Full-Text Articles in Biomedical Engineering and Bioengineering

Evaluation Of Drug-Loaded Gold Nanoparticle Cytotoxicity As A Function Of Tumor Tissue Heterogeneity., Hunter Allan Miller Aug 2018

Evaluation Of Drug-Loaded Gold Nanoparticle Cytotoxicity As A Function Of Tumor Tissue Heterogeneity., Hunter Allan Miller

Electronic Theses and Dissertations

The inherent heterogeneity of tumor tissue presents a major challenge to nanoparticle-medicated drug delivery. This heterogeneity spans from the molecular to the cellular (cell types) and to the tissue (vasculature, extra-cellular matrix) scales. Here we employ computational modeling to evaluate therapeutic response as a function of vascular-induced tumor tissue heterogeneity. Using data with three-layered gold nanoparticles loaded with cisplatin, nanotherapy is simulated with different levels of tissue heterogeneity, and the treatment response is measured in terms of tumor regression. The results show that tumor vascular density non-trivially influences the nanoparticle uptake and washout, and the associated tissue response. The drug ...


Longitudinal Tracking Of Physiological State With Electromyographic Signals., Robert Warren Stallard May 2018

Longitudinal Tracking Of Physiological State With Electromyographic Signals., Robert Warren Stallard

Electronic Theses and Dissertations

Electrophysiological measurements have been used in recent history to classify instantaneous physiological configurations, e.g., hand gestures. This work investigates the feasibility of working with changes in physiological configurations over time (i.e., longitudinally) using a variety of algorithms from the machine learning domain. We demonstrate a high degree of classification accuracy for a binary classification problem derived from electromyography measurements before and after a 35-day bedrest. The problem difficulty is increased with a more dynamic experiment testing for changes in astronaut sensorimotor performance by taking electromyography and force plate measurements before, during, and after a jump from a small ...


Anatomy, Implant Selection And Placement Influence Spine Mechanics Associated With Total Disc Replacement, Justin F.M. Hollenbeck Jan 2016

Anatomy, Implant Selection And Placement Influence Spine Mechanics Associated With Total Disc Replacement, Justin F.M. Hollenbeck

Electronic Theses and Dissertations

Through aging and injury, the intervertebral disc of the lumbar spine can undergo degeneration, leading to collapse of the vertebrae and low back pain, a symptom that affects half the adult population in any given year. In an effort to reduce low back pain, total disc replacement treatment removes the degenerated disc, restores natural height and lordosis of the segment, and preserves motion at the joint. Patient anatomy, implant selection, and implant placement play significant roles in a patient's outcomes after total disc replacement surgery. Thus, the objective of the work presented in this thesis was to develop a ...


Study Of Immobilizing Cadmium Selenide Quantum Dots In Selected Polymers For Application In Peroxyoxalate Chemiluminescence Flow Injection Analysis, Christopher S. Moore May 2013

Study Of Immobilizing Cadmium Selenide Quantum Dots In Selected Polymers For Application In Peroxyoxalate Chemiluminescence Flow Injection Analysis, Christopher S. Moore

Electronic Theses and Dissertations

Two batches of CdSe QDs with different sizes were synthesized for immobilizing in polyisoprene (PI), polymethylmethacrylate (PMMA), and low-density polyethylene (LDPE). The combinations of QDs and polymer substrates were evaluated for their analytical fit-for-use in applicable immunoassays. Hydrogen peroxide standards were injected into the flow injection analyzer (FIA) constructed to simulate enzyme-generated hydrogen peroxide reacting with bis-(2,4,6-trichlorophenyl) oxalate.

Linear correlations between hydrogen peroxide and chemilumenscent intensities yielded regression values greater than 0.9750 for hydrogen peroxide concentrations between 1.0 x 10-4 M and 1.0 x 10-1 M. The developed technique’s LOD was ...