Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 19 of 19

Full-Text Articles in Biomedical Engineering and Bioengineering

Rattus Norvegicus As A Biological Detector Of Clandestine Remains And The Use Of Ultrasonic Vocalizations As A Locating Mechanism, Gabrielle M. Johnston May 2023

Rattus Norvegicus As A Biological Detector Of Clandestine Remains And The Use Of Ultrasonic Vocalizations As A Locating Mechanism, Gabrielle M. Johnston

Master's Theses

In investigations, locating missing persons and clandestine remains are imperative. One way that first responder and police agencies can search for the remains is by using cadaver dogs as biological detectors. Cadaver dogs are typically used due to their olfactory sensitivity and ability to detect low concentrations of volatile organic compounds produced by biological remains. Cadaver dogs are typically chosen for their stamina, agility, and olfactory sensitivity. However, what is not taken into account often is the size of the animal and the expense of maintaining and training the animal. Cadaver dogs are typically large breeds that cannot fit in …


Trace Dna Detection Using Diamond Dye: A Recovery Technique To Yield More Dna, Leah Davis May 2023

Trace Dna Detection Using Diamond Dye: A Recovery Technique To Yield More Dna, Leah Davis

Master's Theses

This study aspires to find a new screening approach to trace DNA recovery techniques to yield a higher quantity of trace DNA from larger items of evidence. It takes the path of visualizing trace DNA on items of evidence with potential DNA so analysts can swab a more localized area rather than attempting to recover trace DNA through the general swabbing technique currently used for trace DNA recovery. The first and second parts consisted of observing trace DNA interaction with Diamond Dye on porous and non-porous surfaces.

The third part involved applying the Diamond Dye solution by spraying it onto …


Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones Nov 2022

Hypoxic Incubation Chamber, Simone Lisette Helfrich, Makenzie Nicole Jones

Master's Theses

This paper describes the design, manufacturing, and testing of a novel controllable hypoxic incubator with fully functional oxygen gas control and temperature control in a humid environment. On the current market, a majority of the few hypoxic incubators use pre-mixed gas that does not offer precise control over gas concentration. The objective for this project was to create a chamber that allows the user to set the O2 concentration to varying set points of % O2 while maintaining the chamber at a constant body temperature, CO2 level, humidity, and sterility. To start the project, multiple concepts were developed for the …


Integration Of Electrical Impedance Spectroscopy For Multichannel Cell Culture Measurement, Conard Chan Feb 2022

Integration Of Electrical Impedance Spectroscopy For Multichannel Cell Culture Measurement, Conard Chan

Master's Theses

ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY (EIS) has been widely used to study the electrical properties of biological material due to its non-invasive nature and experimental reliability. However, most of the precision impedance analyzers used in EIS only provide single- or two-channel measurements which are inadequate for larger-scale multiplexed measurements, such as those found in modern microfluidic cell culture experiments. The Biomedical Microsystems Laboratory has developed a 16-channel cell culture platform with integrated electrode arrays for monitoring cell growth and electrical properties (i.e., the so-called “electrical phenotype”). In this paper, a system consisting of a 16-channel solid-state analog multiplexer (MUX)paired with a low-cost, …


Classifying Electrocardiogram With Machine Learning Techniques, Hillal Jarrar Dec 2021

Classifying Electrocardiogram With Machine Learning Techniques, Hillal Jarrar

Master's Theses

Classifying the electrocardiogram is of clinical importance because classification can be used to diagnose patients with cardiac arrhythmias. Many industries utilize machine learning techniques that consist of feature extraction methods followed by Naive- Bayesian classification in order to detect faults within machinery. Machine learning techniques that analyze vibrational machine data in a mechanical application may be used to analyze electrical data in a physiological application. Three of the most common feature extraction methods used to prepare machine vibration data for Naive-Bayesian classification are the Fourier transform, the Hilbert transform, and the Wavelet Packet transform. Each machine learning technique consists of …


Electrochemical Detection Of Reactive Oxygen Species Via A Platinum Microelectrode Array, Victor M. Carriere Jr. Jan 2020

Electrochemical Detection Of Reactive Oxygen Species Via A Platinum Microelectrode Array, Victor M. Carriere Jr.

Master's Theses

Oxidative stress, an excess of endogenous or exogenous reactive oxygen species (ROS) in the body, is closely aligned with inflammatory responses. ROS such as hydrogen peroxide, superoxide, and radical hydroxyl ion serve essential functions in fighting infection, but chronic elevation of these species irreversibly damages cellular components. Given the central role of inflammation in a variety of diseases, including Alzheimer’s Disease, atherosclerosis, and rheumatoid arthritis, a low-cost, extracellular, non-invasive assay of ROS is needed.

This work reports the use of a platinum microelectrode array (Pt MEA)-based ceramic probe to detect time- and concentration-dependent variations in hydrogen peroxide (H2O2) production by …


Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler Mar 2019

Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler

Master's Theses

Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …


Microfluidic Electrical Impedance Spectroscopy, John J. Foley Sep 2018

Microfluidic Electrical Impedance Spectroscopy, John J. Foley

Master's Theses

The goal of this study is to design and manufacture a microfluidic device capable of measuring changes in impedance valuesof microfluidic cell cultures. Tocharacterize this, an interdigitated array of electrodes was patterned over glass, where it was then bonded to a series of fluidic networks created in PDMS via soft lithography. The device measured ethanol impedance initially to show that values remain consistent over time. Impedance values of water and 1% wt. saltwater were compared to show that the device is able to detect changes in impedance, with up to a 60% reduction in electrical impedance in saltwater. Cells were …


Extended-Use Ecg Monitor, Daniel Aaron Soski Jun 2018

Extended-Use Ecg Monitor, Daniel Aaron Soski

Master's Theses

In this thesis, a prototype ECG monitor was developed that is integrated into an elastic shirt and takes a 3-lead ECG for over 5 days. The high-quality measurements can be used to identify markers indicative of various detrimental heart conditions. Measurements recorded by the device are encrypted and stored onto a micro-SD card. Current Holter monitors are expensive and have functional lives less than 48 hours; however, extended duration monitoring has been proven more useful in diagnosis. The device designed demonstrates that ECG measurements can be taken over longer durations without sacrificing quality, comfort, or device cost.


