Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

California Polytechnic State University, San Luis Obispo

ASET

Articles 1 - 30 of 65

Full-Text Articles in Engineering

Analysis Of Scramento State University Union, Zachary Schuler Jun 2023

Analysis Of Scramento State University Union, Zachary Schuler

Fire Protection Engineering: Culminating Experience Project Reports

Sacramento State Union is a centrally located building with a large occupant load during the school year. This building is a 239,000-square-foot three-story structure built originally back in 1975. This original building was constructed using waffle slab construction. Additions in 1996 and 2016 were built using steel beam and girder construction to meet the total square footage we have today. This mixed-use occupancy is not only a congregation point, but many events are held in this building as well.

In this analysis of the building, fire life safety systems are reviewed and determined if they not only meet the minimum …


Building San Francisco, Ca, Kevin Nguyen Jun 2023

Building San Francisco, Ca, Kevin Nguyen

Fire Protection Engineering: Culminating Experience Project Reports

The objective of this report is to conduct a thorough analysis and evaluation of the existing fire life safety and fire protection systems in place at the Building located in San Francisco, California. The building is classified as a Type II-A building and serves predominantly as office space. The building is six stories tall with a total gross area of approximately 97,170 SF.

The initial portion of this report concentrates on a thorough prescriptive-based analysis, which provides an evaluation of the egress design, fire alarm system, communication systems, fire suppression system, structural and construction design, smoke control, and flammability requirements. …


Process Support Building Savannah River Site, Victoria Zawacki Jun 2022

Process Support Building Savannah River Site, Victoria Zawacki

Fire Protection Engineering: Culminating Experience Project Reports

A report on the fire and life safety analysis of the Savannah River Site Process Support Building is required in order to receive a Master of Science in Fire Protection Engineering from the California Polytechnic State University, San Luis Obispo. The Process Support Building is a two-story office building that was first occupied in 2013, with a floor area of approximately 10,000 ft2. The building contains mainly personal offices, but also contains conference and turnover rooms, a Computer Simulation Room, an Observation Room, and a lunch area. The analysis includes both prescriptive and performance-based analysis.

The Process Support Building is …


Two-Storey Office Building, Colin Mallett Jun 2022

Two-Storey Office Building, Colin Mallett

Fire Protection Engineering: Culminating Experience Project Reports

This FPE 596 culminating project report was developed to meet the requirements for completion of the Fire Protection Master’s Program at Cal Poly. The report is intended to provide a detailed understanding of fire and building code requirements as well as describe both prescriptive and performance based approaches to human behavior in fire scenarios, building evacuation strategies, egress design and tenability analysis. An overall determination will be made to evaluate if the building provides the expected levels of safety for building occupants from fire.

The office building #211 was designed and constructed to be compliant with the International Building Code …


Grange Insurance Audubon Center-Fire Protection Life Safety Report, Gabriel Levy Jun 2022

Grange Insurance Audubon Center-Fire Protection Life Safety Report, Gabriel Levy

Fire Protection Engineering: Culminating Experience Project Reports

This technical approach narrative presents the intent and methodology of the Fire Protection and Life Safety systems for the Grange Insurance Audubon Center located at 505 W Whittier St. Columbus OH 43215. The primary goal of the structure is to provide life and property protection in a fire scenario while taking into account the costs of implementing the criterion and risks associated with the facility. This will be achieved through the appropriate application of requirements listed in the 2015 International Building Code (IBC) and the International Fire Code (IFC) as adopted by the City of Columbus, Ohio, and any reference …


Fire Safety Management Plan For South Texas Project Turbine Generator Building, Brett Long Jun 2022

Fire Safety Management Plan For South Texas Project Turbine Generator Building, Brett Long

Fire Protection Engineering: Culminating Experience Project Reports

This report includes a fire protection and life safety analysis of the South Texas Project Turbine Generator Building (TGB). This analysis was done to fulfill the requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. The Turbine Generator Building consists of three elevations and is Type II-B construction. The TGB’s primary use is a special-purpose industrial building housing the turbine generator, main feed pumps, condensate pumps, condenser, feed water re-heaters, secondary cold chemistry lab, Balance-of-Plant (BOP) diesel, batteries, and switchgear, 13.8 kVA switchgear, and various other systems and components. This analysis consists of …


Fire Protection And Life Safety Analysis Of Christopher Cohan Center, Kristen Dentici Jun 2022

Fire Protection And Life Safety Analysis Of Christopher Cohan Center, Kristen Dentici

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the fire protection and life safety systems of the Christopher Cohan Center. The building was assessed from both a prescriptive and performance-based approach.

The prescriptive design analyzed the code requirements for the building based on the 2018 IBC, with some consideration for the codes in place at the time of construction. The prescriptive analysis main focus was on egress systems, fire alarm and detection, fire suppression, and structural fire protection. The egress analysis found that the exits and exit configuration were sufficient for the occupant loads that were calculated for the building. The fire alarm and detection …


Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal Jun 2022

Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal

Fire Protection Engineering: Culminating Experience Project Reports

This report contains an analysis of the life safety and fire protection features of a four-story apartment building in Maple Grove, Minnesota. The report is a part of the final project intended to meet the requirements for the Culminating Experience of the California Polytechnic Master of Science Fire Protection Engineering Program.

The apartment building chosen for the analysis is a mixed-use four-story wood-framed structure. The first floor of this structure includes office space for building management, a meeting space, and various electrical and mechanical spaces as well as apartments. There are exit stairways on each end of the structure extending …


Mount Sac Gym & Aquatics Center: Fire & Life Safety Report, Alex Hoeft Jun 2022

Mount Sac Gym & Aquatics Center: Fire & Life Safety Report, Alex Hoeft

Fire Protection Engineering: Culminating Experience Project Reports

This report has been prepared to review and analyze the Fire and Life Safety status of the proposed Gym & Aquatics building at Mt. San Antonio College. This was done using two methods: prescriptive and performance based. The prescriptive section examines the explicitly code-mandated requirements for the building and the performance-based section examines implicit requirements for the building based on the goals presented in the Life Safety Code, NFPA 101.

The subject building is a 147,000 square foot, two-story, steel-framed athletics complex occupied primarily for assembly and business uses. The structure has an indoor and outdoor component with two gymnasiums …


College Sports Center Fire Protection Analysis, Elijah Kimmig Jun 2021

College Sports Center Fire Protection Analysis, Elijah Kimmig

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this project was to analyze and compare the existing fire protection systems in the college sports center to current applicable codes and standards. Both prescriptive based analysis and performance based analyses were performed.

The prescriptive based analyses included analyzing the structural fire protection, fire suppression, fire alarm, and egress systems. Overall, the majority of the fire protection systems appeared to meet the requirements of the current codes but there are a few items that were found that appear to not meet current code. These items are listed below along with recommendations to mitigate: (1) Placement of certain …


Fire Protection Analysis For The Tritium Engineering Building, Jack Smeck Jun 2021

Fire Protection Analysis For The Tritium Engineering Building, Jack Smeck

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzed several different aspects of the fire protection and life safety strategy for the Tritium Engineering Building (TEB) at the Savannah River Site in Aiken, SC. The TEB is a single-story, Type IIB building that primarily houses engineering and technical staff. The building is approximately 15,560 ft2 and consists of two large “open areas” enclosed by hard- wall offices. Modular workstations are located in both “open areas” and accommodate the majority of the building occupants. This analysis provided both a prescriptive and a performance-based approach for analyzing fire hazards within the building. The prescriptive- based analysis evaluated the …


Husky Union Building - University Of Washington Fire And Life Safety Overview And Analysis, Dan Quatier Jun 2021

Husky Union Building - University Of Washington Fire And Life Safety Overview And Analysis, Dan Quatier

Fire Protection Engineering: Culminating Experience Project Reports

A fire and life safety analysis was performed on the Husky Union Building, which is the student union building on the campus of the University of Washington in Seattle, WA. This analysis was performed for the fulfillment of requirements for the Master of Science in Fire Protection Engineering degree from California Polytechnic State University San Luis Obispo.

