Optical Fibre-Based Force Sensing Needle Driver For Minimally Invasive Surgery, Pouya Soltani Zarrin Dec 2017

Optical Fibre-Based Force Sensing Needle Driver For Minimally Invasive Surgery, Pouya Soltani Zarrin

Electronic Thesis and Dissertation Repository

Minimally invasive surgery has been limited from its inception by insufficient haptic feedback to surgeons. The loss of haptic information threatens patients safety and results in longer operation times. To address this problem, various force sensing systems have been developed to provide information about tool–tissue interaction forces. However, the provided results for axial and grasping forces have been inaccurate in most of these studies due to considerable amount of error and uncertainty in their force acquisition method. Furthermore, sterilizability of the sensorized instruments plays a pivotal role in accurate measurement of forces inside a patient's body. Therefore, the objective of …


Design, Implementation And Control Of A Robotic Platform For Post-Stroke Upper- And Lower-Limb Rehabilitation, Vahid Mehrabi Dec 2017

Design, Implementation And Control Of A Robotic Platform For Post-Stroke Upper- And Lower-Limb Rehabilitation, Vahid Mehrabi

Electronic Thesis and Dissertation Repository

Stroke is the primary cause of permanent disabilities worldwide. Hemiparesis and hemiplegia (the most common consequences of stroke) are the decreases in motor-functionality of the brain on one side of the body which will affect the daily life activities of the patient. There are several challenges with the current state of delivering rehabilitation services such as limitations on the number of the clinics, financial resources needed for providing rehabilitation, associated costs of transportation, and human resources. To overcome the issues related to conventional ways of delivering therapy, different robotic systems have been developed to benefit healthcare systems and patient with …


A 3d Us Guidance System For Permanent Breast Seed Implantation: Development And Validation, Justin Michael Nov 2017

A 3d Us Guidance System For Permanent Breast Seed Implantation: Development And Validation, Justin Michael

Electronic Thesis and Dissertation Repository

Permanent breast seed implantation (PBSI) is a promising breast radiotherapy technique that suffers from operator dependence. We propose and have developed an intraoperative 3D ultrasound (US) guidance system for PBSI.

A tracking arm mounted to a 3D US scanner registers a needle template to the image. Images were validated for linear and volumetric accuracy, and image quality in a volunteer. The tracking arm was calibrated, and the 3D image registered to the scanner. Tracked and imaged needle positions were compared to assess accuracy and a patient-specific phantom procedure guided with the system.

Median/mean linear and volumetric error was ±1.1% and …


Design And Evaluation Of Neurosurgical Training Simulator, Trinette L. Wright Nov 2017

Design And Evaluation Of Neurosurgical Training Simulator, Trinette L. Wright

Electronic Thesis and Dissertation Repository

Surgical simulators are becoming more important in surgical training. Consumer smartphone technology has improved to allow deployment of VR applications and are now being targeted for medical training simulators. A surgical simulator has been designed using a smartphone, Google cardboard 3D glasses, and the Leap Motion (LM) hand controller. Two expert and 16 novice users were tasked with completing the same pointing tasks using both the LM and the medical simulator NeuroTouch. The novice users had an accuracy of 0.2717 bits (SD 0.3899) and the experts had an accuracy of 0.0925 bits (SD 0.1210) while using the NeuroTouch. Novices and …


Development Of An Active Finger Motion Simulator: With In-Vitro Assessments Of Tendon Loads And Joint Kinematics, Mohammad Haddara Nov 2017

Development Of An Active Finger Motion Simulator: With In-Vitro Assessments Of Tendon Loads And Joint Kinematics, Mohammad Haddara

Electronic Thesis and Dissertation Repository

Musculoskeletal injuries of the finger far outnumber those of other joints, and while in-vitro motion simulators are useful for studying joint biomechanics and evaluating surgical repairs, considerably less simulator development has been reported for the finger compared to other joints. Replication of active musculoskeletal movement during in-vitro testing has been shown to be more representative of in-vivo motion patterns, and closed-loop motion controllers are the current state-of-the-art for in-vitro kinematics studies. However, an in-vitro motion simulator with closed-loop tendon load control and simultaneous tendon excursion control has not yet been reported for the finger. This thesis outlines the design and …


