Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Publication
- Publication Type
Articles 1 - 11 of 11
Full-Text Articles in Engineering
Strengthening Of Corroded Steel Structures Using Cfrp – An Experimental Review, Ghada El-Mahdy Ph.D., P.Eng, Abdallah H. Yassin, Abdel El Rahman Khaled
Strengthening Of Corroded Steel Structures Using Cfrp – An Experimental Review, Ghada El-Mahdy Ph.D., P.Eng, Abdallah H. Yassin, Abdel El Rahman Khaled
Civil Engineering
Fibre reinforced polymers (FRP) have been widely used to strengthen reinforced concrete structures, however, nowadays their use to strengthen steel structures is under investigation. In particular, the need to strengthen corroded steel structures found in aggressive environments, such as marine environments, which have undergone a reduction in cross-sectional area and hence a reduction in their load-carrying capacity is in need of studying. The main problems that arise when using carbon fibre reinforced polymer (CFRP) sheets to strengthen steel structures is the weakness in the interfacial bond between the CFRP and the steel surface, the thinness of CFRP sheet, and the …
Application Of Bayesian Networks To Integrity Management Of Energy Pipelines, Wei Xiang
Application Of Bayesian Networks To Integrity Management Of Energy Pipelines, Wei Xiang
Electronic Thesis and Dissertation Repository
Metal-loss corrosion and third-party damage (TPD) are the leading threats to the integrity of buried oil and natural gas pipelines. This thesis employs Bayesian networks (BNs) and non-parametric Bayesian networks (NPBNs) to deal with four issues with regard to the reliability-based management program of corrosion and TPD. The first study integrates the quantification of measurement errors of the ILI tools, corrosion growth modeling and reliability analysis in a single dynamic Bayesian network (DBN) model, and employs the parameter learning technique to learn the parameters of the DBN model from the ILI-reported and filed-measured corrosion depths. The second study develops the …
Integrated Sensor Network For Monitoring Steel Corrosion In Concrete Structures, José Enrique Ramón-Zamora, José Manuel Gandia-Romero, Román Bataller, Ana Martínez-Ibernón, Isabel Gasch, Juan Soto
Integrated Sensor Network For Monitoring Steel Corrosion In Concrete Structures, José Enrique Ramón-Zamora, José Manuel Gandia-Romero, Román Bataller, Ana Martínez-Ibernón, Isabel Gasch, Juan Soto
International Conference on Durability of Concrete Structures
The developed Integrated Sensor Network (ISN) allows a non-destructive monitoring of the rebar condition at different parts of the structure. The corrosion sensor allows the accurate determination of the corrosion rate (µm/year). Moreover, additional sensors are integrated in order to detect relevant changes in the concrete electrochemical condition.
The ISN has been published as an international invention patent (reference number WO 2016/177929 A1). The system is based on an economic, simple, reliable and durable technology, which makes its implementation viable on new and repaired reinforced concrete structures (RCS). Therefore, it is also possible monitoring non-accessible parts such as deep foundations …
Micro-Mechanical Analysis Of Corrosion Products Formed During Long-Term Carbonation Induced Corrosion Of Steel, Marijana Serdar, Dubravka Bjegovic, Valérie L’Hostis, Stéphane Poyet, Damien Féron
Micro-Mechanical Analysis Of Corrosion Products Formed During Long-Term Carbonation Induced Corrosion Of Steel, Marijana Serdar, Dubravka Bjegovic, Valérie L’Hostis, Stéphane Poyet, Damien Féron
International Conference on Durability of Concrete Structures
During corrosion distinct types of corrosion products form, composed of different ratios of ferrous ions and oxide, hydroxides. Corrosion products have different physical and mechanical properties, mainly density, resistivity, volume and modulus of elasticity compared to iron. Knowing properties of corrosion products is indispensable for service life modelling of structures and can give valuable insight into the long-term corrosion propagation process. In this study micro-indentation method was used to evaluate mechanical properties of different layers formed during long-term carbonation induced corrosion of steel in concrete. Investigation was performed on three sets of reinforced concrete samples, that underwent corrosion during 50, …
Comparison Data Between Hybrid And Galvanic Anode Installation In The Arousa Island Bridge, José Antonio Becerra Mosquera, Diego Carro López, José Enrique Pardo Landrove, José Manuel Millán Pérez
Comparison Data Between Hybrid And Galvanic Anode Installation In The Arousa Island Bridge, José Antonio Becerra Mosquera, Diego Carro López, José Enrique Pardo Landrove, José Manuel Millán Pérez
International Conference on Durability of Concrete Structures
The Arousa Island Bridge, with its 1980 m is the only road access to the Arousa Island. Built in 1985, this single-cell box girder divided in 40 spans runs entirely on the sea. The deck is between 2 to 12 m above sea level, so after 25 years in a marine environment, the structure showed reinforcement corrosion, especially in piles and deck bottom. Attending to the corrosion damages, caused simply from a chloride attack, the local government decided to intervene with an ambitious repair project. This decision has been taken only after an exhaustive cost analysis to determine the feasibility …
Effect Of Time-Dependent Chloride Profile And Temperature Variation On Chloride Diffusion In Concrete, Feras Alsheet, A. Ghani Razaqpur
Effect Of Time-Dependent Chloride Profile And Temperature Variation On Chloride Diffusion In Concrete, Feras Alsheet, A. Ghani Razaqpur
International Conference on Durability of Concrete Structures
