Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 30 of 45

Full-Text Articles in Biomedical Engineering and Bioengineering

Numerical Investigation Of Subglottal Stenosis Effects On Human Voice Production, Dariush Bodaghi Dec 2023

Numerical Investigation Of Subglottal Stenosis Effects On Human Voice Production, Dariush Bodaghi

Electronic Theses and Dissertations

This dissertation aimed to advance knowledge of how subglottal stenosis impacts voice production physiology. An in-house fluid-structure-acoustic interaction approach based on the hydrodynamic/acoustic splitting technique was employed. This technique was rigorously verified for simulating phonation by matching the acoustic behavior to a compressible flow solver for phonation-relevant geometries. Simulations of an idealized 2D vocal tract model demonstrated the effects of supraglottal acoustic resonance on vocal fold kinematics and glottal flow waveform. Results showed that the acoustic coupling between higher harmonics and formats generated pressure oscillations, modifying vocal fold dynamics and glottal flow rate.

A major novelty was the incorporation and …


Kinematic Analysis Of Gait And Deep Knee Flexion For Pre- And Post-Operative Total Knee Arthroplasty, Samantha Collins Nov 2023

Kinematic Analysis Of Gait And Deep Knee Flexion For Pre- And Post-Operative Total Knee Arthroplasty, Samantha Collins

Electronic Theses and Dissertations

Osteoarthritis (OA) is a form of arthritis that develops in the joint due to overuse and aging causing pain, discomfort, and disability. Total Knee Arthroplasty (TKA) is a surgical procedure performed when OA symptoms are severe with an estimated 600,000 patients in the United States currently receiving TKA. Studies have reported dissatisfaction of the knee for 14-39% of patients. This study collected knee kinematics before and after surgery using stereo radiography for precise measurement of gait and deep knee flexion activities. Results showed healthy knee kinematics were not restored and no significant changes could be seen from OA kinematics in …


Computational Methodology For Generating Patient-Specific Soft Tissue Representations, Ahilan Anantha Krishnan Nov 2023

Computational Methodology For Generating Patient-Specific Soft Tissue Representations, Ahilan Anantha Krishnan

Electronic Theses and Dissertations

This dissertation focused on modeling specimen-specific soft tissue structures in the context of joint replacement surgery. The research addressed four key aspects. The first study involved developing a workflow for creating finite element models of the hip capsule to replicate its torque-rotational response. Experimental data from ten cadaveric hips were used to calibrate the models, resulting in improved accuracy and relevance for surgical planning and implant design. The second study tackled the challenge of expediting the calibration of mechanical properties of the hip capsule to match patient-specific laxities. A statistical shape function model was proposed to generate patient-specific finite element …


Digital Twins Of The Living Knee: From Measurements To Model, Thor Erik Andreassen Nov 2023

Digital Twins Of The Living Knee: From Measurements To Model, Thor Erik Andreassen

Electronic Theses and Dissertations

Modern medicine has dramatically improved the lives of many. In orthopaedics, robotic surgery has given clinicians superior accuracy when performing interventions over conventional methods. Nevertheless, while these and many other methods are available to ensure treatments are performed successfully, far fewer methods exist to predict the proper treatment option for a given person. Clinicians are forced to categorize individuals, choosing the best treatment on “average.” However, many individuals differ significantly from the “average” person, for which many of these treatments are designed. Going forward, a method of testing, evaluating, and predicting different treatment options' short- and long-term effects on an …


Designing And Modeling A Fail-Safe Mechanism To Be Used In Attachment Of A Transcutaneous Femoral Implant To A Prosthetic Device, Emma Sperry Aug 2023

Designing And Modeling A Fail-Safe Mechanism To Be Used In Attachment Of A Transcutaneous Femoral Implant To A Prosthetic Device, Emma Sperry

Electronic Theses and Dissertations

Amputations are quite common and even modern prosthetic devices are plagued by problems. There are approximately 2 million people living with limb loss in the U.S. and on average 185,000 amputations occur yearly. Common attachment mechanisms for external prosthetic components to a residual limb, that is, sockets, pose numerous challenges. Issues include skin irritation, discomfort, socket fit issues, and immobility. Issues include skin irritation, discomfort, socket fit issues, and immobility. Transcutaneous implants have great potential as a connection method for external prosthetic components to a residual limb but because the implants are typically solid, they correlate to extremely high infection …


Development And Application Of A Microfluidic Platform For Quantifying Intra-Tumoral Compressive Stress., Zachary P. Fowler Aug 2023

Development And Application Of A Microfluidic Platform For Quantifying Intra-Tumoral Compressive Stress., Zachary P. Fowler

Electronic Theses and Dissertations

Cancer progression is linked to the emergence of aberrant mechanical signaling in the tumor microenvironment. Modulation of extrinsic signals, such as ECM stiffness and composition, have been thoroughly explored. However, the development of solid stresses within the tumor remains poorly understood. To address this, we have developed a microfluidic platform that generates deformable alginate microbeads that allow for the quantification of compressive stresses generated within a growing glioblastoma (GBM) tumorsphere. PDMS microfluidic devices were fabricated via SU-8 mold with channels ranging from 10µm-40µm in diameter. Fluorescently labeled sodium alginate underwent a cross-linking reaction within the device to generate monodisperse beads …


Finite Element Modeling Of Patient-Specific Total Shoulder Arthroplasty, Ignacio Rivero Crespo Aug 2023

Finite Element Modeling Of Patient-Specific Total Shoulder Arthroplasty, Ignacio Rivero Crespo

Electronic Theses and Dissertations

Total Shoulder Arthroplasty (TSA) is a surgical procedure designed to improve joint functionality by replacing the articulation between the humeral head and the glenoid fossa. Anatomic Total Shoulder Arthroplasty (aTSA) and Reverse Total Shoulder Arthroplasty (rTSA) are two types of replacement surgery to relieve pain and restore function of the shoulder. The overall goal of this study was to evaluate the effects of variation of certain patient and implant alignment parameters that may influence long-term outcomes of these surgical procedures, including kinematics, joint loads and contact mechanics. Computational models of six TSA subjects, three aTSA and three rTSA, were created …


Patient Movement Monitoring Based On Imu And Deep Learning, Mohsen Sharifi Renani Jun 2023

Patient Movement Monitoring Based On Imu And Deep Learning, Mohsen Sharifi Renani

Electronic Theses and Dissertations

Osteoarthritis (OA) is the leading cause of disability among the aging population in the United States and is frequently treated by replacing deteriorated joints with metal and plastic components. Developing better quantitative measures of movement quality to track patients longitudinally in their own homes would enable personalized treatment plans and hasten the advancement of promising new interventions. Wearable sensors and machine learning used to quantify patient movement could revolutionize the diagnosis and treatment of movement disorders. The purpose of this dissertation was to overcome technical challenges associated with the use of wearable sensors, specifically Inertial Measurement Units (IMUs), as a …


Effect Of Dorsal Quadrant Or Ventral Quadrant Spinal Cord Injury On Gait Features During Locomotion., Anya Nicole Trell Aug 2022

Effect Of Dorsal Quadrant Or Ventral Quadrant Spinal Cord Injury On Gait Features During Locomotion., Anya Nicole Trell

Electronic Theses and Dissertations

In the Unites States, approximately 1.5 million people currently have a spinal cord injury and suffer permanent sensory and motor loss due to the disruption of the spinal cord. Due to the significant morbidity, it is vital to understand the functional impact of disrupting neural descending pathways that modulate spinal neurons involved in intermuscular coordination critical for gait behaviors. Tasks that are more difficult require additional input from these neural pathways; therefore, fourteen feline subjects were familiarized with level overground locomotion and stair descent gait tasks. After collection of baseline kinematic data, the subjects received either a dorsal or ventral …


Aerodynamics And Turbulent Wake-Flow Characteristics Of Owls During Flapping Flight, Krishnamoorthy Krishnan May 2022

Aerodynamics And Turbulent Wake-Flow Characteristics Of Owls During Flapping Flight, Krishnamoorthy Krishnan

