Full-Text Articles in Engineering

Energy Performance Certification: Misassessment Due To Assuming Default Heat Losses, Ciara Ahern, Brian Norton Dec 2019

Energy Performance Certification: Misassessment Due To Assuming Default Heat Losses, Ciara Ahern, Brian Norton

Articles

Energy Performance Certificates (EPCs) are issued when dwellings are constructed, sold or leased in the EU. Where the cost of obtaining the required data is prohibitive, EPC assessors use nationally applicable default-values. To ensure that dwellings are not assigned a wrongly-higher EPC rating, a standardised thermal bridging transmittance coefficient (Y-value) is typically adopted for all existing dwellings while worst-case overall heat loss coefficients (U-values) are used. Default U-values are applied to a specific building element type (roof, wall, floor etc.) based on building codes and regulations applicable at time of construction. Due to significant building fabric upgrades, default U-values are …


Experimental Investigation Of Flow Pulsation Waveforms In Rectangular Mesochannels For High Heat Flux Electronics Cooling, Jaakko Mcevoy, Sajad Alimohammadi, Tim Persoons Dec 2019

Experimental Investigation Of Flow Pulsation Waveforms In Rectangular Mesochannels For High Heat Flux Electronics Cooling, Jaakko Mcevoy, Sajad Alimohammadi, Tim Persoons

Articles

The ever rising heat fluxes encountered in electronic devices present a challenging thermal engineering problem. Not only is heat transfer enhancement a goal but more recently control of the enhancement is desired, especially in large scale data facilities where the heated outlet coolant fluid may be of use. Flow pulsation is one of the most common active heat transfer enhancement methods studied across all heat sink sizes. While the effects of pulsation have been shown to increase heat transfer under certain conditions there is still disagreement upon its merit for practical applications, with the majority of previous research has been …


A Generalisable Bottom-Up Methodology For Deriving A Residential Stock Model From Large Empirical Databases, Ciara Ahern, Brian Norton Dec 2019

A Generalisable Bottom-Up Methodology For Deriving A Residential Stock Model From Large Empirical Databases, Ciara Ahern, Brian Norton

Articles

Specifying representative reference buildings as a prerequisite for calculating cost-optimal energy performance requirements for buildings and building elements. Appropriate characterisation is prerequisite data for an overall national building energy consumption model to produce valid outcomes. Energy Performance Certificates (EPCs) are issued in the EU, for dwellings whenever they are constructed, sold or leased. Where acquiring data for an EPC would be prohibitively costly, nationally applicable default-values are employed for the building envelope thermal transmittance coefficients. Significant levels of retrofits led to the default-values used now being higher than is typical in reality, leading to characterisations of reference dwellings based on …


Thermal Energy Refurbishment Status Of The Irish Housing Stock, Ciara Ahern, Brian Norton Nov 2019

Thermal Energy Refurbishment Status Of The Irish Housing Stock, Ciara Ahern, Brian Norton

Articles

Energy Performance Certificates (EPCs) are issued for buildings constructed, sold or leased across the EU. Using a generalizable methodology this work exploits Ireland's EPC national dwelling stock database to determine the thermal refurbishment status of Ireland's housing stock. It is estimated in 2014 that; i) 58% of walls were insulated at a mean overall heat loss coefficient or U-value of 0.66 W/m2K, ii) 67% of roofs were insulated at a mean U-value 0.37 W/m2K, iii) 97% of windows were double-glazed, and iv) 53% of floors were insulated to a mean U-value of 0.59 W/m2K. …


Thermal Refurbishment Status Of The Irish Housing Stock, Ciara Ahern, Brian Norton Oct 2019

Thermal Refurbishment Status Of The Irish Housing Stock, Ciara Ahern, Brian Norton

Articles

Energy Performance Certificates (EPCs) are issued for buildings constructed, sold or leased across the EU. Using a generalizable methodology this work exploits Ireland’s EPC national dwelling stock database to determine the thermal refurbishment status of Ireland’s housing stock. It is estimated in 2014 that; i) 58% of walls were insulated at a mean overall heat loss coefficient or U-value of 0.66 W/m 2 K, ii) 67% of roofs were insulated at a mean U-value 0.37 W/m 2 K, iii) 97% of windows were double-glazed, and iv) 53% of floors were insulated to a mean U-value of 0.59 W/m 2 K. …


A Techno-Economic Analysis Of Current Cooling Techniques In Irish Data Centres, Lee Gibbons, Bryan Coyne, David Kennedy, Sajad Alimohammadi Sep 2019

