Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Electronic Thesis and Dissertation Repository

Kinematics

Medicine and Health Sciences

Publication Year

Articles 1 - 5 of 5

Full-Text Articles in Engineering

Biomechanical Analysis Of Ligament Modelling Techniques And Femoral Component Malrotation Following Tka, Liam A. Montgomery Dec 2021

Biomechanical Analysis Of Ligament Modelling Techniques And Femoral Component Malrotation Following Tka, Liam A. Montgomery

Electronic Thesis and Dissertation Repository

Previous studies have demonstrated that satisfaction and revision rates following total knee arthroplasty (TKA) are lower than those of comparable surgeries such as total hip replacements. A leading cause for these revisions is joint instability which may be due to improper ligament balancing or poorly aligned surgical implants. One of the methods used to investigate biomechanical forces and kinematics is computational modelling of the post-operative TKA knee.

A unique knee model was used to investigate the biomechanical and kinematic effects of ligament model complexity, as well as the effects of simulating ligament wrapping versus ignoring ligament wrapping. We then used …


4dct Analysis Of In-Vivo Carpal Kinematics During Fem, Manisha R. Mistry Sep 2021

4dct Analysis Of In-Vivo Carpal Kinematics During Fem, Manisha R. Mistry

Electronic Thesis and Dissertation Repository

A consensus, detailed understanding of carpal kinematics remains elusive. 4-dimensional CT (4DCT) is a validated modality capable of accurately studying in-vivokinematic motion. The objective of this work is to quantify normal, in-vivo kinematic motion of the carpus through a flexion-extension arc of motion using 4DCT. Ten healthy, un-injured volunteers underwent a 4DCT scanning protocol through a complete arc of flexion-extension motion. Kinematic changes in motion were quantified using helical axis motion data for each carpal bone. Helical axes were compared between bones and statistical analysis performed using repeated-measures ANOVA to identify difference in kinematic motion between bones (p<0.05). The carpus can be divided into four main kinematic blocks: the distal carpal block, the proximal carpal block and individual scaphoid and trapezial blocks. This work supports an additional segmentation of the trapezium from the distal carpal row, which suggests some modulation between the scaphoid and distal carpal row.


In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly Jan 2021

In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly

Electronic Thesis and Dissertation Repository

Optimal management of the hip capsule during arthroscopic surgery has not been established. The impact of incisions made to the capsule during minimally invasive procedures on joint biomechanics, and whether repair provides any benefit, continue to be debated. The effectiveness of capsular repair to restore native kinematics may be insufficient. Therefore, a better understanding of joint behavior during various capsule conditions is needed. A new robotic system was used to analyze the effect of progressive capsulotomy incision and repairs on the behavior of a normal hip within range of motion (ROM) limits with respect to the intact joint. Complete repairs …


Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon Apr 2016

Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon

Electronic Thesis and Dissertation Repository

The purpose of this collection of studies was to further develop the knowledge of shoulder motion in order to better understand joint function through direct measurement of 3D scapulohumeral joint kinematics using a technique of high accuracy. Markerless, bi-planar fluoroscopic radiostereometric analysis using a generic shoulder model was developed in this thesis, reducing the amount of radiation exposure to subjects. The studies compared kinematic data of the scapulohumeral joint in six degrees of freedom with a precise, in-vivo measuring technique. Data were collected on young and older healthy individuals, individuals with a torn supraspinatus and post-surgical intervention.

Although this generic …


The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari Sep 2014

The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari

Electronic Thesis and Dissertation Repository

Abstract:

The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries

Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.

Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …