Impact Of The Municipal Solid Waste Incineration Plant In Warsaw On Air Quality, Robert Oleniacz Dec 2014

Impact Of The Municipal Solid Waste Incineration Plant In Warsaw On Air Quality, Robert Oleniacz

Robert Oleniacz

The only Polish municipal solid waste (MSW) incinerator has been operating within the Municipal Solid Waste Disposal Plant in Warsaw since 2000. In the paper selected results of the air quality impact assessment for this incinerator during an operating period of one year (2008) are presented. With respect to the incinerated waste amounts and emission levels, the analysed period can be considered typical for this facility. Assessment of the air quality impact was carried out by assessing air pollutant emissions in reference to the applicable emission limit values and by modeling atmospheric dispersion of these pollutants. It has been found …


Assessment Of The Impact Of Municipal Waste Incineration Plants On Air Quality And The Possibilities Of Its Reduction, Robert Oleniacz May 2014

Assessment Of The Impact Of Municipal Waste Incineration Plants On Air Quality And The Possibilities Of Its Reduction, Robert Oleniacz

Robert Oleniacz

The planned construction of new municipal waste incineration plants over the next few years in Poland results in protests of local communities, which arise mainly from fear of an increase in the air pollution in its vicinity. These protests extend the investment process and hinder the selection of incineration plant location, but on the other hand they necessitate the use of more efficient solutions to reduce their impact on the air quality.This paper characterizes the world's most widely used technology for municipal solid waste incineration (MSWI) and assesses the possible maximum impact on the air quality of an exemplary MSWI …


Co-Incineration Of Large Quantities Of Alternative Fuels In A Cement Kiln – The Problem Of Air Pollutant Emissions, Robert Oleniacz, Magdalena Kasietczuk Jan 2012

Co-Incineration Of Large Quantities Of Alternative Fuels In A Cement Kiln – The Problem Of Air Pollutant Emissions, Robert Oleniacz, Magdalena Kasietczuk

Robert Oleniacz

Over the last few years, a significant increase in the use of alternative fuels in the Polish cement industry has been observed. These are mainly waste and waste-derived fuels. The national leader in this field is Chełm cement plant (Poland), with the share of alternative fuels in the cement kiln heat balance reaching in 2012 the level of 78.5%. In this paper, an analysis of the emission rate of air pollutants from cement clinkering process in the above-mentioned cement plant in the years 1998–2012 was carried out, using the results of continuous and periodic measurements. The compliance with the emission …


Air Pollution Emissions During Baking Of Semi-Finished Graphite Products In A Tunnel Furnace, Marek Bogacki, Robert Oleniacz, Marian Mazur Jan 2012

Air Pollution Emissions During Baking Of Semi-Finished Graphite Products In A Tunnel Furnace, Marek Bogacki, Robert Oleniacz, Marian Mazur

Robert Oleniacz

The baking of semi-finished graphite products in a tunnel furnace is the source of many air pollutants present in both the gaseous and solid phases. The goal of this study was to assess emission rates into the air of the substances such as: CO, NOx, SO2, H2S, CH4, aliphatic hydrocarbons up to C6, benzene and its homologues (BTEX), total dust and tar substances, and polycyclic aromatic hydrocarbons (PAHs) contained in the dust. The research showed a small time-dependence of the emission rates for the majority of the substances analysed, which is, to a large extent, a result of the long …


Wpływ Procesu Współspalania Odpadów W Piecu Cementowym Na Jakość Powietrza / Impact Of Waste Co-Incineration Process In A Cement Kiln On Air Quality, Robert Oleniacz, Magdalena Kasietczuk Nov 2011

Wpływ Procesu Współspalania Odpadów W Piecu Cementowym Na Jakość Powietrza / Impact Of Waste Co-Incineration Process In A Cement Kiln On Air Quality, Robert Oleniacz, Magdalena Kasietczuk

Robert Oleniacz

The work presents the general requirements for the control of emissions to air from waste co-combustion (co-incineration) plants, with particular emphasis on rotary kilns used for clinker production. Air emissions from the cement kiln during co-combustion of alternative fuels and the impact assessment on air quality are also presented. The object of the study was one of the Polish cement plant, which uses significant amounts of solid waste derived fuels (with over 70% share in the cement kiln heat balance). Assessment of the impact on air quality was made based on the results of the modeling of atmospheric dispersion of …


