Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 16 of 16

Full-Text Articles in Biomedical Engineering and Bioengineering

Restoring An Iso:5840-Compliant Pulse Duplicator Device For Hydrodynamic Performance Characterization Of Artificial Cardiac Valves, Denver Eagar Aug 2022

Restoring An Iso:5840-Compliant Pulse Duplicator Device For Hydrodynamic Performance Characterization Of Artificial Cardiac Valves, Denver Eagar

Biomedical Engineering Undergraduate Honors Theses

During the summer of 2021, I was employed as an intern at Dynatek Labs, an implantable prosthetics testing company located in southern Missouri. My primary project was to modernize an abandoned pulse duplicator device and protocol to allow the company to re-enter a market area which they left nearly 15 years prior: heart valve testing. The company halted this initiative due to changes in international testing standards in previous years. The International Standards Organization Cardiac Valves Working Group released the latest version of standards concerning artificial heart valve testing (ISO 5840) in January of 2021. Accordingly, my project required that …


3d Volumetric Mapping Of Tissue Properties Via A Catheter-Scale Microendoscope Imaging System, Andrew Stark May 2022

3d Volumetric Mapping Of Tissue Properties Via A Catheter-Scale Microendoscope Imaging System, Andrew Stark

Biomedical Engineering Undergraduate Honors Theses

The study of tumor microvasculature is an important area of interest for research and clinical communities; however, there are significant limitations in the clinical characterization of the tumor microenvironment. Optical methods offer quantitative real-time measurement of tissue structure and perfusion and can be miniaturized for deployment endoscopically into previously inaccessible locations. However, conventional optical methods (i.e., optical coherence tomography, white light endoscopy, etc.) gives limited information about tissue perfusion while the diameter of various optical probes along with the complexity of scanning mechanisms make it difficult to access certain areas. In this study, a new technique for characterizing the tumor …


Sequential Illumination In A Tomographic Microendoscopic Probe For Imaging Tumor Microvasculature, Zachariah Neumeier May 2022

Sequential Illumination In A Tomographic Microendoscopic Probe For Imaging Tumor Microvasculature, Zachariah Neumeier

Biomedical Engineering Undergraduate Honors Theses

Knowledge of colorectal cancer biology is improving how we approach cancer treatment. Specifically, the tumor microenvironment and abnormal angiogenesis are of particular interest. Optical methods are a prime candidate for research of the tumor microenvironment due to their ability to quantitively assess tissue structure and perfusion in real time. Particularly, the “transport scattering regime” has been identified as a method of obtaining high-resolution images and reflectance spectroscopy data; this light scattering regime has been demonstrated compatible with endoscopic imaging systems. In this study, a proof-of-concept optical imaging system is presented, capable of resolving absorbers within scattering turbid media using a …


Quantifying Mucosal Hemodynamics In A Murine Model Of Ulcerative Colitis With Diffuse Reflectance Spectroscopy, Elizabeth A. Bullard, Ariel I. Mundo, Shelby N. Bess, Kathryn P. Miller May 2021

Quantifying Mucosal Hemodynamics In A Murine Model Of Ulcerative Colitis With Diffuse Reflectance Spectroscopy, Elizabeth A. Bullard, Ariel I. Mundo, Shelby N. Bess, Kathryn P. Miller

Biomedical Engineering Undergraduate Honors Theses

Ulcerative colitis (UC) is a gastrointestinal, autoimmune disease that causes ulceration and inflammation of the colon with an incidence 10 out of every 100,000 people in North America and Western Europe. Though the exact etiology is uncertain, a number of studies have shown that inflammatory cells along with environmental factors, genetics, and lifestyle habits can contribute to the sustained inflammatory response. In order to determine the cellular mechanism behind relapse and remission of UC, researchers have frequently employed immunohistochemistry, western blotting and gene sequencing, but these destructive analysis methods require the removal of a sample, necessarily limiting these methods to …


New Force Transducer For Mitral Valve Chordae Tendinea, Joseph Berryman May 2021

New Force Transducer For Mitral Valve Chordae Tendinea, Joseph Berryman

Biomedical Engineering Undergraduate Honors Theses

In order to inform the future of mitral valve repair and replacement, more investigation into the mechanics of the sub-valvular structure is needed. Understanding the roles of each chord during valve closure requires a sensor capable of detecting these small forces with enough sensitivity to determine the characteristics of each of the chordal types. The focus of the cantilever force transducer is to maximize this sensitivity while also minimizing the invasiveness of the sensor on the overall function of the chord. The design utilizes flexible yet strong 3D printed resin and cantilever arms to improve the strain exerted on a …


Redesign And Quantitative Assessment Of An Accelerated Venous Valve Fatigue Apparatus, Megan Kueh May 2020

