects helps scientists understand the underlying mechanisms. With computer vision techniques, automated monitoring can be implemented for efficient and effective analysis in biomedical studies. Promising applications have been carried out in various research topics, including insect group monitoring, malignant cell detection and segmentation, human organ segmentation and nano-particle tracking.

In general, applications of computer vision techniques in monitoring biomedical objects include the following stages: detection, segmentation and tracking. Challenges in each stage will potentially lead to unsatisfactory results of automated monitoring. These challenges include different foreground-background contrast, fast motion blur, clutter, object overlap and …


Fiber Optic Bandage, Logan Mcneil May 2015

Fiber Optic Bandage, Logan Mcneil

Chancellor’s Honors Program Projects

No abstract provided.


Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili Dec 2010

Development Of Software To Estimate Pressures On The Residual Limbs Of Amputees By Means Of A Pylon Mounted Transducer, Malli K. Yalamanchili

UNLV Theses, Dissertations, Professional Papers, and Capstones

The alignment of prosthesis has been recognized as one of the main factors that determine successful prosthetic outcomes for trans-tibial amputees. Alignment is defined as the relative position and orientation of the prosthetic components. Misalignment can result in changes in the position and orientation of the joints of the leg and moments experienced by them during gait, increases in energy use, and discomfort or even tissue breakdown at the socket/stump interface. Hence it is very important to align the prosthesis in correct manner. Gait analysis can be used to examine the effects of incorrect alignment of the prosthesis during gait. …