Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 13 of 13

Full-Text Articles in Biomedical Engineering and Bioengineering

Nanomaterial-Based Biosensors For Detection Of Salmonella Typhimurium And Avian Influenza Virus H5n1 In Poultry, Xinge Xi Jul 2021

Nanomaterial-Based Biosensors For Detection Of Salmonella Typhimurium And Avian Influenza Virus H5n1 In Poultry, Xinge Xi

Graduate Theses and Dissertations

This research focused on developing biosensing method and biosensing device for rapid detection of pathogens in poultry: Salmonella Typhimurium and avian influenza virus H5N1. The first part of the dissertation reports an original research on the development of a portable biosensing device for Salmonella detection. The device was designed and constructed based on a previously developed optical biosensing method, using immuno-magnetic nanoparticles to specifically capture target bacteria, and immuno-quantum dot beads to label the target bacteria for fluorescence detection. All the actions of sample mixing, magnetic separation, and fluorescence detection were controlled automatically in a disposable microfluidic chip in the …


Redesign And Quantitative Assessment Of An Accelerated Venous Valve Fatigue Apparatus, Megan Kueh May 2020

Redesign And Quantitative Assessment Of An Accelerated Venous Valve Fatigue Apparatus, Megan Kueh

Biomedical Engineering Undergraduate Honors Theses

Chronic venous insufficiency (CVI) is a form of cardiovascular disease that is caused when valves in the leg become incompetent. Current treatment methods serve to manage symptoms, but there are currently no ways to treat the underlying cause of CVI. A venous valve prosthetic made from a xenograft of a bovine jugular vein is one possible treatment method currently in the research phase. Prosthetic valves must be tested with an accelerated wear tester prior to approval for clinical testing. Although such testers exist for heart valves, physiological differences between heart and venous valves restrict the use those testers on venous …


Modified Stent Design For A Coronary Bifurcation Lesion, Abigail Nowell May 2020

Modified Stent Design For A Coronary Bifurcation Lesion, Abigail Nowell

Biological Sciences Undergraduate Honors Theses

Currently, 18.2 million adults aged 20 and older are diagnosed with Coronary Artery Disease (CAD) (Benjamin et al., 2019). Stenosis is the most common intervention. However, when a patient has a bifurcated artery, treatment becomes more difficult and is often unsuccessful. This project created a new stent and balloon complex that was tested in vitro using a gel phantom artery model. Two separate prototypes have been created and tested so far, with improvements made upon each. Testing is still underway with Prototype 2.


Visualizing Ischemic Skin Flap Necrosis Through Phasor Analysis Of Autofluorescence Lifetime Images, Hallie Ramser Toomer Aug 2019

Visualizing Ischemic Skin Flap Necrosis Through Phasor Analysis Of Autofluorescence Lifetime Images, Hallie Ramser Toomer

Graduate Theses and Dissertations

Necrotic skin flaps are difficult to predict and treat due to the lack of quantitative biomarkers. Label-free multiphoton microscopy is well suited for non-invasively monitoring skin metabolism through NAD(P)H and other intrinsic fluorophores, and offers immediate future directions for assessing necrosis in the clinic. The objective of this study was to assess whether phasor FLIM could be used to evaluate skin flap status and treatment efficacy in ex vivo skin sections. Phasor maps revealed differences in growth factor treatment and region, but changes in skin flap autofluorescence at 755nm excitation and 460nm emission were not just related to NAD(P)H. A …


Investigating Virus Clearance Via Ph Inactivation During Biomanufacturing, Wenbo Xu May 2019

Investigating Virus Clearance Via Ph Inactivation During Biomanufacturing, Wenbo Xu

Biomedical Engineering Undergraduate Honors Theses

In the processing of biopharmaceuticals, viral clearance and viral safety are important for the development of monoclonal antibodies. Murine xenotropic leukemia virus (XMuLV) is one of the retroviruses, recommended by Food and Drug Administration (FDA) as a model virus for viral clearance via inactivation from therapeutics derived from Chinese hamster ovary cells (CHO). A robust and effective method was investigated to clear or inactivate endogenous viruses by low pH inactivation. The effects of different conductivity and inactivated time on XMuLV clearance was determined. Acetate buffer was prepared with different conductivity, and 2% XMuLV was spiked into acetate buffer. XMuLV virus …


Extraction And Analysis Of Vector Flow Imaging Data In A Pediatric Population, Bailey Stinnett May 2018

Extraction And Analysis Of Vector Flow Imaging Data In A Pediatric Population, Bailey Stinnett

Biomedical Engineering Undergraduate Honors Theses

Vector flow imaging (VFI) is a new ultrasound technology that provides real time, angle-independent visualization of flow velocities in the heart and great vessels. Thus far, VFI has been used for superficial applications due to the limited penetration depth of available transducer probes; however, this depth in smaller pediatric patients enables adequate aortic views. In this project, VFI was used to study pediatric aortic stenosis (PAS)—a congenital heart defect that results in the narrowing of the aorta and/or aortic valve. The decision to refer PAS patients for surgical or catheter-based intervention is initially based on Doppler ultrasound. VFI is potentially …


In-Vitro Simulation Of Acute Ischemic Stroke, Paolo Garcia May 2018

In-Vitro Simulation Of Acute Ischemic Stroke, Paolo Garcia

Biomedical Engineering Undergraduate Honors Theses

Acute ischemic stroke (AIS) is a condition that involves the occlusion of a blood vessel within the brain, effectively preventing the passage of oxygen and nutrients. AIS is highly prevalent in the United States, where nearly 795,000 strokes happen per year and 87% of those are ischemic. From a medical standpoint, the obstructing clot can be removed with the use of a stroke retrieval device. However, a need arises for testing the aforementioned devices on a patient’s specific vascular geometries in order to increase the likelihood of a successful procedure. Outlined is a process for developing a physical simulation of …


