Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 27 of 27

Full-Text Articles in Biomedical Engineering and Bioengineering

List Of 121 Papers Citing One Or More Skin Lesion Image Datasets, Neda Alipour Jul 2023

List Of 121 Papers Citing One Or More Skin Lesion Image Datasets, Neda Alipour

Other resources

No abstract provided.


High-Sensitivity Vector Bend Sensor Based On A Fiber Directional Coupler Inscribed By A Femtosecond Laser, Ke Tian, Mingyuan Zhang, Chuanzhein Zhao, Huibin Li, Shilong Li, Yuxuan Jiang, Gerald Farrell, Pengfei Wang Jan 2023

High-Sensitivity Vector Bend Sensor Based On A Fiber Directional Coupler Inscribed By A Femtosecond Laser, Ke Tian, Mingyuan Zhang, Chuanzhein Zhao, Huibin Li, Shilong Li, Yuxuan Jiang, Gerald Farrell, Pengfei Wang

Articles

In this Letter, we demonstrate a high-sensitivity vector bend sensor based on a fiber directional coupler. The fiber directional coupler is composed of two parallel waveguides inscribed within a no-core fiber (NCF) by a femtosecond laser. Since the two written waveguides have closely matched refractive indices and geometries, the transmission spectrum of the fiber directional coupler possesses periodic resonant dips. Such a fiber directional coupler exhibits a good bending-dependent spectral shift response due to its asymmetric structure. Experimental results show that bending sensitivities of -97.11 nm/m-1 and 58.22 nm/m-1 are achieved for the 0° and 180° orientations in the curvature …


A Label-Free Fiber Ring Laser Biosensor For Ultrahigh Sensitivity Detection Of Salmonella Typhimurium, Shi Qiu, Bin Liu, Yuankui Leng, Edward Fox, Xian Zhou, Binbin Yan, Xinzhu Sang, Long Long, Xingdao He, Jinhui Yuan, Gerald Farrell, Qiang Wu Jan 2023

A Label-Free Fiber Ring Laser Biosensor For Ultrahigh Sensitivity Detection Of Salmonella Typhimurium, Shi Qiu, Bin Liu, Yuankui Leng, Edward Fox, Xian Zhou, Binbin Yan, Xinzhu Sang, Long Long, Xingdao He, Jinhui Yuan, Gerald Farrell, Qiang Wu

Articles

The rapid detection of low concentrations of Salmonella Typhimurium (S. Typhimurium) is an essential preventive measure for food safety and prevention of foodborne illness. The study presented in this paper addresses this critical issue by proposing a single mode-tapered seven core-single mode (STSS) fiber ring laser (FRL) biosensor for S. Typhimurium detection. The experimental results show that the specific detection time of S. Typhimurium is less than 20 min and the wavelength shift can achieve -0.906 nm for an S. Typhimurium solution (10 cells/mL). Furthermore, at a lower concentration of 1 cell/mL applied to the biosensor, a result of -0.183 …


A Robust Lpc Filtering Method For Time-Resolved Morphology Of Eeg Activity Analysis, Jin Xu, Mark Davis, Ruairí De Fréin Jan 2020

A Robust Lpc Filtering Method For Time-Resolved Morphology Of Eeg Activity Analysis, Jin Xu, Mark Davis, Ruairí De Fréin

Conference Papers

This paper introduces a new time-resolved spectral analysis method based on Linear Prediction Coding (LPC) method that is particularly suited to the study of the dynamics of EEG (Electroencephalogram) activity. The spectral dynamic of EEG signals can be challenging to analyse as they contain multiple frequency components and are often heavily corrupted by noise. Furthermore, the temporal and spectral resolution that can be achieved is limited by the Heisenberg-Gabor uncertainty principle [1]. The method described here is based on a z-plane analysis of the poles of the LPC which allows us to identify and estimate the frequency of the dominant …


Identification Of Unique Features And Exploration Of Leap Motion Controller For Detecting Hand Hygiene Stages, Rashmi Bakshi, Jane Courtney, Damon Berry, Graham Gavin Jan 2018

Identification Of Unique Features And Exploration Of Leap Motion Controller For Detecting Hand Hygiene Stages, Rashmi Bakshi, Jane Courtney, Damon Berry, Graham Gavin

Conference Papers

Hospital acquired infections (HAIs) are contracted by the patients during the hospital stay. Antibiotic resistant microbes are the major cause and spread due to the contaminated medical equipment, crowded hospitals, frequent transfer of patients from one unit to another and poor hand hygiene. [1] In high income countries, approximately 30% of patients in intensive care units are affected by at least one HAI. [2] Hand hygiene is identified as a measure to prevent cross-transmission and to reduce the rate of HAI. [3] Technology is now used as a means of assessing hand hygiene compliance. Current approaches involve the use of …


