Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 5 of 5
Full-Text Articles in Engineering
Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack
Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack
Conference Papers
In this study, we recorded the number of Acoustic emission (AE) hits and related AE energy during indentation fracture of cortical bone using a PAC PCI-2 card and pico sensor. A threshold value of 43dB was used to filter premature trigger due to background noise. Registered AE hits had more than one count (threshold crossing). Amplifier gain was set at 40dB with a (0.1-1) MHz band pass filter. 8mm cubes of cortical bones were indented in the longitudinal direction at constant crosshead speed of 1 mm min-1 using a large 2D, 50˚ wedge indenter. We hypothesised that signals occurring as …
An Experimental Technique For Measurement Of Heat Generated During Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack
An Experimental Technique For Measurement Of Heat Generated During Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack
Conference Papers
Orthopaedic bone cutting processes such as osteotomy and hip arthroplasty involve the cutting of one with the aid of various manual and powered cutting instruments including manual and powered bone saws. The extent of surgically induced bone necrosis at the point of the cutting tool and the bone is mainly due to the frictional heat generated by bone cutting. Bone necrosis has an impact on bone regeneration, and the rate of healing of the bone post operation. The threshold temperature for impaired regeneration of bone is in the range of 44°C to 47°C. Overheating also affects the sharpness life of …
Detection Of Microcracks During Bone Cutting Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack
Detection Of Microcracks During Bone Cutting Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack
Conference Papers
Surgeons may use a number of cutting instruments such as osteotomes and chisels to cut bone during operative procedures. The initial loading of cortical bone during the cutting process results in the formation of microcracks in the vicinity of the cutting zone with main crack propagation to failure occurring with continued loading; microcracking acts as a stimulus for main crack formation and has also been shown to occur during the propagation of the main crack. It has also been reported that Acoustic Emission (AE) is generated due to microcrack formation and crack growth, prior to, and during final fracture in …
Sequential Labelling And Acoustic Emission Analysis Of Damage Occurring In Cortical Bone During Indentation Cutting, Ger Reilly, Ashkan Safari, David Taylor, Brendan Mccormack
Sequential Labelling And Acoustic Emission Analysis Of Damage Occurring In Cortical Bone During Indentation Cutting, Ger Reilly, Ashkan Safari, David Taylor, Brendan Mccormack
Conference Papers
When a surgeon uses a wedge shaped blade or an osteotome to cut cortical bone during an operative procedure the bone will fail by a process of microcracking and primary crack propagation. It has previously been observed that crack propagation is dependent on the direction of cutting relative to the main axis of the bone. It has also been observed that microcracks occurring during fracture release acoustic signals that facilitate real-time monitoring of a cutting process. In these novel studies, we labelled damage accumulation during cutting of cortical bone using sequential chelating dyes and we correlated recorded AE signals during …
An Investigation Of The Heat Affected Zone In Cortical Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack, Andrew Macey
An Investigation Of The Heat Affected Zone In Cortical Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack, Andrew Macey
Conference Papers
Surgical procedures such as osteotomy and hip replacement involve the cutting of bone with the aid of various manual and powered cutting instruments including manual and powered bone saws. Frictional rubbing between the blade of the saw and the bone results in the generation of localised heating of the cut bone and increased cutting forces (Ark et al, 1997). Overheating in localised areas can cause bone necrosis and have an impact on the rate of healing of the bone post operation and overheating also affects the sharpness life of the blade. A review of the literature indicates that work has …