Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Bioimaging and Biomedical Optics

2013

Institution
Keyword
Publication

Articles 1 - 27 of 27

Full-Text Articles in Biomedical Engineering and Bioengineering

Reconstruction Of Patient-Specific Bone Models From X-Ray Radiography, Hatem Amin Abdel Fattah El Dakhakhni Dec 2013

Reconstruction Of Patient-Specific Bone Models From X-Ray Radiography, Hatem Amin Abdel Fattah El Dakhakhni

Doctoral Dissertations

The availability of a patient‐specific bone model has become an increasingly invaluable addition to orthopedic case evaluation and planning [1]. Utilized within a wide range of specialized visualization and analysis tools, such models provide unprecedented wealth of bone shape information previously unattainable using traditional radiographic imaging [2]. In this work, a novel bone reconstruction method from two or more x‐ray images is described. This method is superior to previous attempts in terms of accuracy and repeatability. The new technique accurately models the radiological scene in a way that eliminates the need for expensive multi‐planar radiographic imaging systems. It is also …


Web-Based Simulation And Training Environment For Laparoscopic Camera Calibration, Kartik Thakore Oct 2013

Web-Based Simulation And Training Environment For Laparoscopic Camera Calibration, Kartik Thakore

Electronic Thesis and Dissertation Repository

Endoscopic cameras are increasingly employed in image-guidance procedures, where the video images must be registered to data from other modalities. However, such cameras are susceptible to distortions, requiring calibration before images can be used for registration, tracking and 3D reconstruction. Camera calibration is learned in a laboratory setting, where configuring and adjusting the physical setup is tedious and not necessarily conducive to learning. A centralized resource that utilizes 3D interactive components needs to be available for training on camera calibration. In this project, a web-based training environment for camera calibration is implemented called SimCAM. SimCAM was developed using the Web …


Characterization Of Two-Dimensional Oculomotor Control During Goal-Directed Eye Movements In Humans, Vincent Dang Oct 2013

Characterization Of Two-Dimensional Oculomotor Control During Goal-Directed Eye Movements In Humans, Vincent Dang

Master's Theses (2009 -)

Oculomotor control is a subset of sensorimotor control that allows humans to make extremely accurate eye movements for ADL. Impairments to oculomotor control can increase the impact of sensorimotor control deficits, especially in neurodegenerative diseases such as MS. Here, a two-dimensional computational control system of saccades and smooth-pursuit eye movements was compiled from literature to systematically characterize oculomotor control in eight visually-healthy humans as a precursor to studying the relationship between oculomotor and sensorimotor control in patient populations. Subjects visually tracked a single dot on a 41 x 30.5 cm monitor in a dark room while eye positions were recorded …


Fabricating Cost-Effective Nanostructures For Biomedical Applications, Erden Ertorer Sep 2013

Fabricating Cost-Effective Nanostructures For Biomedical Applications, Erden Ertorer

Electronic Thesis and Dissertation Repository

In this thesis we described inexpensive alternatives to fabricate nanostructures on planar substrates and provided example applications to discuss the efficiency of fabricated nanostructures.

The first method we described is forming large area systematically changing multi-shape nanoscale structures on a chip by laser interference lithography. We analyzed the fabricated structures at different substrate positions with respect to exposure time, exposure angle and associated light intensity profile. We presented experimental details related to the fabrication of symmetric and biaxial periodic nanostructures on photoresist, silicon surfaces, and ion-milled glass substrates. Behavior of osteoblasts and osteoclasts on the nanostructures was investigated. These results …


Automated Segmentation Of Left And Right Ventricles In Mri And Classification Of The Myocarfium Abnormalities, Cyrus (Mohammad Saleh) Nambakhsh Sep 2013

Automated Segmentation Of Left And Right Ventricles In Mri And Classification Of The Myocarfium Abnormalities, Cyrus (Mohammad Saleh) Nambakhsh

Electronic Thesis and Dissertation Repository

A fundamental step in diagnosis of cardiovascular diseases, automated left and right ventricle (LV and RV) segmentation in cardiac magnetic resonance images (MRI) is still acknowledged to be a difficult problem. Although algorithms for LV segmentation do exist, they require either extensive training or intensive user inputs. RV segmentation in MRI has yet to be solved and is still acknowledged a completely unsolved problem because its shape is not symmetric and circular, its deformations are complex and varies extensively over the cardiac phases, and it includes papillary muscles. In this thesis, I investigate fast detection of the LV endo- and …


Vascular Segmentation Algorithms For Generating 3d Atherosclerotic Measurements, Eranga Ukwatta Aug 2013

