Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Biomedical Engineering and Bioengineering

Medical Dental Device: Biogeneric Implant Prototype, Ibeth Erazo, Aneeza Hussain, Renata Budny, Gaffar Gailani Oct 2019

Medical Dental Device: Biogeneric Implant Prototype, Ibeth Erazo, Aneeza Hussain, Renata Budny, Gaffar Gailani

Publications and Research

Teeth are lost due to tooth decay, injury, disease, or other causes. Today, dental implants extend the range of care to a variety of patients undergoing necessary prosthodontic rehabilitation. If the benefits of such treatments are to be maximized, then implants must be selected on logical basis and placed within the context of the full range of treatment modalities. However, modern dental implant systems are based on multiple components often leading to micro-movements which cause stress on the bone or bacterial infections, both of which compromise the success of osseointegration and consequently jeopardize the whole implant adaptation. Thus, a new …


The Influence Of The Electrode Dimension On The Detection Sensitivity Of Electric Cell–Substrate Impedance Sensing (Ecis) And Its Mathematical Modeling, Xudong Zhang, William Wang, Anis Nurashikin Nordin, Fang Li, Sunghoon Jang, Ioana Voiculescu Aug 2017

The Influence Of The Electrode Dimension On The Detection Sensitivity Of Electric Cell–Substrate Impedance Sensing (Ecis) And Its Mathematical Modeling, Xudong Zhang, William Wang, Anis Nurashikin Nordin, Fang Li, Sunghoon Jang, Ioana Voiculescu

Publications and Research

Detection sensitivity is a crucial criterion in the design and application of ECIS sensors. The influence of sensing electrode dimension on detection sensitivity is investigated in this paper. Eight types of ECIS sensors were fabricated, and their experimental results reveal that smaller-radius working electrodes generate more sensitive impedance shift to cell density change. Also, the smaller radius of working electrodes yield higher impedance values, which improves signal-to-noise ratio. In a range from 1.0 mm to 3.5 mm, the distance between the working and counter electrodes does not affect impedance measurements. However, the distance should be large enough to prevent the …


Contact Analysis For Coupling Of Plates And Screws In Fracture Fixation Of Cortical Bone, Gaffar Gailani, Rachid Moumni, Malek Brahimi Jan 2015

Contact Analysis For Coupling Of Plates And Screws In Fracture Fixation Of Cortical Bone, Gaffar Gailani, Rachid Moumni, Malek Brahimi

Publications and Research

Internal fixation is a common treatment for bone fracture. Bone fracture occurs due to different reasons such as motor vehicle accidents, falling,…etc. The treatment is performed by fixing plate and screws to the fracture site. Lack of stability of the implants (plates and screws) may lead to delay in healing or failure of treatment. Micro-motion between the implant and the bone may cause formation of fibrous tissue around the screw which will lead to implant loosening. On the other hands, firm fixing of the conventional implants (Dynamic Compression Plates) may lead to delay resorption and delay in healing. Recently, Locked …