The analysis includes both a prescriptive-based and a performance-based design. The prescriptive analysis includes the following elements: (1) Building Code Overview, (2) Egress Analysis and Design, (3) Fire Alarm and Detection, (4) Water-Based Suppression Systems, and (5) Structural Fire Protection

The prescriptive analysis …


California Polytechnic State University – San Luis Obispo Building 180: Baker, Kelly Kessloff Jun 2021

California Polytechnic State University – San Luis Obispo Building 180: Baker, Kelly Kessloff

Fire Protection Engineering: Culminating Experience Project Reports

This project was performed as part of the requirements for completion of the Fire Protection Engineering Master’s Program at Cal Poly. This project covers a full prescriptive and performance based analysis on the Warren J. Baker Center for Science and Mathematics. This building was constructed on Cal Poly’s campus in 2013 and serves occupancies such as classrooms, laboratories, and office space for students and professors.

The prescriptive based analysis of this report will analyze the applicable building codes and determine if this building is compliant. Relevant codes include the 2016 California Building and the 2016 California Fire Code. In addition …


Fire And Life Safety Analysis: Robert E Kennedy Library, Cal Poly San Luis Obispo Campus, Christopher Olmstead Jun 2020

Fire And Life Safety Analysis: Robert E Kennedy Library, Cal Poly San Luis Obispo Campus, Christopher Olmstead

Fire Protection Engineering: Culminating Experience Project Reports

This report provides a fire safety analysis on the Robert E. Kennedy Library located on the Cal Poly University campus San Luis Obispo, California. In the course of this analysis, a prescriptive and performance-based approached was used. The goal was to review and obtain an understanding of the features of the building’s design and use that provide fire safety. During the analysis, areas of deficiency will be identified. Recommendations will be made based on the analysis and the nature of the deficiencies.

The overall goal is to abide by the NPFA Life Safety standard: (1) Protection of occupants not intimate …


Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton Jun 2020

Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton

Fire Protection Engineering: Culminating Experience Project Reports

The following report contains an analysis of the life safety and fire protection features of a Chicago Hotel. The report is intended to meet the requirements for the Culminating Experience of the Cal Poly Master of Science Fire Protection Engineering Program.

The Chicago Hotel building chosen for the analysis is a mixed-use 7-story hotel. On the 1st, 2nd, and 7th floors of the building are spaces for mercantile and restaurant tenants as well as other spaces necessary for the operation of the building such as back of house space for the hotel, storage, employee locker rooms, hotel and retail lobbies, …


Second Baptist Church, Cypress Campus, David Kalinec Jun 2020

Second Baptist Church, Cypress Campus, David Kalinec

Fire Protection Engineering: Culminating Experience Project Reports

This report was created as part of the Master of Science Fire Protection Engineering degree program at California Polytechnic State University at San Luis Obispo. This project summarized the covered subjects during the course of each quarter of the program. The site chosen for this project is Second Baptist Church, Cypress Campus, located in Cypress, TX. This building was chosen because Churches are mixed use buildings that include assembly occupancies and large occupant loads.

A prescriptive-based code evaluation was performed on the building according to the 2012 editions of the international building code and fire code, adopted at the time …


New Stanford Hospital, Fpe 2020 Student Mar 2020

New Stanford Hospital, Fpe 2020 Student

Fire Protection Engineering: Culminating Experience Project Reports

This report is the compiled culminating project for the Fire Protection Engineering Master’s Program at Cal Poly, SLO. Addressed herein is the fire protection and life safety approach for the New Stanford Hospital in Palo Alto, California in accordance with the 2012 NFPA 101 – Life Safety Code and the 2016 California Building and Fire Codes. This includes review of building occupancies, construction type, fire-resistive ratings, means of egress, and fire protection systems. The objective of this report is to review the impact of major fire scenarios on life, property, and operations.