Characterization Of Murine Breast Cancer Cell Lines For Anti-Cancer Vaccine, Haven N. Frazier May 2017

Characterization Of Murine Breast Cancer Cell Lines For Anti-Cancer Vaccine, Haven N. Frazier

Biological Sciences Undergraduate Honors Theses

Breast cancer is the most commonly diagnosed cancer in women and the second leading cause of cancer death among women in the United States (1). While treatments involving radiation and chemotherapy currently exist, disease must be detected early in order for the treatments to be somewhat effective, and there is no effective treatment after metastasis occurs (2). Additionally, current therapies do not mitigate tumor immunosuppression. Decreasing the tumor-associated immunosuppressive conditions while activating antitumor immunity could prevent recurrence and metastasis, possibly leading to an effective treatment for cancer (3). Tumor cell vaccines could possibly address this issue and have become a …


Micellular Electrokinetic Chromatography For Studying Amyloid Beta Oligomer Membrane Affinity, Andrew Bryson May 2016

Micellular Electrokinetic Chromatography For Studying Amyloid Beta Oligomer Membrane Affinity, Andrew Bryson

Biomedical Engineering Undergraduate Honors Theses

Amyloid Beta (Aβ) was the major focus of this study. It is a peptide that is present in the brain with a high tendency to self-aggregate. When this protein aggregates, it forms oligomers and protofibrils which in turn are deposited as senile plaques in the brain. The reason for the concern with these plaques is their association with the neurological disorder Alzheimer’s disease. It has been found that the most dangerous oligomers are formed in a portion of the plasma membrane known as lipid rafts. The purpose of this study was to understand how micelles affect the aggregation properties of …


Multiplexed Loop-Mediated Isothermal Amplification Of The 16s Rrna Gene For The Diagnosis Of Neonatal Sepsis In Resource-Limited Environments, Griffin T. Sonaty Jan 2015

Multiplexed Loop-Mediated Isothermal Amplification Of The 16s Rrna Gene For The Diagnosis Of Neonatal Sepsis In Resource-Limited Environments, Griffin T. Sonaty

Inquiry: The University of Arkansas Undergraduate Research Journal

Sepsis, or dysregulated inflammation caused by bacterial infection, places a disproportionately high burden on newborns in developing countries. This is due in part to a lack of diagnostic tools suitable for sustainable use in resource-limited nurseries. One potential vehicle for a new diagnostic assay is loop-mediated isothermal amplification (LAMP), a high-yield DNA amplification method. LAMP has previously been used to detect genes from single species of bacteria in blood serum samples to aid in sepsis diagnosis. LAMP could be adapted to detect a broad set of bacteria, while retaining a degree of specificity that allows clinicians to begin directed antimicrobial …


Hybrid Nanostructured Textile Bioelectrode For Unobtrusive Health Monitoring, Pratyush Rai Aug 2013

Hybrid Nanostructured Textile Bioelectrode For Unobtrusive Health Monitoring, Pratyush Rai

Graduate Theses and Dissertations

Coronary heart disease, cardiovascular diseases and strokes are the leading causes of mortality in United States of America. Timely point-of-care health diagnostics and therapeutics for person suffering from these diseases can save thousands of lives. However, lack of accessible minimally intrusive health monitoring systems makes timely diagnosis difficult and sometimes impossible. To remedy this problem, a textile based nano-bio-sensor was developed and evaluated in this research. The sensor was made of novel array of vertically standing nanostructures that are conductive nano-fibers projecting from a conductive fabric. These sensor electrodes were tested for the quality of electrical contact that they made …


Design And Implementation Of Wireless Point-Of-Care Health Monitoring Systems: Diagnosis For Sleep Disorders And Cardiovascular Diseases, Se Chang Oh May 2013

Design And Implementation Of Wireless Point-Of-Care Health Monitoring Systems: Diagnosis For Sleep Disorders And Cardiovascular Diseases, Se Chang Oh

Graduate Theses and Dissertations

Chronic sleep disorders are present in 40 million people in the United States. More than 25 million people remain undiagnosed and untreated, which accounts for over $22 billion in unnecessary healthcare costs. In addition, another major chronic disease is the heart diseases which cause 23.8% of the deaths in the United States. Thus, there is a need for a low cost, reliable, and ubiquitous patient monitoring system. A remote point-of-care system can satisfy this need by providing real time monitoring of the patient's health condition at remote places. However, the currently available POC systems have some drawbacks; the fixed number …


Development Of A Microfluidic Device Coupled To Microdialysis Sampling For The Pre-Concentration Of Cytokines, Randy Francisco Espinal Cabrera May 2012

Development Of A Microfluidic Device Coupled To Microdialysis Sampling For The Pre-Concentration Of Cytokines, Randy Francisco Espinal Cabrera

Graduate Theses and Dissertations

A proof-of-concept microfluidic device combined with heparin-immobilized magnetic beads was created to concentrate cytokine proteins collected from microdialysis samples. Cytokines are known to be related to several diseases such as cancer, and Parkinson's diseases, so to be able to develop more effective diseases treatments their interactions have to be well understood. Amine-functionalized polystyrene and carboxyl-functionalized magnetic microspheres of ~6.0 ìm in diameter were used to immobilize heparin. The amount of heparin immobilized on polystyrene beads was 5.82 x 10-8 ± 0.36 x 10-8 M per 1.0 x 106 beads and for magnetic beads was 0.64 x 10-8 ± 0.01 x …