Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Electronic Thesis and Dissertation Repository

Biomedical Engineering and Bioengineering

Elbow

Publication Year

Articles 1 - 4 of 4

Full-Text Articles in Engineering

The Effects Of A Porous Internal Lattice Design On The Articular Contact Mechanics Of Radial Head Hemiarthroplasty Implants, Jessica Benitah Mar 2022

The Effects Of A Porous Internal Lattice Design On The Articular Contact Mechanics Of Radial Head Hemiarthroplasty Implants, Jessica Benitah

Electronic Thesis and Dissertation Repository

Hemiarthroplasty, where one side of a joint is replaced, is a minimally invasive procedure. It allows for the preservation of native tissue, though a significant ramification is accelerated cartilage wear when articulating with high stiffness materials that do not mimic the mechanical stiffness of the native tissue. An implant that employs a lattice design can significantly lower the stiffness of a solid structure whilst maintaining strength. This study was conducted to investigate the effect of implementing a porous internal lattice structure with a thin outer shell on the articular contact mechanics, using a radial head hemiarthroplasty. It was hypothesized that …


Elbow Patients’ Data Collection And Analysis: An Examination Of Electromyography Healing Patterns, Raneem Haddara Oct 2016

Elbow Patients’ Data Collection And Analysis: An Examination Of Electromyography Healing Patterns, Raneem Haddara

Electronic Thesis and Dissertation Repository

Musculoskeletal conditions are the most common cause of severe long-term pain and physical disability, accounting for the highest disability costs of about $17 billion yearly. To provide better rehabilitation tactics, the knowledge gap between injuries and their healing mechanisms needs to be addressed. The use of electromyography (EMG) is very popular in detecting neuromuscular diseases or nerve lesions; however, there is limited knowledge available for quantifying healing patterns of EMG in orthopedic patients who have injured their joints, muscles, or bones. In order to quantify the progress of orthopedic patients and assess their neuromuscular health and muscle synergy patterns, EMG …


An Image-Based Tool To Examine Joint Congruency At The Elbow, Emily A. Lalone Sep 2012

An Image-Based Tool To Examine Joint Congruency At The Elbow, Emily A. Lalone

Electronic Thesis and Dissertation Repository

Post-traumatic osteoarthritis commonly occurs as a result of a traumatic event to the articulation. Although the majority of this type of arthritis is preventable, the sequence and mechanism of the interaction between joint injury and the development of osteoarthritis (OA) is not well understood. It is hypothesized that alterations to the joint alignment can cause excessive and damaging wear to the cartilage surfaces resulting in OA. The lack of understanding of both the cause and progression of OA has contributed to the slow development of interventions which can modify the course of the disease. Currently, there have been no reported …


The Contact Mechanics And Kinematics Of Radial Head Implants, Hannah L. Shannon Aug 2012

The Contact Mechanics And Kinematics Of Radial Head Implants, Hannah L. Shannon

Electronic Thesis and Dissertation Repository

A number of commercially available radial head (RH) implants are used for the management of RH fractures. The optimal shape of a RH implant to restore joint mechanics to the native state has not been established. This work compares radiocapitellar contact and kinematics for three implant designs as well as the native RH. These implants include an axisymmetric, a quasi-anatomic and a patient-specific design. When compared to the native RH, only the axisymmetric implant was significantly different in contact area (p=0.008). Active and passive forearm supination was assessed for differences in translations of the RH. Significant differences were found in …