Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 13 of 13

Full-Text Articles in Engineering

Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack Dec 2005

Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack

Conference Papers

In this study, we recorded the number of Acoustic emission (AE) hits and related AE energy during indentation fracture of cortical bone using a PAC PCI-2 card and pico sensor. A threshold value of 43dB was used to filter premature trigger due to background noise. Registered AE hits had more than one count (threshold crossing). Amplifier gain was set at 40dB with a (0.1-1) MHz band pass filter. 8mm cubes of cortical bones were indented in the longitudinal direction at constant crosshead speed of 1 mm min-1 using a large 2D, 50˚ wedge indenter. We hypothesised that signals occurring as …


2005 Scholars And Artists Bibliography, Stephen D. Slane Dr., Michael Schwartz Library, Cleveland State University, Friends Of The Michael Schwartz Library Oct 2005

2005 Scholars And Artists Bibliography, Stephen D. Slane Dr., Michael Schwartz Library, Cleveland State University, Friends Of The Michael Schwartz Library

Scholars and Artists Bibliographies

This bibliography was created for the annual Friends of the Michael Schwartz Library Scholars and Artists Reception, recognizing scholarly and creative achievements of Cleveland State University faculty, staff and emeriti. Dr, Steve Slane was the guest speaker.


An Experimental Technique For Measurement Of Heat Generated During Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack Sep 2005

An Experimental Technique For Measurement Of Heat Generated During Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack

Conference Papers

Orthopaedic bone cutting processes such as osteotomy and hip arthroplasty involve the cutting of one with the aid of various manual and powered cutting instruments including manual and powered bone saws. The extent of surgically induced bone necrosis at the point of the cutting tool and the bone is mainly due to the frictional heat generated by bone cutting. Bone necrosis has an impact on bone regeneration, and the rate of healing of the bone post operation. The threshold temperature for impaired regeneration of bone is in the range of 44°C to 47°C. Overheating also affects the sharpness life of …


Detection Of Microcracks During Bone Cutting Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack Sep 2005

Detection Of Microcracks During Bone Cutting Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack

Conference Papers

Surgeons may use a number of cutting instruments such as osteotomes and chisels to cut bone during operative procedures. The initial loading of cortical bone during the cutting process results in the formation of microcracks in the vicinity of the cutting zone with main crack propagation to failure occurring with continued loading; microcracking acts as a stimulus for main crack formation and has also been shown to occur during the propagation of the main crack. It has also been reported that Acoustic Emission (AE) is generated due to microcrack formation and crack growth, prior to, and during final fracture in …


Contrast-Detail Analysis Characterizing Diffuse Optical Fluorescence Tomography Image Reconstruction, Scott C. Davis, Brian W. Pogue, Hamid Dehghani, Keith D. Paulsen Sep 2005

Contrast-Detail Analysis Characterizing Diffuse Optical Fluorescence Tomography Image Reconstruction, Scott C. Davis, Brian W. Pogue, Hamid Dehghani, Keith D. Paulsen

Dartmouth Scholarship

Contrast-detail analysis is used to evaluate the imaging performance of diffuse optical fluorescence tomography (DOFT), characterizing spatial resolution limits, signal-to-noise limits, and the trade-off between object contrast and size. Reconstructed images of fluorescence yield from simulated noisy data were used to determine the contrast-to-noise ratio (CNR). A threshold of CNR=3 was used to approximate a lowest acceptable noise level in the image, as a surrogate measure for human detection of objects. For objects 0.5 cm inside the edge of a simulated tissue region, the smallest diameter that met this criteria was approximately 1.7 mm, regardless of contrast level, and test …


Sequential Labelling And Acoustic Emission Analysis Of Damage Occurring In Cortical Bone During Indentation Cutting, Ger Reilly, Ashkan Safari, David Taylor, Brendan Mccormack Jul 2005

Sequential Labelling And Acoustic Emission Analysis Of Damage Occurring In Cortical Bone During Indentation Cutting, Ger Reilly, Ashkan Safari, David Taylor, Brendan Mccormack

Conference Papers

When a surgeon uses a wedge shaped blade or an osteotome to cut cortical bone during an operative procedure the bone will fail by a process of microcracking and primary crack propagation. It has previously been observed that crack propagation is dependent on the direction of cutting relative to the main axis of the bone. It has also been observed that microcracks occurring during fracture release acoustic signals that facilitate real-time monitoring of a cutting process. In these novel studies, we labelled damage accumulation during cutting of cortical bone using sequential chelating dyes and we correlated recorded AE signals during …


Dynamic Matrix Composition In Engineered Cartilage With Stochastic Supplementation Of Growth Factors, Asit K. Saha, J. (Jagannath) Mazumdar, Sean S. Kohles Jun 2005

Dynamic Matrix Composition In Engineered Cartilage With Stochastic Supplementation Of Growth Factors, Asit K. Saha, J. (Jagannath) Mazumdar, Sean S. Kohles

