Full-Text Articles in Engineering

The Effect Of A Triphasic Pulse On Scs To Icd Crosstalk, Ryan James Wensley Jun 2013

The Effect Of A Triphasic Pulse On Scs To Icd Crosstalk, Ryan James Wensley

Master's Theses

It is a known problem that a Spinal Cord Stimulator (SCS) can interact with an Implantable Cardioverter Defibrillator (ICD) when both devices are implanted in the same patient. Interactions between the SCS and ICD can cause inappropriate therapy which can be harmful to the patient. While ICD devices have a distinct narrowband sensing bandwidth, the pulse configurations that current SCS devices deliver were not designed with this frequency region in mind. In this thesis, I recommend a new pulse configuration for SCS devices that will minimize the interaction between the two devices. I produce a theoretical equation for each pulse …


St. Jude Medical: Enhanced Mics (Emics), Devanshi Shah Aug 2010

St. Jude Medical: Enhanced Mics (Emics), Devanshi Shah

Master's Theses

Heart disease is one of the most prevalent diseases in the world. The survival chances for patients with ventricular fibrillation/ventricular tachycardia reduces significantly as time passes without treatment and even after getting timely treatment recurring episode are common. These patients can benefit from an Implantable Cardioverter Defibrillator (ICD) which can monitor heart rhythm and provide immediate treatment. Due to the ever changing physical conditions and disease progression, the ICD needs to collect diagnostic data as well as support programming by the physician. The ICD uses inductive telemetry and radio-frequency telemetry for the communication with the external devices such as a …


Finite Element Modeling Of Icd Lead Silicone Soft-Tips, Jose J. Lepe May 2010

Finite Element Modeling Of Icd Lead Silicone Soft-Tips, Jose J. Lepe

Master's Theses

Although highly underutilized by the medical device industry, Finite Element Analysis (FEA) in the development of new technologies is gaining popularity as regulatory bodies such as the Food and Drug Administration (FDA) begin to require additional proof of safety through scientific methods. Non-linear FEA allows engineers to realistically simulate the mechanical behavior of implants as seen in the in-vitro, or in some cases, the in-vivo configurations. The work presented in this report investigates how computational methods can be used to simulate the interaction of a St. Jude Medical silicone soft-tip as it passes through a Peel-Away Sheath (i.e. introducer). In …


Merlin.Net Automation Of External Reports Verification Process, Gabriel John Wettlaufer Jan 2010

Merlin.Net Automation Of External Reports Verification Process, Gabriel John Wettlaufer

Master's Theses

Merlin.net Patient Care Network is a St. Jude Medical product that is used for remote patient management. The basic concept of Merlin.net is to allow the physician to view patient device follow-up information as well as general patient and device information on a web application. The Merlin.net system also interfaces with the patient and will send them notification if they miss a follow-up. All device information will be collected automatically while the patient is sleeping. This information is sent through a telephone line to a Merlin.net server to process a report package and display the collected information on the Merlin.net …