A Techno-Economic Analysis Of Current Cooling Techniques In Irish Data Centres, Lee Gibbons, Bryan Coyne, David Kennedy, Sajad Alimohammadi

Articles

This research is part of a comprehensive study to determine reformative actions for cooling regimes within the Irish data centre market. To achieve this goal, preliminary Exergy, Entropy change and operational cost analyses are used. It is determined that there is no clear advantage for using one cooling method over another without knowing the data centres secondary function (e.g. district heating, energy generation). Air cooling technology is a good candidate for a highly reliable system due to the low exhaust temperatures of 30°C. Two-phase immersion is a possibility for economically viable data centres where operational costs are to be minimised, …


Microwave Self-Healing Technology As Airfield Porous Asphalt Friction Course Repair And Maintenance System, Amir Tabakovic, Declan O'Prey, Drew Mckenna, David Woodward Mar 2019

Microwave Self-Healing Technology As Airfield Porous Asphalt Friction Course Repair And Maintenance System, Amir Tabakovic, Declan O'Prey, Drew Mckenna, David Woodward

Articles

A problem increasingly faced by airport authorities is the maintenance of runways. Due to their large aircraft loadings associated with take-off and landing operations, runways experience surface deterioration. Poor quality runway surfaces cannot be tolerated in such an environment. Maintenance issues must be carried out to maximise safety and minimise the risk of aircraft damage. A recent development has been the introduction of self-healing technologies such as rejuvenator encapsulation, induction and microwave heating to address these issues. This paper summarises a laboratory investigation to determine the effectiveness of microwave self-healing for crack repair of Porous Friction Course (PFC) used for …


The Influence Of Asphalt Ageing On Induction Healing Effect On Porous Asphalt Concrete, Shi Xu, Xueyan Liu, Amir Tabakovic, Erik Schlangen Feb 2019

The Influence Of Asphalt Ageing On Induction Healing Effect On Porous Asphalt Concrete, Shi Xu, Xueyan Liu, Amir Tabakovic, Erik Schlangen

Articles

Induction healing is a proven technology which is able to improve the self‐healing capacity of asphalt concrete. Healing is achieved via electromagnetic current produced by passing induction machine, where steel asphalt constituents heat up which in turn soften the bitumen in the asphalt layer, allowing it to flow and close cracks, repairing the damage. This paper reports on the study which investigated the influence of ageing on the healing capacity of Porous Asphalt (PA) concrete. Porous Asphalt concrete mix was prepared first, then subjected to an accelerated (laboratory) ageing process using a ventilated oven. In order to further evaluate the …


A Novel Approach Towards Investigating The Performance Of Different Pvt Configurations Integrated On Test Cells: An Experimental Study, Vivek Tomar, Brian Norton, G. N. Tiwari Jan 2019

A Novel Approach Towards Investigating The Performance Of Different Pvt Configurations Integrated On Test Cells: An Experimental Study, Vivek Tomar, Brian Norton, G. N. Tiwari

Articles

This study elaborates the theoretical and experimental analysis for the effectiveness of different photovoltaic thermal (PVT) configurations along with their building implications. An experiment was performed on especially designed four identical prototype test cells emphasise the building integration photovoltaic thermal (BiPVT) systems. A comparative analysis of four different possible PVT configurations integrated on identical test cells namely; Case 1: Glass-to-glass PV with duct integrated on a test cell, Case 2: Glass-to -glass PV without duct integrated on a test cell, Case 3: Glass to tedlar PV with duct integrated on a test cell and Case 4: Glass to tedlar PV …


Calculation Methods Of Radon-222 Radiological Activity For Norm Plant With Ventilation, Pedro M. Dieguez-Elizondo, Paul G. O'Donohoe, Tomas Gil-Lopez, Juan Castejon-Navas, Miguel A. Gálvez-Huerta Jan 2019

Calculation Methods Of Radon-222 Radiological Activity For Norm Plant With Ventilation, Pedro M. Dieguez-Elizondo, Paul G. O'Donohoe, Tomas Gil-Lopez, Juan Castejon-Navas, Miguel A. Gálvez-Huerta

Articles

A procedure is proposed to determine the radiological activity of air present in the working area of a NORM (Naturally-Occurring Radioactive Materials) plant. This NORM plant is located in the United Arab Emirates and is dedicated to the recycling of material and equipment used in oil extraction facilities. Substantial quantities of NORM waste will be present inside the enclosed plant facilities and will exhale significant amounts of Radon-222 into the working environment. The continued inhalation of this gas and its progeny has been shown to cause lung cancer. In order to reduce the concentration level of the aforementioned gas to …