Breast Cancer Detection Using Interferometric Music: Experimental And Numerical Assessment, Giuseppe Ruvio, Raffaele Solimene, Antonio Cuccaro, Domenico Gaetano, Jacinta Browne, Max Ammann Sep 2014

Breast Cancer Detection Using Interferometric Music: Experimental And Numerical Assessment, Giuseppe Ruvio, Raffaele Solimene, Antonio Cuccaro, Domenico Gaetano, Jacinta Browne, Max Ammann

Articles

Purpose: In microwave breast cancer detection, it is often beneficial to arrange sensors in close proximity to the breast. The resultant coupling generally changes the antenna response. As an a priori characterization of the radio frequency system becomes difficult, this can lead to severe degradation of the detection efficacy. The purpose of this paper is to demonstrate the advantages of adopting an interferometric multiple signal classification (I-MUSIC) approach due to its limited dependence from a priori information on the antenna. The performance of I-MUSIC detection was measured in terms of signal-to-clutter ratio (SCR), signal-to-mean ratio (SMR), and spatial displacement (SD) …


Quantized Nonnegative Matrix Factorization, Ruairí De Fréin Jan 2014

Quantized Nonnegative Matrix Factorization, Ruairí De Fréin

Conference papers

Even though Nonnegative Matrix Factorization (NMF) in its original form performs rank reduction and signal compaction implicitly, it does not explicitly consider storage or transmission constraints. We propose a Frobenius-norm Quantized Nonnegative Matrix Factorization algorithm that is 1) almost as precise as traditional NMF for decomposition ranks of interest (with in 1-4dB), 2) admits to practical encoding techniques by learning a factorization which is simpler than NMF’s (by a factor of 20-70) and 3) exhibits a complexity which is comparable with state-of-the-art NMF methods. These properties are achieved by considering the quantization residual via an outer quantization optimization step, in …


Multimodal Wearable Sensors For Human-Machine Interfaces, Mark Nolan Aug 2013

Multimodal Wearable Sensors For Human-Machine Interfaces, Mark Nolan

Doctoral

Certain areas of the body, such as the hands, eyes and organs of speech production, provide high-bandwidth information channels from the conscious mind to the outside world. The objective of this research was to develop an innovative wearable sensor device that records signals from these areas more conveniently than has previously been possible, so that they can be harnessed for communication. A novel bioelectrical and biomechanical sensing device, the wearable endogenous biosignal sensor (WEBS), was developed and tested in various communication and clinical measurement applications.

One ground-breaking feature of the WEBS system is that it digitises biopotentials almost …


Footwear-Centric Body Area Network With Directional Uwb Antenna, Domenico Gaetano, Vit Sipal, Patrick Mcevoy, Max Ammann, C Brannigan, Louise Keating, Frances Horgan Jul 2013

Footwear-Centric Body Area Network With Directional Uwb Antenna, Domenico Gaetano, Vit Sipal, Patrick Mcevoy, Max Ammann, C Brannigan, Louise Keating, Frances Horgan

Articles

A footwear-centric body area network employing a directional antenna is compared with waist-centric systems using omnidirectional and directional antennas. The impact of body movements on path gain is analysed for two bands at 3.99 GHz and 7.99 GHz. The path gain and data rate results demonstrate that footwear-centric configurations are equivalent or better than waist-centric body area networks.


Comparison Of Non-Coherent Linear Breast Cancer Detection Algorithms Applied To A 2-D Numerical Breast Model, Giuseppe Ruvio, Raffaele Solimene, Antonio Cuccaro, Max Ammann Jan 2013

Comparison Of Non-Coherent Linear Breast Cancer Detection Algorithms Applied To A 2-D Numerical Breast Model, Giuseppe Ruvio, Raffaele Solimene, Antonio Cuccaro, Max Ammann

Articles

A comparative analysis of an imaging method based on a multi-frequency Multiple Signal Classification (MUSIC) approach against two common linear detection algorithms based on non-coherent migration is made. The different techniques are tested using synthetic data generated through CST Microwave Studio and a phantom developed from MRI scans of a mostly fat breast. The multi-frequency MUSIC approach shows an overall superior performance compared to the non-coherent techniques. This paper reports that this highly performing algorithm does not require any antenna calibration or phase response estimation and allows the use of efficient and complex antenna geometries without difficult algorithm redefinitions.