Electronic Theses and Dissertations

Owls exhibit unique flight capabilities in the low Reynolds number flow regime which is prone to complex viscous flow phenomena. They possess unique feather features and flexible wing structures which are postulated to help them fly nearly silently and stably at low speeds in a complex flow setting. Understanding the aerodynamics of owls could pave the way to enhance the future designs of small flying vehicles. Though it has been a focus of research over multiple decades, no conclusive agreement has been attained on the aerodynamic mechanisms associated with owl flight. Particularly, the aerodynamics of flapping owl flight is severely …


Release Kinetics Of Metronidazole From 3d Printed Silicone Scaffolds., Sydney E. Herold May 2022

Release Kinetics Of Metronidazole From 3d Printed Silicone Scaffolds., Sydney E. Herold

Electronic Theses and Dissertations

Sustained local administration of active agents has been proposed to cure bacterial vaginosis in the female reproductive tract and restore the resident bacterial fauna. Bioprinting has shown promise for the development of systems for local agent delivery. In contrast to oral ingestion, agent release kinetics can be fine-tuned by bioprinting specialized scaffold designs tailored for particular treatments while enhancing dosage effectiveness via localized sustained release. It has been challenging to establish scaffold properties for sustained release as a function of fabrication parameters. Towards this goal, we evaluate 3D printed scaffold formulation and feasibility to sustain release of metronidazole, a representative …


Improving Quantification Of Mitral Regurgitation Through Computational Fluid Dynamics And Ex Vivo Testing, Alexandra Flowers Jan 2022

Improving Quantification Of Mitral Regurgitation Through Computational Fluid Dynamics And Ex Vivo Testing, Alexandra Flowers

Electronic Theses and Dissertations

Mitral regurgitation (MR) is a prominent cardiac disease affecting more than two million people in the United States alone. In order for patients to receive proper therapy, regurgitant volume must first be quantified. As there are an array of methods to do so, the proximal isovelocity surface area (PISA) method continues to be the most accurate and clinically used method. However, there are some difficulties obtaining the necessary measurements need for this when performing transthoracic echocardiography. This study aims to evaluate and present techniques that may be used to more accurately quantify regurgitation through ex vivo testing and computational fluid …


Pulmonary Valve Replacement, Mina Shafiei Jan 2022

Pulmonary Valve Replacement, Mina Shafiei

Electronic Theses and Dissertations

Currently, transcatheter pulmonary valve replacement (TPVR) is a well-established alternative for surgical pulmonary valve replacement (SPVR) to treat pulmonary valve disorders in patients with prior congenital heart surgery. Edwards Sapien 3 valve is a bioprosthesis originally designed for the aortic position but has been used off-label in native right ventricular outflow tract (RVOT). It is currently under clinical trial to get food and drug administration (FDA) approval.

This study is a comparison of the performance of Sapien 3 with surgical bioprosthetics. The in vitro tests result showed Sapien 3 experiences less degree of opening and effective orifice area in pulmonic …


Structural And Hemodynamic Analysis Of Transcatheter Aortic Valves, Dong Qiu Jan 2022

Structural And Hemodynamic Analysis Of Transcatheter Aortic Valves, Dong Qiu

Electronic Theses and Dissertations

The transcatheter aortic valve replacement (TAVR) procedure has become a well-established procedure for high, intermediate-risk, and low-risk patients. However, there is limited clinical data on the TAV's long-term durability, unlike SAV devices. Computational simulations can be an alternative way to evaluate the TAV devices. This dissertation aims to conduct structural and hemodynamic analyses on the TAV devices under different conditions using computational simulation approaches.

Initially, the impact of the bicuspid aortic valve on the TAV devices was evaluated. The result indicated that the CoreValve-like supra-annular self-expandable device was likely to have increased stress and strain on the leaflet when it …


An Investigation Into The Plate Fixation For Periprosthetic Femoral Fractures, Xiang Chen Jan 2022

An Investigation Into The Plate Fixation For Periprosthetic Femoral Fractures, Xiang Chen