Vascular Segmentation Algorithms For Generating 3d Atherosclerotic Measurements, Eranga Ukwatta

Electronic Thesis and Dissertation Repository

Atherosclerosis manifests as plaques within large arteries of the body and remains as a leading cause of mortality and morbidity in the world. Major cardiovascular events may occur in patients without known preexisting symptoms, thus it is important to monitor progression and regression of the plaque burden in the arteries for evaluating patient's response to therapy. In this dissertation, our main focus is quantification of plaque burden from the carotid and femoral arteries, which are major sites for plaque formation, and are straight forward to image noninvasively due to their superficial location. Recently, 3D measurements of plaque burden have shown …


Piv-Based Investigation Of Hemodynamic Factors In Diseased Carotid Artery Bifurcations With Varying Plaque Geometries, Sarah Kefayati Aug 2013

Piv-Based Investigation Of Hemodynamic Factors In Diseased Carotid Artery Bifurcations With Varying Plaque Geometries, Sarah Kefayati

Electronic Thesis and Dissertation Repository

Ischemic stroke is often a consequence of complications due to clot formation (i.e. thrombosis) at the site of an atherosclerotic plaque developed in the internal carotid artery. Hemodynamic factors, such as shear-stress forces and flow disturbances, can facilitate the key mechanisms of thrombosis. Atherosclerotic plaques can differ in the severity of stenosis (narrowing), in eccentricity (symmetry), as well as inclusion of ulceration (wall roughness). Therefore, in terms of clinical significance, it is important to investigate how the local hemodynamics of the carotid artery is mediated by the geometry of plaque. Knowledge of thrombosis-associated hemodynamics may provide a basis to introduce …


Numerical Investigation Of The Interdependence Between Humeral Implant Position And Bone Removal Amount For Total Elbow Arthroplasty, Alexander J. Heroux Aug 2013

Numerical Investigation Of The Interdependence Between Humeral Implant Position And Bone Removal Amount For Total Elbow Arthroplasty, Alexander J. Heroux

Electronic Thesis and Dissertation Repository

Total elbow arthroplasty is a surgical procedure used to replace an afflicted articulation with prosthetic joint components. A good alignment between the native and prosthetic flexion-extension axes of the elbow is required to preserve its functionality. However, this is often unobtainable because of the mismatch between humeral canal and implant stem geometries. To correct this, surgeons are often required to intraoperatively make error-prone decisions when determining an appropriate implant posture that minimizes the amount of cortical bone to be removed while maintaining the alignment between the two flexion-extension axes. To address this issue, the present study has developed computational tools …


Reproducibility Of Hyperpolarized Xenon-129 Magnetic Resonance Imaging, Nikhil Kanhere Jul 2013

Reproducibility Of Hyperpolarized Xenon-129 Magnetic Resonance Imaging, Nikhil Kanhere

Electronic Thesis and Dissertation Repository

Spirometry and plethysmography provide gold standard measurements of obstructive lung disease, although these are global measurements of lung function made at the mouth, of a highly regionally heterogeneous disease. Hyperpolarized 129Xe magnetic resonance imaging (MRI) is a non-invasive, non-radiation-based imaging tool for visualizing regional lung structure and function. However, the reproducibility of 129Xe MRI measurements has not yet been studied or determined. Hence, in this thesis, we evaluated the reproducibility of 129Xe MRI using quantitative measurements such as ventilation defect percent (VDP). We showed that 129Xe VDP had high intra-observer and inter-observer reproducibility for repeated scans …


Protein Loop Length Estimation From Medium Resolution Cryoem Images, Andrew R. Mcknight Jul 2013

Protein Loop Length Estimation From Medium Resolution Cryoem Images, Andrew R. Mcknight

Computer Science Theses & Dissertations

In the post-genomic era, proteomics research presents a new frontier in life science. Proteins play roles in virtually every biological process, and understanding their atomic structures is the key to unraveling how they carry out their work. Compared to the over half million protein sequences in UniProt, only around 25,000 unique sequences have been atomically modeled and deposited to PDB (Protein Databank). Cryoelectron Microscopy (cryoEM) is an important biophysical technique that produces 3D subnanometer resolution images of molecules not amenable to past approaches like x-ray crystallography or nuclear magnetic resonance. De novo modeling is becoming a promising approach to derive …


An Fmri Study On Supra-Spinal Contributions To Upper And Lower Limb Motor Control, Shancheng Bao Jul 2013

An Fmri Study On Supra-Spinal Contributions To Upper And Lower Limb Motor Control, Shancheng Bao

Master's Theses (2009 -)