Assessment Of The Impact Of Using Alternative Fuels In A Cement Kiln On The Emissions Of Selected Substances Into The Air, Robert Oleniacz Jan 2010

Assessment Of The Impact Of Using Alternative Fuels In A Cement Kiln On The Emissions Of Selected Substances Into The Air, Robert Oleniacz

Robert Oleniacz

The chapter presents the results of analyses concerning the impact of using alternative fuels in one of the Polish cement plants on the volume of continuously measured emissions into the air for the following substances: carbon dioxide (CO2), carbon monoxide (CO), nitric oxides (NOx), sulphur dioxide (SO2), hydrogen chloride (HCl), gaseous and volatile organic compounds expressed as total organic carbon (TOC), and total dust. The analyses covered a 15-month period of the operation of a dry cement kiln, approximately 100m-long, equipped with four-stage cyclone exchangers and a calciner, constituting an additional chamber for waste co-combustion. The results obtained confirmed the …


Emisja Zanieczyszczeń Pyłowo-Gazowych Z Procesu Wypalania Półproduktów Grafitowych W Piecu Tunelowym, Marek Bogacki, Robert Oleniacz, Marian Mazur, Przemysław Szczygłowski Jan 2010

Emisja Zanieczyszczeń Pyłowo-Gazowych Z Procesu Wypalania Półproduktów Grafitowych W Piecu Tunelowym, Marek Bogacki, Robert Oleniacz, Marian Mazur, Przemysław Szczygłowski

Robert Oleniacz

The baking of semi-finished graphite products in a tunnel furnace is the source of many air pollutants present in both the gaseous and solid phases. The goal of this study was to assess emission rates into the air of the substances such as: CO, NOx, SO2, H2S, CH4, aliphatic hydrocarbons up to C6, benzene and its homologues (BTEX), total dust and tar substances, and polycyclic aromatic hydrocarbons (PAHs) contained in the dust. The research showed a small time-dependence of the emission rates for the majority of the substances analysed, which is, to a large extent, a result of the long …


Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz Dec 2009

Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz

Robert Oleniacz

In the paper, an assessment of the compliance with air emission limit values and the impact on air quality of one of the largest medical waste incinerators in Poland, with a total capacity of about 300 kg/h (two incineration lines) is presented. The assessment took the results of continuous and periodic measurements of emissions in the plant’s installation over a period of 12 months’ operation into account. For this period, a calculation was performed for the spread of air pollutants emitted by the two operating incineration lines. According to the analysis and calculations, the analysed medical waste incineration plant does …


Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz Dec 2008

Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz

Robert Oleniacz

The research object was a medical waste incineration plant with a flue-gas treatment system based on dry sorption agent injection to combustion gases before a high-efficiency particulate collector. A combustion system was consisted with the fluidized bed reactor (starved air gasifier) and the secondary combustion chamber. As the dry absorbent was used a mixture of high reactive hydrated lime and activated carbon. Activated carbon content in the mixture was 5-10 % by mass. The absorbent was injected in the minimal recommended amount (4-5 kg/h). Applied collector was a ceramic filter with total filtration area of 120 m2 and guaranteed outlet …


Ocena Wielkości Emisji Do Powietrza Z Arcelormittal Poland S.A. Oddział W Krakowie W Odniesieniu Do Standardów Unii Europejskiej, Marian Mazur, Marek Bogacki, Robert Oleniacz Oct 2008

Ocena Wielkości Emisji Do Powietrza Z Arcelormittal Poland S.A. Oddział W Krakowie W Odniesieniu Do Standardów Unii Europejskiej, Marian Mazur, Marek Bogacki, Robert Oleniacz

Robert Oleniacz

The work presents emission factors of main air pollutants for installations of ArcelorMittal Poland S.A. Unit in Krakow (Poland) in comparison with analogous characteristic emissions for iron and steel industry in West Europe. In the comparison four installations (to coke, sinter, pig iron and steel production) were taken into consideration. The emission rates from ArcelorMittal Poland S.A. Unit in Krakow were estimated on the basis of the emission levels and production data from 2004, when took place the most significant production of liquid steel during last several years. As a result of the analysis, most the emission factors (with the …