Electronic Theses and Dissertations

Periprosthetic femoral fractures are the third most reason for reoperation after the total hip arthroplasty with an incident rate of approximately 6%. The Vancouver type B periprosthetic femoral fractures account for over 70% of all cases, while the sub-type B1 fracture (when the total hip stem is stable) has remained a clinical challenge due to incidences of severe complications after the standard plate-screw fixation. To seek biomechanically sound fixations for the Vancouver type B1 fracture, this dissertation developed a combined modeling and testing framework to investigate the efficacy of fixation for a Vancouver type B1 fracture using different construct lengths …


Revision Total Hip Femoral Stem Micromotion And Statistical Shape Modeling Of The Knee, William Fugit Jan 2022

Revision Total Hip Femoral Stem Micromotion And Statistical Shape Modeling Of The Knee, William Fugit

Electronic Theses and Dissertations

The first purpose of this thesis was to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of micromotion at the bone-implant interface was larger for activities of daily living, with ranges of 200μm more than the largest simple loading conditions. The second purpose of this thesis was to compare measurements of accuracy in a statistical shape model between individual bone and joint-level models, specifically for the knee. Using computational …


Development Of A Novel Haptic Feedback System For Gait Training Applications, Mohsen Alizadeh Noghani Aug 2021

Development Of A Novel Haptic Feedback System For Gait Training Applications, Mohsen Alizadeh Noghani

Electronic Theses and Dissertations

Until recently, study and correction of motor or gait functions required costly sensors and measurement setups (e.g., optical motion capture systems) which were only available in laboratories or clinical environments. However, due to (1) the growing availability and affordability of inertial measurement units (IMUs) with high accuracy, and (2) progress in wireless, high bandwidth, and energy-efficient networking technologies such as Bluetooth Low Energy (BLE), it is now possible to measure and provide feedback in real-time for biomechanical parameters outside of those specialized settings. To enable gait training without an expert who can provide verbal feedback, augmented feedback, which is divided …


Bilateral Ground Reaction Force Jumping Asymmetry And Performance, Keith Painter Aug 2021

Bilateral Ground Reaction Force Jumping Asymmetry And Performance, Keith Painter

Electronic Theses and Dissertations

The prevalence of asymmetry in performance research has increased in recent years with mixed results. Much of the performance research has focused on unilateral jumping activities attempting to show relationships to other performance variables. However, bilateral ground reaction forces (bGRF) from jumps are more frequently assessed in athlete monitoring programs and the asymmetry from those jumps could be a simple addition to data already being collected. Research into bGRF asymmetries is lacking and no studies have addressed longitudinal changes. Additionally, research into the relationship of asymmetries to performance have infrequently used athletes. For these reasons, this dissertation will focus on …


An Accuracy And Precision Analysis Of The Velys™ Robotic Assisted Solution For Total Knee Arthroplasty, Gary Doan Jan 2021

An Accuracy And Precision Analysis Of The Velys™ Robotic Assisted Solution For Total Knee Arthroplasty, Gary Doan

Electronic Theses and Dissertations

Total knee arthroplasty (TKA) is a procedure where the arthritic surfaces of the knee is removed and replaced with a combination of metal and polymer implants that recreates the joint line to restore function and quality of life. Implant alignment is important in the success of a TKA. Modern day conventional instrumentation can be cumbersome in the operating room and can be inaccurate when resecting bone and aligning implants. Patients with large errors in resections and implant orientation are more prone to experience mechanical failures with their TKA. Mechanical failures in primary TKA require revision surgeries which can lead to …


Accurate Measurement Of Healthy Joint Kinematics To Inform Diagnosis And Treatment, Vasiliki Kefala Jan 2021

Accurate Measurement Of Healthy Joint Kinematics To Inform Diagnosis And Treatment, Vasiliki Kefala

Electronic Theses and Dissertations

The description of human motion has a primary importance in different scientific areas such as medicine, sports, physical therapy. Kinematics specifically studies pure motion without reference to the causes of motion such as forces. Understanding the kinematics of human movement is of critical importance in medicine and biology. Motion measure­ment can be used in order to to evaluate functional performance of limbs under normal and abnormal conditions. Kinematic knowledge is also important for diagnosis and surgi­cal treatment of joint disease and the design of implants to rehabilitate function. Accurate joint kinematics is essential to protect articular functionality. An alteration may …