Redesign And Quantitative Assessment Of An Accelerated Venous Valve Fatigue Apparatus, Megan Kueh

Biomedical Engineering Undergraduate Honors Theses

Chronic venous insufficiency (CVI) is a form of cardiovascular disease that is caused when valves in the leg become incompetent. Current treatment methods serve to manage symptoms, but there are currently no ways to treat the underlying cause of CVI. A venous valve prosthetic made from a xenograft of a bovine jugular vein is one possible treatment method currently in the research phase. Prosthetic valves must be tested with an accelerated wear tester prior to approval for clinical testing. Although such testers exist for heart valves, physiological differences between heart and venous valves restrict the use those testers on venous …


Analysis Of Blood Purification Studies On Oxone Mediated Tempo-Oxidized Nano Cellulose Mixed-Matrix Membranes, Tony Roller May 2020

Analysis Of Blood Purification Studies On Oxone Mediated Tempo-Oxidized Nano Cellulose Mixed-Matrix Membranes, Tony Roller

Biomedical Engineering Undergraduate Honors Theses

End-stage renal disease (ESRD) is currently the ninth leading cause of death in the United States, and of the 661,00 Americans diagnosed with ESRD, approximately 468,800 were on hemodialysis in 2016. Hemodialysis refers to a technique where a machine combined with a membrane, often referred to as an artificial kidney, is used to clean blood by removing any waste such as urea, potassium, and other smaller waste products while preserving the concentrations and integrity of cells and proteins in the blood. It has been shown in artificial blood studies that cellulose nanomaterials, like TEMPO/Oxidized cellulose nanoparticles (TOCNs), can be integrated …


Characterization Of Oxone Mediated Tempo-Oxidized Nano Cellulose Mixed-Matrix Membranes During Ultrafiltration And Hemodialysis, Kristyn Robling May 2020

Characterization Of Oxone Mediated Tempo-Oxidized Nano Cellulose Mixed-Matrix Membranes During Ultrafiltration And Hemodialysis, Kristyn Robling

Biomedical Engineering Undergraduate Honors Theses

The ninth leading cause of death in the United States is kidney disease, and hemodialysis is the process most commonly prescribed for treatment. It utilizes a selectively permeable membrane filter to remove toxins such as urea from the blood and retain necessary protein levels. However, traditional filters, such as cellulose triacetate, used during dialysis can be inefficient in terms of separation performance and reduction of fouling. Recent exploration of nanoparticles has resulted in the creation of Oxone Mediated TEMPO-Oxidized Nano Cellulose which has properties that are believed to increase hydrophilicity, increase tensile capacity, decrease membrane resistance and lower fouling, making …


A Bioinstrumentation Active Learning Educational Module: The Design Of A Working Temperature Sensor Using A Ntc Thermistor, Baylor Bush May 2019

A Bioinstrumentation Active Learning Educational Module: The Design Of A Working Temperature Sensor Using A Ntc Thermistor, Baylor Bush

Biomedical Engineering Undergraduate Honors Theses

The Department of Biomedical Engineering at the University of Arkansas has continued to develop over the years, with more students enrolling in the program each year. Within the first biomedical engineering course, Introduction to Biomedical Engineering, various topics are introduced to students, and the topic of bioinstrumentation has been one of the most complex and difficult topics for students to comprehend through just a few lectures. In order to aid students in grasping these intricate concepts, an active learning module was developed in which students can work in groups to build a simple thermistor circuit as a temperature sensor. The …


Vector Flow Imaging In Pediatric Cardiology - Extracting And Validating Data, Mason Belue May 2019

Vector Flow Imaging In Pediatric Cardiology - Extracting And Validating Data, Mason Belue

Biomedical Engineering Undergraduate Honors Theses

In the field of bedside cardiac diagnostic imaging, Doppler Ultrasound (DU) is the gold standard for diagnosing heart conditions. The largest benefit of DU is its ability to noninvasively image cardiac flow and allow the estimation of blood velocity and quantification of anatomical disease. However, to get correct velocity estimation, the position of the transducer in relation to the flow field needs to be known. This is the problem of angle/direction dependency and limits DUs accuracy when imaging in areas where perfect alignment or exact position of the transducer in relation to flow field is not possible or known, such …


Extraction And Analysis Of Vector Flow Imaging Data In A Pediatric Population, Bailey Stinnett May 2018

Extraction And Analysis Of Vector Flow Imaging Data In A Pediatric Population, Bailey Stinnett