Air Pollutant Emissions From Process Of Mixing Materials Used For Manufacturing Small Products From Carbon And Graphite, Marian Mazur, Marek Bogacki, Robert Oleniacz, Przemysław Szczygłowski Jan 2008

Air Pollutant Emissions From Process Of Mixing Materials Used For Manufacturing Small Products From Carbon And Graphite, Marian Mazur, Marek Bogacki, Robert Oleniacz, Przemysław Szczygłowski

Robert Oleniacz

The paper characterises the method of preparing the HCC and Rubba-type materials used to manufacture small carbon and graphite products, and the composition of waste gases escaping from the mixers for these materials. For the process of mixing the two materials under examination, two measurement series were completed, mainly covering the period from when the binder was added to the properly pre-heated dry mass until the mixer discharged. The results shown apply only to those substances which occur just in the gaseous phase, that is CO, CO2, O2, H2, aliphatic hydrocarbons (C1-C6) and BTX (benzene, toluene, ethylbenzene and xylene) as …


Ocena Skuteczności Działania Suchego Systemu Oczyszczania Spalin Ze Spalania Odpadów Medycznych Opartego Na Wtrysku Sorbentu Wapniowo-Węglowego, Robert Oleniacz Jan 2008

Ocena Skuteczności Działania Suchego Systemu Oczyszczania Spalin Ze Spalania Odpadów Medycznych Opartego Na Wtrysku Sorbentu Wapniowo-Węglowego, Robert Oleniacz

Robert Oleniacz

The research object was a medical waste incineration plant with a capacity of 150 kg per hour equipped with a flue gas treatment system based on dry sorption process using a lime-carbon reagent with adsorbent removing in high-efficiency particulate collector. As the dry sorption agent was used a mixture of high reactive hydrated lime and activated carbon injected to combustion gases by pneumatic feeder. Activated carbon content in the mixture was 5-10 % by mass. Applied collector was ceramic filter with total filtration area of 120 m2 and guaranteed outlet dust concentration under 5 mg/Nm3. Among others things the aims …


Wpływ Dużej Spalarni Odpadów Przemysłowych I Niebezpiecznych Na Jakość Powietrza, Robert Oleniacz, Lidia Rusztowicz Jan 2007

Wpływ Dużej Spalarni Odpadów Przemysłowych I Niebezpiecznych Na Jakość Powietrza, Robert Oleniacz, Lidia Rusztowicz

Robert Oleniacz

Waste incineration causes unavoidable pollutant emissions to atmosphere and thus negative impact on air quality, but scale of the influence is often exaggerated. In the paper computation results of the atmospheric dispersion of pollutants were presented for one of the largest industrial and hazardous waste incineration plant existing in Poland (processing capacity: 3 ton per hour). These results confirm the fact that the incinerator meets the requirements of best available techniques (BAT) for the waste incineration and its impact on air quality is relatively small. This effect is caused mainly by proper operation of the rotary kiln incinerator, high efficiency …


Analiza Możliwości Ograniczenia Emisji Zanieczyszczeń Powietrza Z Instalacji Spalania Odpadów Medycznych W Tarnowie, Robert Oleniacz Oct 2006

Analiza Możliwości Ograniczenia Emisji Zanieczyszczeń Powietrza Z Instalacji Spalania Odpadów Medycznych W Tarnowie, Robert Oleniacz

Robert Oleniacz

The paper presents initial research of effects of some factors on the amount of gaseous pollutants formation during medical waste incineration in a two-stage starved air fluidised bed reactor. In the research was included the impact of such factors as oxygen contents in flue gases, frequency of waste loading, momentary mass flow of waste and temperature in the secondary combustion chambers. Measurements showed that the waste incineration in large amount periodically caused excessive emissions incomplete combustion products (CO, HC), especially during wrong operation of the combustion system. The work demonstrated that the essential importance for CO and HC formation reducing …


Emisja Zanieczyszczeń Powietrza Z Procesu Grafityzacji Wyrobów Drobnych, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Sep 2006