Dislocation Mechanics Of Total Hip Arthroplasty: A Combined Experimental And Computational Analysis, Michael Scinto Jan 2021

Dislocation Mechanics Of Total Hip Arthroplasty: A Combined Experimental And Computational Analysis, Michael Scinto

Electronic Theses and Dissertations

While total hip arthroplasty is considered a successful procedure, dislocation remains a serious complication as recurrent dislocations may require additional surgeries. Knowledge on dislocation events as they occur in vivo are limited, therefore researchers rely on experimental and computational methods. A custom MATLAB script and an experimental procedure utilizing a six-degree of freedom actuator were developed to further understand how various surgical considerations affect dislocation mechanics in total hip arthroplasty. Computationally, it was determined that impingement free range of motion is limited during internal rotation in flexion and during external rotation in extension. Experimentally, our results suggest that the posterior …


Multiphysics Computational Model Of Fluid Flow And Mass Transport In Aneurysm, Tanja Cupac Aug 2020

Multiphysics Computational Model Of Fluid Flow And Mass Transport In Aneurysm, Tanja Cupac

Electronic Theses and Dissertations

The abdominal aortic aneurysm is progressive, asymptomatic, and can eventually lead to rupture which is a catastrophic event leading to massive internal bleeding and possibly death. AAA cases have been characterized by the development of an intraluminal thrombus (ILT). The ILT correlates with the progression of hypoxia in the arterial wall. The extent that ILT presence reduces oxygen flux to the wall has not been quantified and there is rather a poor understanding of key parameters that can affect thrombus-mediated oxygen transport in AAA. The purpose of this study is to address this gap and to assess the effects of …


Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi Jan 2020

Transcatheter Mitral Valve Replacement: Structural And Hemodynamic Analysis, Saba Ravaghi

Electronic Theses and Dissertations

Transcatheter mitral valve replacement (TMVR) is being developed to become a substitute therapy for surgery in prohibitive or high surgical risk patients to treat severe mitral regurgitation. A limited number of TMVR systems are under clinical evaluation. However, transcatheter mitral valve (TMV) long-term durability and hemodynamic performance is not known. TMV durability and hemodynamics must match with that of surgical bioprostheses for potential commercialization of TMVR. Experimental and computational approaches were used to find the leaflets’ three-dimensional anisotropic mechanical properties in a transcatheter Edwards SAPIEN 3 valve and a surgical Carpentier-Edwards PERIMOUNT Magna mitral valve and finite element (FE) simulations …


In Vivo Data Capture Using Hssr For Calibration Of Computational Models, Thor Erik Andreassen Jan 2020

In Vivo Data Capture Using Hssr For Calibration Of Computational Models, Thor Erik Andreassen

Electronic Theses and Dissertations

Computational modeling is a vital tool for understanding and evaluating healthy and unhealthy function of the musculoskeletal aspects of the human body. However, the accuracy of the musculoskeletal models depends significantly on the accuracy of the input data used to calibrate various behavioral parameters of the model. To date, most computational models have been built using generic in vitro data, mostly because of a lack of accurate and meaningful datasets from in vivo testing. The next major step in computational modeling is to create subject-specific computational models using calibration data taken from in vivo testing. The overall goal was to …


Development Of A Clinical Marker-Less Motion Capture System For Patient Monitoring, Abigail Eustace Jan 2020

Development Of A Clinical Marker-Less Motion Capture System For Patient Monitoring, Abigail Eustace

Electronic Theses and Dissertations

The ability to understand human movement is beneficial for deciding surgical procedures, tracking disease progression over time and helping with patient rehabilitation. The current gold-standard for collecting human movement is the use of 3-dimensional marker-based systems. Several studies have presented the many limitations to the current gold-standard that reduces the number of people who are able to benefit from a gait analysis. Those limitations in the current gold-standard include the requirements of large laboratory space, costly equipment, long instrumentation and collection time, and the potential for motion artifact from markers being placed on the skin. The purpose of this study …


The Effects And Analysis Of Implant Type And Surgical Approach In Total Hip Arthroplasty Dislocation Resistance, Brittany Marshall Jan 2020