The New Stanford Hospital is a Type IA …


Silverton Timeshare Tower “The Berkley”, Kevin Murphy Jun 2019

Silverton Timeshare Tower “The Berkley”, Kevin Murphy

Fire Protection Engineering: Culminating Experience Project Reports

The Berkley (aka the Silverton Timeshare Tower) was reviewed for compliance with the code of record. This included review of the full architectural set of drawings, as well as the available Fire Protection Report and Amendments that were issued prior to and during construction. This analysis has been slowly performed throughout the extent of my graduate career at California Polytechnic State University, San Luis Obispo (Cal Poly), and has been in depth for each applicable area of study. Each of the studies performed will be reviewed in the applicable sections below, be it for prescriptive analysis of the existing facility …


Building V: Fire And Life Safety Analysis, Andrew Ko Jun 2019

Building V: Fire And Life Safety Analysis, Andrew Ko

Fire Protection Engineering: Culminating Experience Project Reports

A fire and life safety analysis was completed for Building V as part of a culminating project in the California Polytechnic State University at San Luis Obispo Fire Protection Engineering Master’s Degree Program. This report will detail both a prescriptive design based on the 2013 California Building Code and applicable standards as well as a performance based analysis based on a design fire scenario.

The prescriptive design will discuss four main components of compliance: 1) Structural Fire Protection, 2) Fire Alarm, 3) Fire Sprinkler, and 4) Means of Egress. Structural fire protection analysis is separated into four parts: type of …


Atx Storage: Fire And Life Safety Analysis, Perla Salcedo Jun 2019

Atx Storage: Fire And Life Safety Analysis, Perla Salcedo

Fire Protection Engineering: Culminating Experience Project Reports

The following report is a fire and hazard protection analysis of a new building. This new building is a self-storage building called ATX Storage locate in Austin, TX. The prescriptive requirements set by the codes and standards used at time of construction of the building have been met. The building has been properly classified with respect to occupancy as S1, Group B and R-3 and construction type II A Sprinklered. Appropriate design for interior partitions and exterior wall have been identified. Interior finish requirements have been analyzed for a better understanding of aesthetics guidelines. Based on the sprinkler drawing calculations, …


University Student Services Center, Ivan Orlando Mendoza Jun 2018

University Student Services Center, Ivan Orlando Mendoza

Fire Protection Engineering: Culminating Experience Project Reports

The building was found to be generally compliant with the requirements set forth in the codes and standards, any discrepancies are addressed within the report in their respective sections. The prescriptive-based analysis was performed using the appropriate NFPA standards, the Life Safety Code (LSC) and the International Building Code (IBC).

The building is three storied and has an overall gross floor area of 101,579 sq ft. It is classified as a mixed occupancy use with a calculated total occupant load of 2,866 occupants and is being evaluated as a Type II-B structure as defined in the IBC. It is protected …


Shyh Wang Hall- Lbnl Building 59, Mike Torkelson Jun 2018

Shyh Wang Hall- Lbnl Building 59, Mike Torkelson

Fire Protection Engineering: Culminating Experience Project Reports

This report details the fire and life safety analysis of Shyh Wang Hall, a new building at the Lawrence Berkeley National Laboratory. Wang Hall houses offices, high performance computers, and associated mechanical space. The building is constructed as a Type IIB structure and includes four stories. Both prescriptive-based and performance-based design is considered.

The prescriptive analysis considers the fire and life safety features as required by applicable codes, including the Department of Energy requirements. The building is protected by fire detection and alarm system as well as automatic sprinklers. The prescriptive design meets the code requirements with the possible exception …


Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen Jun 2018

Warren J. Baker Center For Science And Mathematics (Csm)- Fire Protection Analysis, Neal Larsen

Fire Protection Engineering: Culminating Experience Project Reports

Analyzing the fire protection features of the Warren J. Baker Center for Science and Mathematics Building 180, located on Cal Poly Campus in San Luis Obispo California was done using two methods. The prescriptive based analysis of the building focused on the building design, egress, structural fire protection, fire suppression, fire alarm and detection systems to determine if current codes and standards were meet. The performance based analysis discusses certain methods and design fire scenarios that are present within the building and the building’s ability to protect occupants until they can exit safely. The performance based analysis was done using …


Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman Mar 2018

Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis was performed as an academic exercise as part of the MS Fire Protection Engineering Program of California Polytechnic State University, San Luis Obispo. The project is a culminating report with regards to prescriptive based and performance based aspects for the fire and life safety analysis of a project building. These analyses were performed on a building located on a college campus in Southern California and is to remain nameless upon the request of the owner and architect. The building is in the School of Physical Sciences at the University it resides. The building houses …