Emisja Zanieczyszczeń Powietrza Z Procesu Grafityzacji Wyrobów Drobnych, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

The paper presents the research results of the air pollutant emissions from the graphitising process of fine carbon products in the Acheson furnace (discharge capacity 5,5 Mg). Research was performed for two kinds of raw material inputs (based on petroleum coke and pitch coke). Approximately 40-hours measurement series were carried out for each material including mainly such substances like carbon monoxide, hydrocarbons, nitrogen oxides, sulphur dioxide, hydrogen sulphide, carbon disulphide, ammonia, benzene, toluene, xylenes, total dust, tar substances and polycyclic aromatic hydrocarbons. Both average and maximum concentrations and mass streams in the flue gases and average emission factors were presented …


Emisja Zanieczyszczeń Z Procesu Grafityzacji Elektrod Węglowych W Piecach Lwg (Castnera). Cz. 2. Wybrane Substancje Pyłowe, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Jan 2006

Emisja Zanieczyszczeń Z Procesu Grafityzacji Elektrod Węglowych W Piecach Lwg (Castnera). Cz. 2. Wybrane Substancje Pyłowe, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

The measurement results of quantity of dust pollutants originated and emitted to air from LWG (Castner) furnaces during graphitisation process of coal electrodes were presented in the paper. The investigation was carried out for total dust, total tar substances and polycyclic aromatic hydrocarbons (PAHs). The measurements were performed both before and after the flue gas control system (catalytic burning and wet cleaning). Thus changes of the substance concentrations in the gases for the cleaning system were estimated. As a result of the investigation was conclusion that the graphite process of coal electrodes in LWG stoves is not a significant source …


Emisja Zanieczyszczeń Z Pieca Achesona Do Grafityzacji Wyrobów Drobnych, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Jan 2006

Emisja Zanieczyszczeń Z Pieca Achesona Do Grafityzacji Wyrobów Drobnych, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

Research results of the air pollutant emissions from the graphitisation process of fine products in the Acheson electric resistance furnace (discharge capacity 5,5 Mg) were presented in the paper. Research was performed for two kinds of raw material inputs (based on petroleum coke and pitch coke). Approximately 40-hours measurement series were carried out for each material including mainly such substances like carbon monoxide, hydrocarbons, nitrogen oxides, sulphur dioxide, hydrogen sulphide, carbon disulphide, ammonia, benzene, toluene, xylenes, total dust, tar substances and polycyclic aromatic hydrocarbons. Both average and maximum concentrations and mass streams in the flue gases and average emission factors …


Emisja Zanieczyszczeń Ze Spalania Odpadów Podestylacyjnych Z Produkcji Witaminy C W Piecu Fluidalnym, Robert Oleniacz Jan 2005

Emisja Zanieczyszczeń Ze Spalania Odpadów Podestylacyjnych Z Produkcji Witaminy C W Piecu Fluidalnym, Robert Oleniacz

Robert Oleniacz

Some results of continuous or periodical measurements of selected air pollutant concentrations and mass streams in the flue gases from liquid waste incineration in a fluidized bed incinerator were presented in the paper. During the researches distillation tails from vitamin C production, that is waste traces from regeneration such solvents as for example ethylene chloride, chloroform or trichloroethylene were incinerated. As a result of the researches there was determined optimal temperature of the fluidized bad in which the waste incineration should be carried out to minimization of CO and NOx formation. Required effectiveness of HCl removal from combustion gases to …


Emisja Zanieczyszczeń Z Procesu Grafityzacji Elektrod Węglowych W Piecach Lwg (Castnera). Cz. 1. Wybrane Substancje Gazowe, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Jan 2005

Emisja Zanieczyszczeń Z Procesu Grafityzacji Elektrod Węglowych W Piecach Lwg (Castnera). Cz. 1. Wybrane Substancje Gazowe, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

The results of measurements of quantity pollutants originated and emitted to air from LWG (Castner) furnaces were introduced. The investigation was carried out during the graphitisation process of coal electrodes, until moment of end of ventilation the stove across applied installations of cleaning of cool gases (catalytic burning and the wet desulphurization). The measurement results of CO, CO2, HC+H2, SO2, H2S, CS2, NO, NO2, NH3 as well as chosen hydrocarbons (C1-C6) and aromatic hydrocarbons (BTX) were presented. In result of conducted investigations was qualified courses of changeability of concentrations in gases these substances before and for the cleaning system. The …


