New Tools For Monitoring Gamma Camera Uniformity, Brad K. Lofton Dec 2010

New Tools For Monitoring Gamma Camera Uniformity, Brad K. Lofton

Dissertations & Theses (Open Access)

Detector uniformity is a fundamental performance characteristic of all modern gamma camera systems, and ensuring a stable, uniform detector response is critical for maintaining clinical images that are free of artifact. For these reasons, the assessment of detector uniformity is one of the most common activities associated with a successful clinical quality assurance program in gamma camera imaging. The evaluation of this parameter, however, is often unclear because it is highly dependent upon acquisition conditions, reviewer expertise, and the application of somewhat arbitrary limits that do not characterize the spatial location of the non-uniformities. Furthermore, as the goal of any …


Assessment Of Morphology And Hemodynamics In Normal And Remodeled Microvasculature With Parameter Sensitivity Analysis, Shilpi Ghosh Dec 2010

Assessment Of Morphology And Hemodynamics In Normal And Remodeled Microvasculature With Parameter Sensitivity Analysis, Shilpi Ghosh

Master's Theses

The goal of this study was to compare the morphological and hemodynamic characteristics of normal and remodeled vascular networks in the mouse gracilis muscle. To this end, previously developed models to assess flows and vascular branching were used to assess the normal and remodeled microcirculatory networks. The analysis revealed that the average individual vessel flow rates for vessels of similar caliber and total volumetric flow rates in the networks do not change for vessels of the same caliber after remodeling. Connectivity changes and average diameters primarily change in the larger arterioles after remodeling. A few correlations could be made between …


Fracture Of Bone Using Microindentation, Séverine Vennin Aug 2010

Fracture Of Bone Using Microindentation, Séverine Vennin

Department of Engineering Mechanics: Dissertations, Theses, and Student Research

Osteoporosis is a current disease which is especially of concern to post-menopausal women. It is characterized by a decrease of bone density and an increase in the risk of fracture. Interest in the fracture mechanisms with respect to the underlying biological structure of the bone is of great interest to researchers in this field. In this thesis, a new method based on microindentation on rat femurs was developed to determine the relation between the viscoelastic and the fracture properties of bone. The main goal is to measure the viscoelastic properties by using a dynamic mechanical analysis indentation method and then …


Modeling Of Loose Contamination Scenarios To Predict The Amount Of Contamination Removed, Duriem Calderin Morales Jul 2010

Modeling Of Loose Contamination Scenarios To Predict The Amount Of Contamination Removed, Duriem Calderin Morales

FIU Electronic Theses and Dissertations

The objective of this research is to evaluate the influence of the factors identified by the Johnson, Kendall and Robert’s theory that affect the strength of the detachment force necessary to remove a particle of contaminant from a surface, and the roughness of the surface in which the contaminant is present, on predicting the efficiency of removal of loose contamination. Two methods were used to reach this objective: the first method consisted of quantifying the contamination by weight and the second method of quantifying the contamination by counting alpha and gamma particles. As a result, it was determined that for …


The Gel Documentation System: A Cornerstone To The Implementation Of The Introduction To Biotechnology And Introduction To Bioinformatics Cross-Disciplinary Course Series, Marcy Kelly, Gregory Lampard, Constance Knapp Jun 2010

The Gel Documentation System: A Cornerstone To The Implementation Of The Introduction To Biotechnology And Introduction To Bioinformatics Cross-Disciplinary Course Series, Marcy Kelly, Gregory Lampard, Constance Knapp

Cornerstone 3 Reports : Interdisciplinary Informatics

No abstract provided.


