The Influence Of The Electrode Dimension On The Detection Sensitivity Of Electric Cell–Substrate Impedance Sensing (Ecis) And Its Mathematical Modeling, Xudong Zhang, William Wang, Anis Nurashikin Nordin, Fang Li, Sunghoon Jang, Ioana Voiculescu Aug 2017

The Influence Of The Electrode Dimension On The Detection Sensitivity Of Electric Cell–Substrate Impedance Sensing (Ecis) And Its Mathematical Modeling, Xudong Zhang, William Wang, Anis Nurashikin Nordin, Fang Li, Sunghoon Jang, Ioana Voiculescu

Publications and Research

Detection sensitivity is a crucial criterion in the design and application of ECIS sensors. The influence of sensing electrode dimension on detection sensitivity is investigated in this paper. Eight types of ECIS sensors were fabricated, and their experimental results reveal that smaller-radius working electrodes generate more sensitive impedance shift to cell density change. Also, the smaller radius of working electrodes yield higher impedance values, which improves signal-to-noise ratio. In a range from 1.0 mm to 3.5 mm, the distance between the working and counter electrodes does not affect impedance measurements. However, the distance should be large enough to ...


Contact Analysis For Coupling Of Plates And Screws In Fracture Fixation Of Cortical Bone, Gaffar Gailani, Rachid Moumni, Malek Brahimi Jan 2015

Contact Analysis For Coupling Of Plates And Screws In Fracture Fixation Of Cortical Bone, Gaffar Gailani, Rachid Moumni, Malek Brahimi

Publications and Research

Internal fixation is a common treatment for bone fracture. Bone fracture occurs due to different reasons such as motor vehicle accidents, falling,…etc. The treatment is performed by fixing plate and screws to the fracture site. Lack of stability of the implants (plates and screws) may lead to delay in healing or failure of treatment. Micro-motion between the implant and the bone may cause formation of fibrous tissue around the screw which will lead to implant loosening. On the other hands, firm fixing of the conventional implants (Dynamic Compression Plates) may lead to delay resorption and delay in healing. Recently ...


Feasibility Analysis Of Estrification Systems With Entrainers, Kang Wook Lee Jan 2012

Feasibility Analysis Of Estrification Systems With Entrainers, Kang Wook Lee

Dissertations and Theses

(Ethyl Acetate) and IPA (Isopropyl Acetate) production systems are studied in terms of the feasibility analysis. It is not feasible to retrieve pure products by a simple reactive distillation for IPA production system because CCR (Critical Composition Region) covers the entire desired binary edge for IPA system. On the other hand, even though CCR does not cover the entire desired binary edge of the EA system completely, internal reflux ratio (IRR) analysis does not allow the production of the pure product via reactive distillation for EA production system. To overcome the restraints, external entrainers are utilized to take advantage of ...