The differences in the neural mechanisms contributing to upper and lower extremity movement have not been fully elucidated, and this might be a factor that leads to the ineffectiveness of rehabilitation techniques for most stroke survivors. It is unclear whether therapies designed for upper extremities should also be used for the lower extremities, and vice versa. In this study, fMRI was used to examine the supraspinal control of UE and LE movement in both neurologically intact individuals and people with post-stroke hemiparesis. We compared the location, volume, and intensity of brain activity associated with upper and lower extremity pedaling and …


Fluorescence Characterization Of Quantum Dots For Use As Biomarkers, Logan M. Grimes Jun 2013

Fluorescence Characterization Of Quantum Dots For Use As Biomarkers, Logan M. Grimes

Materials Engineering

Fluorescence profiles of quantum dots (QDs) were characterized to select the ideal QDs for encapsulation in phospholipids for use as biomarkers to selectively adhere to cancer cells. QDs were synthesized and extracted 0, 30, 60, and 90 seconds after precursor compounds were mixed. These extractions were isolated by extraction time. Portions from each vial were coated in a zinc sulfide shelling procedure, leaving at least half of the QD solution unshelled. These samples were characterized over four days to monitor fluctuations in fluorescence. This was done utilizing an Ocean Optics spectrometer in conjunction with Spectra Suite software. The central wavelength, …


Microcapsule Containing Lactic Acid Bacteria For Treatment Of Peptic Ulcers, Brandon Jerome Hinkel Jun 2013

Microcapsule Containing Lactic Acid Bacteria For Treatment Of Peptic Ulcers, Brandon Jerome Hinkel

Master's Theses

Probiotics are marketed throughout the world to promote the health of the consumer by improving the microorganisms that normally occur in the intestinal tract (Tannock, 1997). It has also been suggested that probiotics can prevent pathogen infections by adhering to the intestinal mucosa (Lee, Lim, Teng, Ouwehand, Tuomola, & Salminen, 2000). While probiotics can be delivered to the infected areas in multiple fashions, microencapsulation is a newer form of delivering probiotics straight to the infected area. A whey protein microcapsule is thought to protect the probiotics from stomach acid and delivers the treatment to the affected area. To ensure this …


Tracking Points On A Pacing Lead In A Beating Heart, Avinash Ramesh Varma Jun 2013

Tracking Points On A Pacing Lead In A Beating Heart, Avinash Ramesh Varma

Master's Theses

Heart failure is a common condition during which the pumping action of the heart is affected because the heart does not contract or relax properly. Heart failure affects about 5 million Americans, with 550,000 new cases diagnosed each year. Cardiac resynchronization therapy (CRT) is used to treat symptoms and other complications associated with a heart failure. While performing CRT, Implantation of a pacing lead in the left ventricle of the heart is a very challenging surgical procedure performed with fluoroscopy. The target location is often difficult to reach through the tortuous coronary venous anatomy, which varies greatly among individuals. Placement …


On The Development Of A Dynamic Contrast-Enhanced Near-Infrared Technique To Measure Cerebral Blood Flow In The Neurocritical Care Unit, Jonathan T. Elliott May 2013

On The Development Of A Dynamic Contrast-Enhanced Near-Infrared Technique To Measure Cerebral Blood Flow In The Neurocritical Care Unit, Jonathan T. Elliott

Electronic Thesis and Dissertation Repository

A dynamic contrast-enhanced (DCE) near-infrared (NIR) method to measure cerebral blood flow (CBF) in the neurocritical care unit (NCU) is described. A primary concern in managing patients with acquired brain injury (ABI) is onset of delayed ischemic injury (DII) caused by complications during the days to weeks following the initial insult, resulting in reduced CBF and impaired oxygen delivery.

The development of a safe, portable, and quantitative DCE-NIR method for measuring CBF in NCU patients is addressed by focusing on four main areas: designing a clinically compatible instrument, developing an appropriate analytical framework, creating a relevant ABI animal model, and …


Study Of Immobilizing Cadmium Selenide Quantum Dots In Selected Polymers For Application In Peroxyoxalate Chemiluminescence Flow Injection Analysis, Christopher S. Moore May 2013

Study Of Immobilizing Cadmium Selenide Quantum Dots In Selected Polymers For Application In Peroxyoxalate Chemiluminescence Flow Injection Analysis, Christopher S. Moore

Electronic Theses and Dissertations

Two batches of CdSe QDs with different sizes were synthesized for immobilizing in polyisoprene (PI), polymethylmethacrylate (PMMA), and low-density polyethylene (LDPE). The combinations of QDs and polymer substrates were evaluated for their analytical fit-for-use in applicable immunoassays. Hydrogen peroxide standards were injected into the flow injection analyzer (FIA) constructed to simulate enzyme-generated hydrogen peroxide reacting with bis-(2,4,6-trichlorophenyl) oxalate.