Computer-Aided Diagnoses (Cad) System: An Artificial Neural Network Approach To Mri Analysis And Diagnosis Of Alzheimer's Disease (Ad), Berizohar Padilla Cerezo Dec 2017

Computer-Aided Diagnoses (Cad) System: An Artificial Neural Network Approach To Mri Analysis And Diagnosis Of Alzheimer's Disease (Ad), Berizohar Padilla Cerezo

Master's Theses

Alzheimer’s disease (AD) is a chronic and progressive, irreversible syndrome that deteriorates the cognitive functions. Official death certificates of 2013 reported 84,767 deaths from Alzheimer’s disease, making it the 6th leading cause of death in the United States. The rate of AD is estimated to double by 2050. The neurodegeneration of AD occurs decades before symptoms of dementia are evident. Therefore, having an efficient methodology for the early and proper diagnosis can lead to more effective treatments.

Neuroimaging techniques such as magnetic resonance imaging (MRI) can detect changes in the brain of living subjects. Moreover, medical imaging techniques are the …


Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani Oct 2015

Quantification Of Blood Flow Velocity Using Color Sensing, Aditya Deepak Sanghani

Master's Theses

Blood flow velocity is an important parameter that can give information on several pathologies including atherosclerosis, glaucoma, Raynaud’s phenomenon, and ischemic stroke [2,5,6,10]. Present techniques of measuring blood flow velocity involve expensive procedures such as Doppler echocardiography, Doppler ultrasound, and magnetic resonance imaging [11,12]. They cost from $8500-$20000. It is desired to find a low-cost yet equally effective solution for measuring blood flow velocity. This thesis has a goal of creating a proof of concept device for measuring blood flow velocity.

Finger blood flow velocity is investigated in this project. The close proximity to the skin of the finger’s arteries …


Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon Jun 2015

Design And Fabrication Techniques Of Devices For Embedded Power Active Contact Lens, Errol Heradio Leon

Master's Theses

This thesis designed and fabricated various devices that were interfaced to an IC for an active contact lens that notifies the user of an event by detection of an external wireless signal. The contact lens consisted of an embedded antenna providing communication with a 2.4GHz system, as well as inductive charging at an operating frequency of 13.56 MHz. The lens utilized a CBC005 5µAh thin film battery by Cymbet and a manufactured graphene super capacitor as a power source. The custom integrated circuit (IC) was designed using the On Semiconductor CMOS C5 0.6 µm process to manage …


Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll Jun 2015

Characterization Of Two Vernier-Tuned Distributed Bragg Reflector (Vt-Dbr) Lasers Used In Swept Source Optical Coherence Tomography (Ss-Oct), Greg M. Bergdoll

Master's Theses

Insight Photonic Solutions Inc. has continued to develop their patented VT-DBR laser design; these wavelength tunable lasers promise marked image-quality and acquisition time improvements in SS-OCT applications.

To be well suited for SS-OCT, tunable lasers must be capable of producing a highly linear wavelength sweep across a tuning range well-matched to the medium being imaged; many different tunable lasers used in SS-OCT are compared to identify the optimal solution.

This work electrically and spectrally characterizes two completely new all-semiconductor VT-DBR designs to compare, as well. The Neptune VT-DBR, an O-band laser, operates around the 1310 nm range and is a …


Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong Aug 2014

Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong

Master's Theses

For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …


Computational Modeling To Evaluate Helical Electrode Designs For Use In Vagus Nerve Stimulation, Anthony W. Cowley Jun 2013

Computational Modeling To Evaluate Helical Electrode Designs For Use In Vagus Nerve Stimulation, Anthony W. Cowley

Master's Theses

An estimated 0.5% of world’s population has been diagnosed with epilepsy. Of these patients 20-30% will be unable to achieve seizure control with anti-epileptic drugs. Vagus nerve stimulation (VNS) may be an appropriate treatment option for some patients with pharmaceutically refractory, partial-onset seizures.

VNS therapy uses a helical electrode to interface between the implantable pulse generator and the vagus nerve. While there have been several studies related to the mechanical and electrical safety of such electrodes, little work has been done toward understanding the effectiveness of the helical electrode in nerve stimulation. A better understanding of the voltage field and …


Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do Mar 2011

Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do

Master's Theses

During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process. In addition, some applications of UEP are incorporated into the official releases of the device product. UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD). This thesis covers the flexible and reusable …


Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel Feb 2011

Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel

Master's Theses

As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.

Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …


Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo Sep 2010

Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo

Master's Theses

The application of high frequency ultrasound is the key to higher resolution intravascular ultrasound (IVUS) images. The need to further improve the IVUS spatial resolution may drive the transducer center frequency even higher than the current 40 MHz range. However, increasing the center frequency may be challenging as it leads to stronger scattering echoes from blood. The high level of blood scattering echoes may obscure the arterial lumen and make image interpretation difficult. Blood backscatter levels increase with transmission center frequency at a much greater rate compared to arterial tissue. These different frequency dependencies provide a potential method to distinguish …


Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman Jun 2009

Time-Frequency Analysis Of Intracardiac Electrogram, Erik Brockman

Master's Theses

The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the …