Emisja Chlorowodoru Ze Spalania Węgla W Kotle Pyłowym, Marian Mazur, Robert Oleniacz, Przemysław Szczygłowski, Marek Bogacki Dec 2004

Emisja Chlorowodoru Ze Spalania Węgla W Kotle Pyłowym, Marian Mazur, Robert Oleniacz, Przemysław Szczygłowski, Marek Bogacki

Robert Oleniacz

Emission of hydrogen chloride (HCl) from coal combustion is not controlled just like for example sulpfur dioxide emission. But HCl emission is also important, because chlorine content in some types of coal can reach the similar level to sulfur content. In the paper the measurement results of HCl emission to the air during combustion of three types of coal with law content of chlorine were presented. The researches were carried out for a steam pulverized coal boiler (max. boiler efficiency – 430 t/h) during three various loads (respectively 65, 80 and 95 % of maximum efficiency) without flue gas desulfurization. …


Emisja Btx Towarzysząca Produkcji Wyrobów Węglowych I Grafitowych, Marian Mazur, Przemysław Szczygłowski, Robert Oleniacz, Marek Bogacki Oct 2004

Emisja Btx Towarzysząca Produkcji Wyrobów Węglowych I Grafitowych, Marian Mazur, Przemysław Szczygłowski, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The work presents results of direct measurements of benzene, toluene, ethyl benzene and xylenes (BTX or BTEX) emissions to the air from technological processes related with carbon and graphite manufacturing. The most important from all mentioned pollutants is benzene considered as one of the main factor of air pollution in the European Union. The highest concentrations of BTX were found in the fumes emitted from the tanks of liquid raw materials, while the highest levels of their emissions were from furnaces used for baking of green electrodes and other carbon products.

English title: BTX emission from production of graphite and …


Wpływ Wybranych Parametrów Na Wielkość Emisji Zanieczyszczeń Powietrza Z Procesu Wysokotemperaturowego Spalania Odpadów Chloroorganicznych, Robert Oleniacz Jun 2004

Wpływ Wybranych Parametrów Na Wielkość Emisji Zanieczyszczeń Powietrza Z Procesu Wysokotemperaturowego Spalania Odpadów Chloroorganicznych, Robert Oleniacz

Robert Oleniacz

In the paper preliminary analysis of the continuous measurements of the air pollutants emission and other

parameters of high-temperature process of chloroorganic waste incineration (liquid injection incinerator - Vicarb technology) are presented. In the analysis there was taken especially note of the parameters influencing the emissions, which could significantly vary in the incineration system (for example the amount of incinerated wastes) and pollutants like hydrogen chloride, nitrogen oxides and carbon monoxide. Basing the results of the analysis, it was affirmed that chlorine plays an inhibiting role on the formation of nitrogen oxides in the chloroorganic waste incineration system. On the …


Ocena Funkcjonowania Instalacji Oczyszczania Gazów Odlotowych Z Procesu Grafityzacji Elektrod Węglowych W Sgl Carbon S.A. W Nowym Sączu, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Aug 2003

Ocena Funkcjonowania Instalacji Oczyszczania Gazów Odlotowych Z Procesu Grafityzacji Elektrod Węglowych W Sgl Carbon S.A. W Nowym Sączu, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

The paper presents a general analysis of the suitability of individual elements of the flue-gas treatment system used in SGL Carbon SA in Nowy Sacz (Poland) for the graphitization process carried out in new LWG furnaces (Castner type). The flue-gas treatment system consisted of two installations: catalytic afterburning and flue-gas desulfurization. The analysis of the suitability of various methods of flue-gas treatment was based primarily on the assessment of the effects of their application, including the reduction of concentrations of selected components in post-graphitizing gases. The work also summarizes the results of evaluation of the functioning of the whole flue-gas …


Spalanie Odpadów Chloroorganicznych Z Produkcji Chlorku Winylu Jako Źródło Emisji Zanieczyszczeń Powietrza, Robert Oleniacz Jan 2003