Mechanical and Materials Engineering Faculty Publications and Presentations

Dynamic extracellular matrix (ECM) synthesis is explored in a hypothesized engineered cartilage construct. Growth (α) and decay (β) rate parameters are developed from a previous engineered cartilage model. The presented mathematical model was constructed from the parameterized experimental data using a deterministic and stochastic examination of ECM synthesis based on a negative feedback control mechanism. A growth factor supplementation is incorporated in a probabilistic mathematical approach. The growth factor component modified an initial deterministic model through a Gaussian white noise fluctuation. As the primary constituents of ECM, the mathematical tool is intended to characterize the probable steady state distribution of …


Automated Migration Analysis Based On Cell Texture: Method & Reliability, Jianfeng Qin, Thomas W. Chittenden, Ling Gao, Justin D D. Pearlman Mar 2005

Automated Migration Analysis Based On Cell Texture: Method & Reliability, Jianfeng Qin, Thomas W. Chittenden, Ling Gao, Justin D D. Pearlman

Dartmouth Scholarship

Background: In this paper, we present and validate a way to measure automatically the extent of cell migration based on automated examination of a series of digital photographs. It was designed specifically to identify the impact of Second Hand Smoke (SHS) on endothelial cell migration but has broader applications. The analysis has two stages: (1) preprocessing of image texture, and (2) migration analysis.

Results: The output is a graphic overlay that indicates the front lines of cell migration superimposed on each original image, with automated reporting of the distance traversed vs. time. Expert preference compares to manual placement of leading …


An Investigation Of The Heat Affected Zone In Cortical Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack, Andrew Macey Jan 2005

An Investigation Of The Heat Affected Zone In Cortical Bone Sawing, Hamid Khalili Parsa, Ger Reilly, Brendan Mccormack, Andrew Macey

Conference Papers

Surgical procedures such as osteotomy and hip replacement involve the cutting of bone with the aid of various manual and powered cutting instruments including manual and powered bone saws. Frictional rubbing between the blade of the saw and the bone results in the generation of localised heating of the cut bone and increased cutting forces (Ark et al, 1997). Overheating in localised areas can cause bone necrosis and have an impact on the rate of healing of the bone post operation and overheating also affects the sharpness life of the blade. A review of the literature indicates that work has …


Robot Assisted Ultrasound Imaged Guided Interstitial Lung Brachytherapy In A Porcine Model, Richard A. Malthaner, Edward Yu, Jerry J. Battista, Chris Blake, Donal Downey, Aaron Fenster Jan 2005

Robot Assisted Ultrasound Imaged Guided Interstitial Lung Brachytherapy In A Porcine Model, Richard A. Malthaner, Edward Yu, Jerry J. Battista, Chris Blake, Donal Downey, Aaron Fenster

Oncology Presentations

We set out to see if permanent interstitial brachytherapy seeds could be safely and reproducibly inserted thoracoscopicaly with the ZEUS Robotic system and intraoperative ultrasound into in-vivo porcine lungs.


Design Of A Wireless System For Patient-Hospital Communication And Result Validation In Point Of Care Testing, John Mcgrory, Owen Lynch, Eugene Coyle Jan 2005

Design Of A Wireless System For Patient-Hospital Communication And Result Validation In Point Of Care Testing, John Mcgrory, Owen Lynch, Eugene Coyle

Conference Papers

This paper discuses mobile phone (cell phone) and wireless applications for linking patients who manage their healthcare outside the hospital using Point of Care Testing (POCT) to hospital information systems (HIS). Certain medical conditions require patients to manage their healthcare by performing on themselves POC testing and act faithfully on the result. This raises quality control issue, as these POC samples and testing procedures are not independently overseen by professional hospital staff. In hospitals, samples taken by clinicians are validated by hi-tech computerised validation systems to ensure plausibility, before physicians rely on them. Patients in the home must often use …


Medical Technology: Contexts And Content In Science And Technology, Michael A. De Miranda, Mark Doggett, Jane T. Evans Jan 2005

Medical Technology: Contexts And Content In Science And Technology, Michael A. De Miranda, Mark Doggett, Jane T. Evans

Architectural and Manufacturing Sciences Faculty Publications

No abstract provided.


Simulations Of Nanopore Formation And Phosphatidylserine Externalization In Lipid Membranes Subjected To A High-Intensity, Ultrashort Electric Pulse, Q. Hu, R. P. Joshi, K. H. Schoenbach Jan 2005

Simulations Of Nanopore Formation And Phosphatidylserine Externalization In Lipid Membranes Subjected To A High-Intensity, Ultrashort Electric Pulse, Q. Hu, R. P. Joshi, K. H. Schoenbach

Bioelectrics Publications

A combined MD simulator and time dependent Laplace solver are used to analyze the electrically driven phosphatidylserine externalization process in cells. Time dependent details of nanopore formation at cell membranes in response to a high-intensity (100kV∕cm), ultrashort (10ns) electric pulse are also probed. Our results show that nanosized pores could typically be formed within about 5ns. These predictions are in very good agreement with recent experimental data. It is also demonstrated that defect formation and PS externalization in membranes should begin on the anode side. Finally, the simulations confirm that PS externalization is a nanopore facilitated event, rather than the …