Functional Design And Analysis Of A Linked Shoulder Prosthesis, Emily West Nov 2017

Functional Design And Analysis Of A Linked Shoulder Prosthesis, Emily West

Electronic Thesis and Dissertation Repository

Persistent shoulder instability following joint arthroplasty remains a concern with mixed outcomes following clinical and surgical intervention. Thus, a linked universal joint implant was developed and functionally analyzed. A virtual model of the linked implant was developed and implanted in a 3D bony specimen to measure the available circumduction range of motion. Stresses in the implant were estimated using finite element analysis based on joint loads during activities of daily life. The glenoid fixation stress was evaluated using finite element analysis.

The implant was capable of restoring normal range of motion, and withstanding expected joint loads without yield or fatigue …


Force Sensing Surgical Grasper With Folding Capacitive Sensor, Dave Bp Tripp Aug 2017

Force Sensing Surgical Grasper With Folding Capacitive Sensor, Dave Bp Tripp

Electronic Thesis and Dissertation Repository

Minimally-invasive surgery (MIS) has brought many benefits to the operating room, however, MIS procedures result in an absence of force feedback, and surgeons cannot as accurately feel the tissue they are working on, or the forces that they are applying. One of the barriers to introducing MIS instruments with force feedback systems is the high cost of manufacturing and assembly. Instruments must also be sterilized before every use, a process that can destroy embedded sensing systems. An instrument that can be disposed of after a single use and produced in bulk at a low cost is desirable. Printed circuit micro-electro-mechanical …


Real-Time Membrane Puncture Detection Using Force Sensors For Micro-Injections In Phantoms, Szymon Kowal Jun 2017

Real-Time Membrane Puncture Detection Using Force Sensors For Micro-Injections In Phantoms, Szymon Kowal

Electronic Thesis and Dissertation Repository

Micro-manipulators provide tools for researchers to improve workflow in common preclinical and clinical applications. Following drug delivery injections where drugs did not reach their target will squander research time, experimental animals and other resources. An ultrasound-guided robot developed at Robarts Research Institute was revised to implement closed-loop force feedback to compensate for tissue deformation during micro-interventions. Force sensors can detect puncture events as the needle penetrates tissue membranes, thereby reducing damage to surrounding tissues by preventing the needle from overshooting its target. Changing the angle of injection determined that the range of detectable forces during injections into tissue-mimicking phantoms suggests …


Assessment Of The Non-Linear Stress-Strain Characteristics Of Poly (Vinyl Alcohol) Cryogel, Mojdeh Zakeri Mar 2017

Assessment Of The Non-Linear Stress-Strain Characteristics Of Poly (Vinyl Alcohol) Cryogel, Mojdeh Zakeri

Electronic Thesis and Dissertation Repository

Creation of tissue-mimicking constructs is of great importance in the field of biomedical engineering. Poly (vinyl Alcohol) (PVA) is a biomaterial capable of simulating a wide range of geometries and mechanical properties of biological tissues. It is nontoxic, biocompatible, and easy to produce. PVA can be physically crosslinked by repeated cycles of freezing and thawing. The final product of this process is called PVA cryogel (PVA-C). The mechanical properties of PVA-C can be accurately controlled by changing PVA molecular weight, PVA concentration, and number and duration of freeze/thaw cycles (FTC). In this study, the stress-strain behavior of PVA cryogel was …


Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell Jan 2017

Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell

Electronic Thesis and Dissertation Repository

Magnetic Resonance Imaging (MRI) is an indispensable, non-invasive diagnostic tool for the assessment of disease and function. As an investigational device, MRI has found routine use in both basic science research and medicine for both human and non-human subjects.

Due to the potential increase in spatial resolution, signal-to-noise ratio (SNR), and the ability to exploit novel tissue contrasts, the main magnetic field strength of human MRI scanners has steadily increased since inception. Beginning in the early 1980’s, 0.15 T human MRI scanners have steadily risen in main magnetic field strength with ultra-high field (UHF) 8 T MRI systems deemed to …