Waste To Work Using Eccrine Sweat Battery Modules To Enhance Pedestrian Safety, Lauren J. Vesty May 2010

Waste To Work Using Eccrine Sweat Battery Modules To Enhance Pedestrian Safety, Lauren J. Vesty

Honors Capstone Projects - All

There is a need for increased pedestrian visibility. Improved athletic clothing with built in visibility features would enhance a roadside athlete’s safety. This experiment aims to create such an athletic shirt, while incorporating wearable biotechnology. A sweat battery that produced a voltage of 0.49 V and a current of 5.16 mA was created to power the visibility aspects of the shirt. The battery uses an aluminum anode, a carbon cathode, a sponge block as the container and semi-permeable membrane, and the body’s eccrine sweat as the electrolyte solution. The battery cells were arranged into blocks to produce an optimal current …


An Investigative Study Into The Relationship Of Bone Morphogenetic Protein Antagonist Expression And Osteocyte Density By Region And Quadrant, Scott C. Mosher Apr 2010

An Investigative Study Into The Relationship Of Bone Morphogenetic Protein Antagonist Expression And Osteocyte Density By Region And Quadrant, Scott C. Mosher

Master's Theses

The role of cytokines and cell behavior and viability with respect to bone remodeling and bone behavior is an exciting area of orthopedic research. The purpose of this study was to investigate the relationships between BMP antagonist expression and osteocyte density, lacunar densities and osteocyte viability in cortical bone. Samples of unloaded tibial bone obtained from six C57Bl/6 mice were immunohistochemically stained for gremlin and noggin expression and also underwent methyl green staining to determine osteocyte presence. Bone sections were divided into four quadrants (cranial, caudal, medial and lateral) and three regions (proximal, mid shaft and distal), followed by analysis …


Finite Element Analysis And Modeling Of A .38 Lead Round Nose Ballistic Gelatin Test, Danielle Datoc Apr 2010

Finite Element Analysis And Modeling Of A .38 Lead Round Nose Ballistic Gelatin Test, Danielle Datoc

Master's Theses

Firearms are present in two-thirds of United States households. As of 2003, roughly 500,000 projectile wounds occur annually in the United States. This costs an estimated 2.3 billion dollars of medical spending. The best treatment of gunshot wounds relies heavily on experience, but even with experience the unpredictable nature of ballistics can make treatment difficult.

Wound ballistics studies the injury pattern of a particular bullet. Ballistic gelatin tests are used to analyze this pattern. A block of 10 or 20% ballistic gelatin is set and a bullet is fired through the block. Key characteristics of the wound profile seen in …


Development Of A Novel Noise Delivery System For Jp-8 Ototoxicity Studies, John E. Stubbs Mar 2010

Development Of A Novel Noise Delivery System For Jp-8 Ototoxicity Studies, John E. Stubbs

Theses and Dissertations

Numerous chemicals with ototoxic properties may cause hearing loss directly, potentiate noise-induced hearing loss, or produce additive effects. Of interest to the US Air Force are studies showing ototoxic effects of JP-8 jet fuel and its hydrocarbon constituents. The Naval Health Research Center (NHRC) at Wright-Patterson AFB, Ohio, in conjunction with the USAF, is studying the ototoxic effects of JP-8 in rats. The study requires a white noise source that is one octave band wide, centered at 8 kHz frequency, delivered from outside of exposure chambers. Sound pressure levels must be within ± 2 dB at all exposure points within …


An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore Feb 2010

An Investigation Of Humeral Stress Fractures In Racing Thoroughbreds Using A 3d Finite Element Model In Conjunction With A Bone Remodeling Algorithm, Ryan James Moore

Master's Theses

The humerus of a racing horse Thoroughbred is highly susceptible to stress fractures at a characteristic location as a result of cyclic loading. The propensity of a Thoroughbred to exhibit humeral fracture has made equines useful models in the epidemiology of stress fractures. In this study, a racing Thoroughbred humerus was simulated during training using a 3D finite element model in conjunction with a bone remodeling algorithm. Nine muscle forces and two contact forces were applied to the 3-dimensional finite element model, which contains four separate load cases representing fore-stance, mid-stance, aft-stance, and standing. Four different training programs were incorporated …