Linear correlations between hydrogen peroxide and chemilumenscent intensities yielded regression values greater than 0.9750 for hydrogen peroxide concentrations between 1.0 x 10-4 M and 1.0 x 10-1 M. The developed technique’s LOD was approximately 10 ppm. Variability of the prepared …


Delayed Thrombus Resolution And Fibroproliferative Vascular Wound Healing From Deficiency Of Type Iii Collagen: A Paradoxical Mechanism For Tissue Fragility, Amy J. Reid May 2013

Delayed Thrombus Resolution And Fibroproliferative Vascular Wound Healing From Deficiency Of Type Iii Collagen: A Paradoxical Mechanism For Tissue Fragility, Amy J. Reid

Dissertations & Theses (Open Access)

Vascular Ehlers-Danlos syndrome is a heritable disease of connective tissue caused by mutations in COL3A1, conferring a tissue deficiency of type III collagen. Cutaneous wounds heal poorly in these patients, and they are susceptible to spontaneous and catastrophic rupture of expansible hollow organs like the gut, uterus, and medium-sized to large arteries, which leads to premature death. Although the predisposition for organ rupture is often attributed to inherent tissue fragility, investigation of arteries from a haploinsufficient Col3a1 mouse model (Col3a1+/-) demonstrates that mutant arteries withstand even supraphysiologic pressures comparably to wild-type vessels. We hypothesize that injury …


Toward Characterization Of Diseased Vascular Structures Using Noncontact Photoacoustic And Laser-Ultrasound Imaging: A Phantom Study, Jami Lynne Johnson May 2013

Toward Characterization Of Diseased Vascular Structures Using Noncontact Photoacoustic And Laser-Ultrasound Imaging: A Phantom Study, Jami Lynne Johnson

Boise State University Theses and Dissertations

Visualizing and characterizing atherosclerotic plaques is important in determining the vulnerability of a plaque to rupture. To evaluate rupture risk, several compositional factors should be evaluated, including inflammation, the presence and size of lipid pools, thickness of the fibrous cap, and calcification. Currently, a need exists for an imaging modality that can detect each of these factors in a safe, noninvasive manner with high resolution and contrast at clinically relevant depths. Photoacoustic imaging is a growing field that has the potential to improve plaque diagnosis. Spectroscopic methods have shown promise toward detection of constituents of plaque with unique optical absorption …


A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll Mar 2013

A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll

Biomedical Engineering

Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …


Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen Jan 2013

Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen

Master's Theses

Malaria has profoundly influenced human history for over four thousand years and despite numerous attempts at eradication, the prevention, diagnosis, and treatment of malaria have been largely ineffective. More than five hundred million people are affected by malaria every year resulting in over one million deaths. Drug resistance development by the parasite has diminished the effectiveness of numerous treatment options due, in part, to overtreatment of negative patients based on insufficient clinical algorithms and diagnostic methods. The goal of this research was to develop an image analysis algorithm to diagnose malaria with a high degree of sensitivity and specificity in …


Visual Exploration And Information Analytics Of High-Dimensional Medical Images, Darshan Pai Jan 2013

Visual Exploration And Information Analytics Of High-Dimensional Medical Images, Darshan Pai

Wayne State University Dissertations

Data visualization has transformed how we analyze increasingly large and complex data sets. Advanced visual tools logically represent data in a way that communicates the most important information inherent within it and culminate the analysis with an insightful conclusion. Automated analysis disciplines - such as data mining, machine learning, and statistics - have traditionally been the most dominant fields for data analysis. It has been complemented with a near-ubiquitous adoption of specialized hardware and software environments that handle the storage, retrieval, and pre- and postprocessing of digital data. The addition of interactive visualization tools allows an active human participant in …


The Role Of Tissue Sound Speed As A Surrogate Marker Of Breast Density, Mark Sak Jan 2013

The Role Of Tissue Sound Speed As A Surrogate Marker Of Breast Density, Mark Sak

Wayne State University Dissertations

Breast density is one of the strongest predictors of breast cancer risk as women with the densest breasts have a three- to five-fold increase in risk compared to women with the least dense breasts. Breast density is currently measured by using mammography, the current gold standard for breast imaging. There are many shortcomings to using mammography to measure breast density, including the use of ionizing radiation. Ultrasound tomography (UST) does not use ionizing radiation and can create tomographic breast sound speed images. These sound speed images are useful because breast density is proportional to sound speed. The purpose of this …


