Forensic Investigation Of Building Failure – The Harbour Cay Condominium Disaster, John Airis Dec 2019

Forensic Investigation Of Building Failure – The Harbour Cay Condominium Disaster, John Airis

Publications and Research

When a building suffers collapse, the U.S. Occupational Safety and Health Administration (OSHA) is tasked with conducting an investigation into the cause. Often OSHA will request technical assistance from the National Institute for Standards and Technology to assist in the forensic technical aspects determining a most probable cause. This forensic effort entails many actions. The Harbour Cay Condominium disaster occurred on March 28, 1981 in Cocoa Beach, Florida. It was a total collapse of a five story reinforced concrete structure during the last stage of roof construction, resulting in 11 deaths and 24 injuries. The investigation report revealed structural design …


Quantification Of Heat Flows Through Building Entrance Doors On A Winter Day, Daeho Kang Sep 2019

Quantification Of Heat Flows Through Building Entrance Doors On A Winter Day, Daeho Kang

Publications and Research

The current methods for the prediction of the heat flow through building entrance doors have been used for years while involved with a certain degree of uncertainty. This paper describes an experimental method that accurately quantified such heat flow. The experiment monitored local environmental parameters in a college building on a cold winter day. The results of the experiment demonstrated that the experimental method is viable to accurately estimate the heat flow throughout the entrance doors and the presence of a vestibule moderated heat losses from the conditioned area. The results will be used for validating the existing methods.


Competence Of A Spray Passive Down-Draft Evaporative Cooling (Pdec) System For Space Cooling, Daeho Kang, Richard K. Strand Sep 2019

Competence Of A Spray Passive Down-Draft Evaporative Cooling (Pdec) System For Space Cooling, Daeho Kang, Richard K. Strand

Publications and Research

A spray PDEC system has been relatively less considered than other passive cooling strategies as one of the viable low-energy solutions in the cooling of buildings while having a great potential in energy savings. This study is intended to evaluate the capability of a spray PDEC system for space cooling. It comprises four simulation scenarios to see the system response and influence of indoor thermal environment when a spray PDEC system is adopted as a primary cooling system in two different climates. The simulation results show that a spray PDEC system causes a substantial variation in the indoor thermal environment …


Analysis Of The System Response Of A Spray Passive Downdraft Evaporative Cooling System, Daeho Kang, Richard K. Strand Jun 2019

Analysis Of The System Response Of A Spray Passive Downdraft Evaporative Cooling System, Daeho Kang, Richard K. Strand

Publications and Research

A spray Passive Downdraft Evaporative Cooling (PDEC) system achieves great savings for space cooling and improves indoor environmental quality by supplying a large amount of fresh outdoor air. As previous studies heavily focused on the energy saving capability of a spray PDEC system due to lack of methods for a detailed analysis, the influence of cool humid supply air from a spray PDEC system in a space in buildings has not been comprehensively studied. This study is intended to evaluate the competence of a spray PDEC system as a primary cooling system in typical spaces in a primary school building …


Solar & Rain Catching Canopy "Urban Oasis 2", Afolabi Ibitoye, Cheriyah Wilmot, Alexander Aptekar, Grzegorz Kosieradzki, Kaiyrgul Sultanova, Jude Vallon Dec 2018

Solar & Rain Catching Canopy "Urban Oasis 2", Afolabi Ibitoye, Cheriyah Wilmot, Alexander Aptekar, Grzegorz Kosieradzki, Kaiyrgul Sultanova, Jude Vallon

Publications and Research

The accumulation of water runoff during rain storms is a major problem in New York City’s combination water systems, forcing water treatment plants to release untreated excess water. To avoid overfilling of the sewer system by this grey water, pocket parks and gardens will be used to absorb the excess rainfall. We will be harnessing nature’s resources with current technologies such as: solar panels combined with rain catching canopies, to beautify the environment, educate the public about sustainability, stimulate growth to local businesses through increased foot traffic and bringing social awareness on environmental issues.

The canopies are designed to collect …


Solar And Rain Catching Canopy. Urban Oasis, Afolabi Ibitoye, Langston Clark, Elena Zimareva, Evan Banks, Alexander Aptekar May 2018

Solar And Rain Catching Canopy. Urban Oasis, Afolabi Ibitoye, Langston Clark, Elena Zimareva, Evan Banks, Alexander Aptekar

Publications and Research

The Urban Oasis is designed to work within existing “pocket parks” in New York City as a combined rainwater collector, personal electronics charging station and resting designation for New Yorkers. Intended to not only lessen the demand on the city power grid by using renewable energy to charge devices, the urban oasis is also intended to mitigate grey water overfill in New York’s combined sewer system and, in general, serve as a model for responsible environmental stewardship in urban areas.

The important technical aspects of the canopy specifically analyzed were:

a) how much rainwater could the canopy be expected to …


Performance Control Of A Spray Passive Down-Draft Evaporative Cooling System, Daeho Kang, Richard K. Strand Mar 2018

Performance Control Of A Spray Passive Down-Draft Evaporative Cooling System, Daeho Kang, Richard K. Strand

Publications and Research

A spray passive down-draft evaporative cooling system has been regarded as a low-energy cooling system that leads significant energy savings in the cooling of buildings. While the energy saving capability of the system has been proven, the ability to control a comfortable indoor environment is still inadequate due to strong climatic dependency. This study seeks viable solutions to advance the control competence of the system by mitigating critical problems of the system to be a reliable cooling application in the cooling of buildings. It proposes potential control strategies for the system and alternative operations. It develops a control algorithm for …


Significance Of Parameters Affecting The Performance Of A Passive Down-Draft Evaporative Cooling (Pdec) Tower With A Spray System, Daeho Kang, Richard K. Strand Jun 2016

Significance Of Parameters Affecting The Performance Of A Passive Down-Draft Evaporative Cooling (Pdec) Tower With A Spray System, Daeho Kang, Richard K. Strand

Publications and Research

PDEC towers with spray systems are known to achieve substantial energy savings. Various parameters such as the wet-bulb depression, the tower height, and the wind speed have been known to be key factors affecting the performance of the system. To date, the significance of these parameters and other important factors have not been adequately treated in the literature. There also has been a lack of models that can successfully investigate potential benefits of the system under various conditions where this particular system could be applicable. To address these critical issues, this study performed a parametric analysis by using a FLUENT …