A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle Jun 2012

A Wireless And Digital Electrode Bus Topology For Biopotential Measurement, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

The conventional biopotential measurement configuration utilises long lead wires which connect measuring electrodes to signal conditioning circuitry. The majority of bioelectric signals that are measured from the human body have a tiny signal amplitude (5µV-5mV range) and thus any interference that is induced on the lead wires can have a detrimental effect on the original signal. In this paper, we present an alternative configuration, in which digitisation occurs on the electrode, potentially providing enhanced signal measurement as well as significant benefits in terms of the simplification of the physical interconnections between electrodes. Multiple electrodes are combined to form a digital …


The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle Apr 2012

The Presence Of Regional Accents In Electrolarynx Speech And The Resultant Effect On Overall Intelligibility., Brian Madden, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, a phonological analysis of a section of results from an online perceptual intelligibility test was performed which compared speech produced using a novel hands-free electrolarynx and a commercially available electrolarynx. A portion of the test consisted of a closed-set format containing a selection of four sets of four random CVC audio samples …


Radio-Frequency Breast Cancer Imaging Results For A Simplified Cylindrical Phantom, Giuseppe Ruvio, Raffaele Solimene, Antonietta D'Alterio, Max Ammann, Rocco Pierri Feb 2011

Radio-Frequency Breast Cancer Imaging Results For A Simplified Cylindrical Phantom, Giuseppe Ruvio, Raffaele Solimene, Antonietta D'Alterio, Max Ammann, Rocco Pierri

Conference Papers

Microwave imaging is a pervasive research field and
is useful in numerous applicative diagnostic noninvasive contexts. This paper focuses on two aspects. First, we perform a numerical investigation to assess the role played by fundamental parameters (i.e. number of sensors, operating frequency bandwidth) on cancer detection. To this end, a simplified cylindrical phantom probed by ideal two-dimensional dipoles (i.e. infinitely long along the axis of invariance) is considered. Second, in order to focus on the role of the antennas, we analyze, still by numerical simulations and for a simplified breast model, how performances vary when a realistic antenna is adopted.


Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle Jan 2011

Novel Bioelectrical Measurement Using A Digital Biopotential Monode, Mark Nolan, Edward Burke, Eugene Coyle

Conference Papers

In conventional biopotential recording, two or more electrodes are placed on the body. A unipolar lead records the time-varying electrical potential at a single point (relative to a reference potential) via one signal electrode. A bipolar lead records the time-varying potential difference between two points via two signal electrodes. In each case, the signal electrodes are connected to high impedance amplifier inputs, while an additional electrode provides a low-impedance path between the amplifier and human subject. Bipolar leads are usually preferred since interference appearing at both signal electrodes can be eliminated using an instrumentation amplifier with high CMRR. A drawback …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle Jan 2011

Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …


In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen Jan 2011

In-Silico Hyperthermia Performance Of A Near-Field Patch Antenna At Various Positions On A Human Body Model, Sergio Curto, Terrence See, Patrick Mcevoy, Max Ammann, Zhi Ning Chen

Articles

A compact patch applicator designed to enhance targeted energy coupling at 434 MHz is a key enabler for sensitizing temperature increments in body regions containing superficial tumours. A detailed FDTD body model is used to explore simulated RF coupling and temperature increments for typical clinical conditions. The antenna impedance matching, specific absorption rate and thermal distribution parameters are evaluated to identify applied performance outcomes. The analysis reveals physiological-RF coupling patterns for an optimised closely-coupled single element applicator.


On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle Jan 2011

On Improving Electrooculogram-Based Computer Mouse Systems: The Accelerometer Trigger, Johnalan Keegan, Edward Burke, James Condron, Eugene Coyle

Conference Papers

Eye tracking is a well-established method of computer control for profoundly paralysed people (Anson et al., 2002). Cameras are commonly used to track eye movements (Morimoto et al., 2005) but one alternative is the bioelectrical signal known as the electrooculogram (EOG). There are some EOG mouse control systems that facilitate the use of GUI applications, but certain actions, which are straightforward using a conventional mouse, remain impossible. Unless the eyes are tracking a target, they move in saccades (jumps), making it impossible to voluntarily trace out smooth trajectories with one's gaze, as would be required to draw a smooth curve. …


A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor Aug 2010

A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi M. De Paor

Articles

This paper presents a new, user-friendly, portable motion capture and gait analysis system for capturing and analyzing human gait, designed as a telemedicine tool to monitor remotely the progress of patients through treatment. The system requires minimal user input and simple single-camera filming (which can be acquired from a basic webcam) making it very accessible to nontechnical, nonclinical personnel. This system can allow gait studies to acquire a much larger data set and allow trained gait analysts to focus their skills on the interpretation phase of gait analysis. The design uses a novel motion capture method derived from spatiotemporal segmentation …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li, Damon Berry, Richard Hayes Jan 2009