Compressed Sensing And Joint Acquisition Techniques In Mri, Rouhollah Hamtaei Jan 2013

Compressed Sensing And Joint Acquisition Techniques In Mri, Rouhollah Hamtaei

Wayne State University Theses

The relatively long scan times in Magnetic Resonance Imaging (MRI) limits some clinical applications and the ability to collect more information in a reasonable period of time. Practically, 3D imaging requires longer acquisitions which can lead to a reduction in image quality due to motion artifacts, patient discomfort, increased costs to the healthcare system and loss of profit to the imaging center. The emphasis in reducing scan time has been to a large degree through using limited k-space data acquisition and special reconstruction techniques. Among these approaches are data extrapolation methods such as "constrained reconstruction" techniques, data interpolation methods such …


Noninvasive Near-Infrared Diffuse Optical Monitoring Of Cerebral Hemodynamics And Autoregulation, Ran Cheng Jan 2013

Noninvasive Near-Infrared Diffuse Optical Monitoring Of Cerebral Hemodynamics And Autoregulation, Ran Cheng

Theses and Dissertations--Biomedical Engineering

Many cerebral diseases are associated with abnormal cerebral hemodynamics and impaired cerebral autoregulation (CA). CA is a mechanism to maintain cerebral blood flow (CBF) stable when mean arterial pressure (MAP) fluctuates. Evaluating these abnormalities requires direct measurements of cerebral hemodynamics and MAP. Several near-infrared diffuse optical instruments have been developed in our laboratory for hemodynamic measurements including near-infrared spectroscopy (NIRS), diffuse correlation spectroscopy (DCS), hybrid NIRS/DCS, and dual-wavelength DCS flow-oximeter. We utilized these noninvasive technologies to quantify CBF and cerebral oxygenation in different populations under different physiological conditions/manipulations. A commercial finger plethysmograph was used to continuously monitor MAP. For investigating …


Recovering Local Neural Tract Directions And Reconstructing Neural Pathways In High Angular Resolution Diffusion Mri, Ning Cao Jan 2013

Recovering Local Neural Tract Directions And Reconstructing Neural Pathways In High Angular Resolution Diffusion Mri, Ning Cao

Theses and Dissertations--Computer Science

Magnetic resonance imaging (MRI) is an imaging technique to visualize internal structures of the body. Diffusion MRI is an MRI modality that measures overall diffusion effect of molecules in vivo and non-invasively. Diffusion tensor imaging (DTI) is an extended technique of diffusion MRI. The major application of DTI is to measure the location, orientation and anisotropy of fiber tracts in white matter. It enables non-invasive investigation of major neural pathways of human brain, namely tractography. As spatial resolution of MRI is limited, it is possible that there are multiple fiber bundles within the same voxel. However, diffusion tensor model is …


Significance And Analysis Of Milia-Like Cysts In Dermoscopy Skin Lesion Images, Sneha K. Mahajan Jan 2013

Significance And Analysis Of Milia-Like Cysts In Dermoscopy Skin Lesion Images, Sneha K. Mahajan

Masters Theses

“Milia-like cysts (MLCs) are dermoscopic structures frequently observed in seborrheic keratoses(SKs), which are the most common type of skin lesions. Diverse appearances of these skin lesions make them difficult to differentiate from melanoma, a deadly type of skin cancer. Classified by size into two main groups, starry MLCs and cloudy MLCs, the presence of these structures in a skin lesion has been known to help differentiate benign lesions from melanoma. Though the presence of cloudy MLCs is not exclusively associated with SKs, they can be a useful tool to differentiate SKs from melanoma. This research study determines the statistical occurrence …


Automatic Detection Of Polypoid Skin Lesions: The Squash Sign, Saurabh G. Karnik Jan 2013

Automatic Detection Of Polypoid Skin Lesions: The Squash Sign, Saurabh G. Karnik

Masters Theses

“Earlier detection of malignant melanoma can save lives. Automatic in-vivo methods of melanoma detection including smart-phone applications are now available, but specificity is low, i.e. too many benign lesions are detected as possible melanomas. Polypoids, elevated and rounded lesions are one class of benign lesions. These raised lesions with piecewise circular borders, predominantly intradermal nevi and cutaneous polyps (IDNs), are always benign. Variegated coloring present in polypoid lesions can lead physicians to perform an unneeded biopsy. Contact dermatoscope plates with gel squash these lesions, leaving a “squash sign” marker of benignancy which can be automatically detected. We present a method …