Building 43: Recreation Center - Cal Poly San Luis Obispo, Daniel Gonzalez Mar 2018

Building 43: Recreation Center - Cal Poly San Luis Obispo, Daniel Gonzalez

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this project is to analyze the Fire Protection systems of the Recreation Center on campus at California Polytechnic State University, San Luis Obispo. Only the building itself is analyzed in this project. This report provides both a prescriptive-based and performance-based analysis of the building. The prescriptive-based analysis includes an overview of the structural components and their fire resistance, the sprinkler system, the fire alarm system, as well as an egress analysis. The performance-based analysis consists of three different potential fire scenarios, with the first being modeled with both Pathfinder and Pyrosim. Resources used are the building’s floor …


Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker Dec 2017

Fire And Life Safety Analysis Of The Production Facility (Pf)- 870, Nolan Baker

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of the fire and life-safety analysis was to perform a prescriptive-based and performance based analysis on the fire and life safety systems in the Production Facility (PF) at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the building met applicable code requirements for existing life safety systems. The performance-based analysis consisted of a series of fire scenarios to ensure the fire and life safety systems allowed adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and the International Building Code (IBC). The occupancy of …


Sandia National Laboratories' Building 858/North Fabrication Facility, Daniel Garcia Dec 2017

Sandia National Laboratories' Building 858/North Fabrication Facility, Daniel Garcia

Fire Protection Engineering: Culminating Experience Project Reports

In this report, a fire protection and fire hazard analysis has been performed on a semi- conductor facility, abbreviated as the Fab, located on Kirtland Air Force Base in Albuquerque, New Mexico. The Fab is part of the MESA complex which is operated by the NTESS Corporation for the Department of Energy (DOE) at Sandia National Laboratories. The prescriptive analysis of this report addresses the various fire protection systems in the facility such as fire suppression, and fire alarm. The prescriptive analysis is based on national codes and standards from the National Fire Protection Association (NFPA) and from the International …


Orfalea College Of Business- Fire & Life Safety Analysis, Napoleon E. Nino Jun 2017

Orfalea College Of Business- Fire & Life Safety Analysis, Napoleon E. Nino

Fire Protection Engineering: Culminating Experience Project Reports

This report details the prescriptive and performance based analyses performed on the Orfalea College of Business building, located on the Cal Poly San Luis Obispo campus. Designed in accordance with the 1985 Uniform Building Code (UBC), this building is evaluated for compliance with the requirements prescribed under relevant codes in place as of 2016. The main function of this building is to serve both academic and administrative purposes, including classrooms and staff offices. Aspects of the building analyzed include: Egress Systems, Structural Fire Protection, Smoke Management, Fire Detection, Fire Notification, and Fire Suppression The prescriptive analysis demonstrates the lack of …


Maumus Center- Fire Protection Engineering Analysis, Tyler Mobley Jun 2017

Maumus Center- Fire Protection Engineering Analysis, Tyler Mobley

Fire Protection Engineering: Culminating Experience Project Reports

This report is a fire protection engineering analysis of the Maumus Center, a science center and planetarium, in Arabi, Louisiana. The objective of this analysis is to outline the code defined requirements and to confirm the minimum level of safety from fire is attained. Analyzed in the report are the design requirements prescribed in the adopted building and life safety codes, and the performance of the prescribed design. The prescriptive review addresses the building construction in regards to fire protection, the means of egress, the water‐based fire suppression system, and the fire alarm system. The performance review incorporates the goals …


Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen Mar 2017

Fire And Safety Analysis Robert E. Kennedy Library, Marius Bjelde Andersen

Fire Protection Engineering: Culminating Experience Project Reports

The Robert E. Kennedy Library is located on Cal Poly Campus. The Library is a five-story building with different occupancies which consists of library areas, offices, mechanical equipment and storage areas. The building has a total area of 178 702 ft². The original code of construction for the Library was the 1976 Uniform Building code (UBC). However, the fire and life safety analysis of the building in this report is performed using: Egress: NFPA 101 LSC 2015, Water based suppression: NFPA 13, Structural fire protection: 2015 IBC, Fire detection, alarm and communication systems: NFPA 72, Performance based design: NFPA 101 …