A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li, Damon Berry, Richard Hayes

Conference Papers

Preventative health management represents a shift from the traditional approach of reactive treatment-based healthcare towards a proactive wellness-management approach where patients are encouraged to stay healthy with expert support when they need it, at any location and any time. This work represents a step along the road towards proactive, preventative healthcare for cardiac patients. It seeks to develop a smart mobile ECG monitoring system that requests and records context information about what is happening around the subject when an arrhythmia event occurs. Context information about the subject’s activities of daily living will, it is hoped, provide an enriched data set …


A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li Jan 2008

A Mobile Ecg Monitoring System With Context Collection, Jin Peng Li

Masters

An objective of a health process is one where patients can stay healthy with the support of expert medical advice when they need it, at any location and any time. An associated aim would be the development of a system which places increased emphasis on preventative measures as a first point of contact with the patient. This research is a step along the road towards this type of preventative healthcare for cardiac patients. It seeks to develop a smart mobile ECG monitoring system that requests and records context information about what is happening around the subject when an arrhythmia event …


Electric-Powered Wheelchairs As An Assistive Technology, Aidan O'Dwyer, Malabika Basu, Eugene Coyle Jan 2008

Electric-Powered Wheelchairs As An Assistive Technology, Aidan O'Dwyer, Malabika Basu, Eugene Coyle

Conference papers

This paper briefly outlines recent work done, particularly in control systems, for electric powered wheelchairs. These mobility aids, first developed in the 1950’s [1], were improved with the incorporation of microprocessors. The requirement for mobility aids in general is rising; for example, it is reckoned that 1.5% of the U.K. population require such aids. As an assistive technology, electric powered wheelchairs have many benefits. Nevertheless, a reliable and robust such wheelchair has still to evolve.


Preliminary Results For A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi Depaor May 2006

Preliminary Results For A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi Depaor

Articles

This paper presents results from a novel monocular marker-free gait measurement system. The system was designed for physical and occupational therapists to monitor the progress of patients through therapy. It is based on a novel human motion capture method derived from model-based tracking. Testing is performed on two monocular, sagittal-view, sample gait videos – one with both the environment and the subject’s appearance and movement restricted and one in a natural environment with unrestricted clothing and motion. Results of the modelling, tracking and analysis stages are presented along with standard gait graphs and parameters.


Controlled Braking Scheme For A Wheeled Walking Aid, Eugene Coyle, Aidan O'Dwyer, Eileen Young, Kevin Sullivan, A. Toner Jan 2006

Controlled Braking Scheme For A Wheeled Walking Aid, Eugene Coyle, Aidan O'Dwyer, Eileen Young, Kevin Sullivan, A. Toner

Conference papers

A wheeled walking aid with an embedded controlled braking system is described. The frame of the prototype is based on combining features of standard available wheeled walking aids. A braking scheme has been designed using hydraulic disc brakes to facilitate accurate and sensitive controlled stopping of the walker by the user, and if called upon, by automatic action. Braking force is modulated via a linear actuating stepping motor. A microcontroller is used for control of both stepper movement and for supervisory control. An encoder is used to supervise walker movement in terms of time, distance and speed.


Synthesising Life-Sciences And Control Engineering: An Outline Survey And A Practical Example, Aidan O'Dwyer Jan 2006

Synthesising Life-Sciences And Control Engineering: An Outline Survey And A Practical Example, Aidan O'Dwyer

Conference papers

There is an increasing interest in life science related areas in the electrical and control engineering community [1]. One manifestation of this interest is the development of interdisciplinary programmes, such as the B.Sc. in Medical Physics and Bioengineering, offered by the Dublin Institute of Technology from September 2005. A significant amount of research work in control engineering has focused on aspects of human physiological system, for example blood glucose regulation [2], cardiovascular modelling and control [3], and limb control [4]. There is an increasing emphasis on interdisciplinary research; in recognition of this, the Institute of Electrical Engineers (IEE) has starting …


A Vocalisation-Based Drawing Interface For Disabled Children, Ted Burke May 2004

A Vocalisation-Based Drawing Interface For Disabled Children, Ted Burke

Articles

In our work with disabled children at Ireland’s National Rehabilitation Hospital, a problem we have experienced in the facilitation of art activities is that traditional art materials and standard computer drawing programs sometimes prove inaccessible. In this paper, an original system, called “PaintMyVoice” is presented which facilitates the creation of two or three-dimensional images using a variety of novel input modalities. In particular, vocalisations can be used to create original images of a variety of objects, including trees, flowers and landscape elements. Additional input to the system can optionally be provided via mouse, keyboard, switch interface or digital camera depending …