The Effects And Analysis Of Implant Type And Surgical Approach In Total Hip Arthroplasty Dislocation Resistance, Brittany Marshall

Electronic Theses and Dissertations

Total hip arthroplasty (THA) is one of the most successful orthopaedic surgeries performed, in which the hip joint is reconstructed to decrease pain and to improve the functionality to the joint. Although these surgeries are very successful, there still remain areas for improvement, such as failures due to instability and dislocation of the implanted joint. The purpose of this thesis is to investigate the effect of surgical entrance approach on dislocation, the effect of implant type, and the effect of capsule repair and closure. The need to quantify the resistance to dislocation is important in understanding the effect that each …


A Longitudinal Examination Of Biomechanical Balance And Quantitative Multidomain Assessments During Recovery Following Sport-Related Concussion, Moira Kate Pyrhoda Jan 2020

A Longitudinal Examination Of Biomechanical Balance And Quantitative Multidomain Assessments During Recovery Following Sport-Related Concussion, Moira Kate Pyrhoda

Electronic Theses and Dissertations

Sport-related concussion is an inherent risk to athlete health in contact and collision sports. Both short- and long-term risks are associated with the injury. Short-term, athletes may develop post-concussion syndrome (PCS), the persistence of cognitive, physical, and emotional symptoms for weeks or months after injury. Athletes who return to play (RTP) prematurely are at increased risk for lower extremity injury and repeated concussion injuries. Long-term, history of multiple concussions have been linked to neurodegenerative diseases. Due to these risks, concussion assessments must be sensitive to the injury and useful in the diagnosis, recovery, and RTP phases of the injury.

Sideline …


Energy Expenditure And Stability During Self-Paced Walking On Different Slopes, Alanna Raffaelli May 2019

Energy Expenditure And Stability During Self-Paced Walking On Different Slopes, Alanna Raffaelli

Electronic Theses and Dissertations

Metabolic power and cost of transport (COT) are common quantifiers for effort when performing tasks including walking and running. Most studies focus on using a range of normal walking speeds over level ground or varied slopes. However, these studies use fixed-speed conditions. Fatigue, stability, metabolic expenditure, heart rate, and many other factors contribute to normal walking speed varying over time. This study aimed to show that allowing a subject to walk with a self-paced speed should correlate to a minimum COT at a given slope. This study also aimed to determine if a preferred slope exists based on minimizing metabolic …


Conceptualization And Fabrication Of A Bioinspired Mobile Robot Actuated By Shape Memory Alloy Springs, Lietsel Richardson May 2019

Conceptualization And Fabrication Of A Bioinspired Mobile Robot Actuated By Shape Memory Alloy Springs, Lietsel Richardson

Electronic Theses and Dissertations

This work is an experimental study and fabrication of design concepts to validate the feasibility of smart materials and their applications in bio-inspired robotics. Shape-Memory Alloy (SMA) springs are selected as the smart material actuators of interest to achieve locomotion in the proposed mobile robot. Based on a previous design of the robot, this work focuses on both implementing a new locomotion concept and reducing size and weight of the previous design, both using SMA based actuators. Objectives are met in consideration of the conceptual mechanics of circular robot locomotion. The first prototype is a variation of the original design. …


Fluctuations In Walking Speeds And Spatiotemporal Gait Parameters When Walking On A Self-Paced Treadmill At Level, Incline, And Decline Slopes, Cesar Castano May 2019

Fluctuations In Walking Speeds And Spatiotemporal Gait Parameters When Walking On A Self-Paced Treadmill At Level, Incline, And Decline Slopes, Cesar Castano

Electronic Theses and Dissertations

On a daily basis, humans walk over a variety of terrains. Studies have shown that spatiotemporal gait parameters, such as stride length, stride frequency, stride variability, etc., change when humans walk down a decline and up an incline compared to level ground. However, these studies have been limited to using fixed speed treadmills or analyzing a small number of strides when conducted over ground. Thus, there is a need to investigate the fluctuations in spatiotemporal gait parameters of humans walking at their self-selected speed, which requires recording hundreds of strides. Here we hypothesized that subjects will walk with a slower …