Biomedical Engineering Undergraduate Honors Theses

Vector flow imaging (VFI) is a new ultrasound technology that provides real time, angle-independent visualization of flow velocities in the heart and great vessels. Thus far, VFI has been used for superficial applications due to the limited penetration depth of available transducer probes; however, this depth in smaller pediatric patients enables adequate aortic views. In this project, VFI was used to study pediatric aortic stenosis (PAS)—a congenital heart defect that results in the narrowing of the aorta and/or aortic valve. The decision to refer PAS patients for surgical or catheter-based intervention is initially based on Doppler ultrasound. VFI is potentially …


Pressure Acquisition System For In Vitro Mitral Valve Analysis, Laura Peck May 2018

Pressure Acquisition System For In Vitro Mitral Valve Analysis, Laura Peck

Biomedical Engineering Undergraduate Honors Theses

In vitro testing of the mitral valve chordae tendineae is utilized to aid in the understanding of the stresses that occur in vivo and improve upon surgical solutions that exist for mitral valve repair. This project aimed to design the water control system for a left heart simulation chamber, as well as the pressure acquisition inside the chamber. A solenoid valve was utilized to control the water supply to the tank and was powered utilizing National Instruments software. National Instruments hardware and software was also used with the pressure transducer in order to obtain pressure readings from the chamber. The …


Detection Of Leukocytes Stained With Acridine Orange Using Unique Spectral Features Acquired From An Image-Based Spectrometer, Courtney J. Hunter May 2017

Detection Of Leukocytes Stained With Acridine Orange Using Unique Spectral Features Acquired From An Image-Based Spectrometer, Courtney J. Hunter

Biomedical Engineering Undergraduate Honors Theses

A leukocyte differential count can be used to diagnosis a myriad blood disorders, such as infections, allergies, and efficacy of disease treatments. In recent years, attention has been focused on developing point-of-care (POC) systems to provide this test in global health settings. Acridine orange (AO) is an amphipathic, vital dye that intercalates leukocyte nucleic acids and acidic vesicles. It has been utilized by POC systems to identify the three main leukocyte subtypes: granulocytes, monocytes, and lymphocytes. Subtypes of leukocytes can be characterized using a fluorescence microscope, where the AO has a 450 nm excitation wavelength and has two peak emission …


Intravital Microscopy Of Tumor Oxygenation And Glycolytic Demand, Jesse D. Ivers May 2016

Intravital Microscopy Of Tumor Oxygenation And Glycolytic Demand, Jesse D. Ivers

Biomedical Engineering Undergraduate Honors Theses

There is growing concern about the over treatment of cancer because treatments are based primarily on tumor anatomy. In this study, we aim to begin the process of addressing that issue by developing an intravital technique for optically analyzing tumor biology. Two traits were identified as having significant importance in the aggression of a tumor, vascular oxygenation (SO2) and glycolytic demand. Dorsal skin flap window chambers were implanted and 4T1 and 67NR cancer cells were injected to provide a tumor model for the development of this intravital quantification technique. This study provides a detailed protocol from instrumentation setup to surgical …


Design Of A 3d-Printed Device For Diffuse Reflectance Spectroscopy Calibration As A Step Towards Clinical Translation, Nontapoth Vongkittiargorn May 2016

Design Of A 3d-Printed Device For Diffuse Reflectance Spectroscopy Calibration As A Step Towards Clinical Translation, Nontapoth Vongkittiargorn

Biomedical Engineering Undergraduate Honors Theses

The diffusive reflectance and spectroscopic microendoscopy (DRSME) is a multimodal imaging system that harnesses its usefulness from different light sources. One of the modalities, diffuse reflectance spectroscopy (DRS), has been used in our lab to investigate optical properties of epithelial tissues using a broadband white light as the main source. Calibration of DRS is required as it can obtain the maximum intensity and convert it to absolute reflectance. Current manual-adjusted calibration can be lengthy and often lead to inconsistent results. Therefore, a new method of calibration is introduced where additive manufacturing (or 3D printing) technology is fully utilized.

The instrumentation …


Localized Immunotherapy Delivery Using Injectable In Situ Forming Chitosan Hydrogel, Seth Washispack May 2016

Localized Immunotherapy Delivery Using Injectable In Situ Forming Chitosan Hydrogel, Seth Washispack

Biomedical Engineering Undergraduate Honors Theses

Cytokine-based cancer immunotherapies stimulate a host’s immune system to fight cancer. In particular, interleukin-12 (IL-12), a potent pro-inflammatory cytokine, has demonstrated the ability to eliminate tumors in a number of preclinical models. Toxicities associated with the systemic delivery of IL-12 have precluded its use in the clinic. We are developing a novel chitosan-based hydrogel to maintain high local concentrations of cytokines, such as IL-12, in the tumor while minimizing its systemic dissemination. This hydrogel was found to form spontaneously within ten seconds of mixing two proprietary components. To increase the usefulness of the hydrogel, an efficient mixing and delivery system …