Reinforcement corrosion due to chlorides diffusion is one of the main problems in reinforced concrete structures exposed to certain environments. The diffusion rate is function of chloride surface concentration, concrete temperature, humidity, composition and microstructure. The intruded chlorides are partially chemically bound by the concrete and it is the unbound or free chloride which upon exceeding a defined threshold initiates corrosion. The time to corrosion initiation depends on the above variables; therefore, it is important to model their spatial and temporal variations in a manner that will yield a realistic estimate of the actual initiation period. In this study, the …
Durability Design Of Segmental Linings For Intended Service Life Of Tunnels, Mehdi Bakhshi, Verya Nasri
Durability Design Of Segmental Linings For Intended Service Life Of Tunnels, Mehdi Bakhshi, Verya Nasri
International Conference on Durability of Concrete Structures
In one-pass lining systems, the durability of tunnel structure is directly related to durability of concrete segments acting as both the initial support and the tunnel final lining. In this paper, most-frequent degradation mechanisms of concrete linings are discussed including chloride- and carbonation- induced corrosions, sulfate, acid and freeze-and-thaw attacks, and alkali-aggregate reactions. Mitigation method for each specific degradation mechanism is explained. A durability factor specific to railway and subway tunnel known as stray current corrosion is presented. Mitigation methods for this specific corrosion together with coupling effects with other conventional damage mechanisms are explained. Prescriptive approaches for durability design …
Sustainable Concrete With Seawater And Corrosion Resistant Reinforcement: Results Of Monitoring Of Corrosion Behaviour, Elena Redaelli, Maddalena Carsana, Federica Lollini, Matteo Gastaldi, Forood Torabian Isfahani
Sustainable Concrete With Seawater And Corrosion Resistant Reinforcement: Results Of Monitoring Of Corrosion Behaviour, Elena Redaelli, Maddalena Carsana, Federica Lollini, Matteo Gastaldi, Forood Torabian Isfahani
International Conference on Durability of Concrete Structures
The use of seawater for mixing concrete for reinforced concrete structures is prohibited, since it can promote steel corrosion. However, the use of seawater would contribute to decrease the environmental impact of concrete, in particular in those regions of the world where potable water is a precious resource. The project SEACON-INFRAVATION between University of Miami and Politecnico di Milano, with various industrial partners, aims at investigating the use of seawater for the construction of sustainable and durable reinforced concrete structures and infrastructures. Within the project, that included a vast campaign of laboratory tests, also two demo projects – one in …
Corrosion Durability Of A Nano-Particle Enriched Zinc-Rich Coating System For Highway Steel Bridges, Saiada Fuadi Fancy
Corrosion Durability Of A Nano-Particle Enriched Zinc-Rich Coating System For Highway Steel Bridges, Saiada Fuadi Fancy
FIU Electronic Theses and Dissertations
Corrosion is a major concern for the long-term durability and structural integrity of steel components of highway bridges when unprotected. The application of protective coatings has been widely used for corrosion mitigation of atmospherically exposed structural steel. At present, the zinc-rich primer (ZRP) based three-coat system is widely used in the United States. The metallic zinc pigment ideally would provide corrosion resistance by sacrificial as well as barrier protection. The life of these coating systems is at best only half of the bridge design life. Furthermore, premature degradation may occur if there are flaws in the system due to improper …
The Influence Of Incorporation Of Mn On The Pitting Corrosion Performance Of Crfeconi High Entropy Alloy At Different Temperatures, H. Torbati-Sarraf, Mitra Shabani, Paul D. Jablonski, Garrett J. Pataky, A. Poursaee
The Influence Of Incorporation Of Mn On The Pitting Corrosion Performance Of Crfeconi High Entropy Alloy At Different Temperatures, H. Torbati-Sarraf, Mitra Shabani, Paul D. Jablonski, Garrett J. Pataky, A. Poursaee
Publications
The electrochemical behavior and susceptibility to pitting corrosion of CrFeCoNi and CrMnFeCoNi high entropy alloys were studied in a 0.1 M NaCl solution at temperatures ranging from 25 to 75 °C. Electrochemical measurements revealed that CrMnFeCoNi is more susceptible to oxide film breakdown and localized corrosion compared to CrFeCoNi. Post corrosion microscopic observations showed severe pitting corrosion for CrMnFeCoNi in higher temperatures compared to CrFeCoNi. Based on in-depth XPS profile measurements on the remaining oxide films, this behavior was attributed to the depletion of Cr in the oxide film and detrimental presence of Mn in the matrix solid solution of …
Retrofitting Of Bridge Elements Subjected To Predominantly Axial Load Using Uhpc Shell, Mahsa Farzad
Retrofitting Of Bridge Elements Subjected To Predominantly Axial Load Using Uhpc Shell, Mahsa Farzad
FIU Electronic Theses and Dissertations
In the United States, ~30% of the ~600,000 highway bridges are categorized as structurally deficient or functionally obsolete. These bridges should be replaced or upgraded to sustain the transportation needs of the growing public and private sectors of the U.S. economy. It is not uncommon for structures to have advanced levels of corrosion-induced damage where major repair and maintenance works are required. However, the transportation infrastructure may undergo disruption during rehabilitation causing interruption to critical economic public, civil and commercial activities. This mandates the development of new techniques and materials for accelerated rehabilitation and resilience. To address this issue, a …