Spalanie Odpadów Chloroorganicznych Z Produkcji Chlorku Winylu Jako Źródło Emisji Zanieczyszczeń Powietrza, Robert Oleniacz

Robert Oleniacz

Production of vinyl chloride is a source of formation of significant gaseous, liquid and solid streams of chlorinated organic wastes containing up to 90 % of chlorine. One of the methods of chlorine recovery from the wastes is incineration. During the waste incineration chlorine released into the flue gases mainly in the form of hydrogen chloride (HCl). The article presents, among others, results of continuous and periodic measurement of concentrations of air pollutants in combustion gases emitted from one of the industrial installations for high-temperature incineration of chlorinated wastes, equipped with effective flue-gas treatment system and recovery of HCl. Data …


Termiczne Przekształcanie Odpadów Medycznych W Instalacji Fluidalnej Firmy Seghers – Emisja Zanieczyszczeń Gazowych I Możliwości Jej Ograniczenia, Robert Oleniacz Jan 2003

Termiczne Przekształcanie Odpadów Medycznych W Instalacji Fluidalnej Firmy Seghers – Emisja Zanieczyszczeń Gazowych I Możliwości Jej Ograniczenia, Robert Oleniacz

Robert Oleniacz

The paper presents the results of measurements of concentrations and mass streams of selected components in the flue gases from the thermal treatment of medical waste in the Seghers incinerator based on fluidized bed reactor.

The tests were carried out at the measuring points located both before and after of the flue-gas cleaning system based on the injection of dry hydrated lime and carbon sorbent and a ceramic filter. In this way it was possible to determine the effectiveness of the removal of selected air pollutants in the dry cleaning system. Analysis of the results of measurements made ​​it possible …


Przebieg Zmienności Stężeń Wybranych Zanieczyszczeń W Gazach Odlotowych Z Procesu Mokrego Gaszenia Koksu, Marian Mazur, Robert Oleniacz, Marek Bogacki Dec 2002

Przebieg Zmienności Stężeń Wybranych Zanieczyszczeń W Gazach Odlotowych Z Procesu Mokrego Gaszenia Koksu, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

Continuous measurement results of selected constituent concentrations in the gases emitted to the air during the coke wet quenching process were presented and discussed in the paper. The measurements were carried out for the standard wet quenching tower. The research covered such substances as carbon dioxide, carbon monoxide, hydrogen sulfide, nitrogen oxide, nitrogen dioxide and a total content of hydrocarbons and hydrogen (combustible gases). Changeability of the substance concentrations depending of the quenching process duration was analyzed. Among other things the beginning of these substances formation, appearance of the maximum and the range of observed concentrations were taken into consideration. …


Weryfikacja Emisji Pyłowej Z Huty Katowice I Zasięgu Jej Oddziaływania, Marian Mazur, Robert Oleniacz, Marek Bogacki, Agnieszka Łopata Jun 2002

Weryfikacja Emisji Pyłowej Z Huty Katowice I Zasięgu Jej Oddziaływania, Marian Mazur, Robert Oleniacz, Marek Bogacki, Agnieszka Łopata

Robert Oleniacz

Preliminary analysis of the results of atmospheric dispersion modeling for dust emission from the Katowice Steelworks (Poland) showed necessity of verification the particulate matter, lead and cadmium emission from the plant. The verification was limited to the substance emission sources influencing air pollution to the largest extent. Both scale of dust emission and its granulometric and chemical composition were re-evaluated. Further calculations of the air propagation for the pollutants were carried out and calculation results were compared with direct measurements. Thus the Katowice Steelworks impact on air quality and the level of total dust, lead and cadmium ground deposition was …


Czynniki Wpływające Na Skład Spalin I Wielkość Emisji Zanieczyszczeń Z Procesów Termicznego Przekształcania Odpadów Niebezpiecznych, Robert Oleniacz Oct 2001

Czynniki Wpływające Na Skład Spalin I Wielkość Emisji Zanieczyszczeń Z Procesów Termicznego Przekształcania Odpadów Niebezpiecznych, Robert Oleniacz

Robert Oleniacz

The work summarizes factors influencing on air emissions from various full-scale hazardous waste incinerators (rotary kiln, multiple hearth furnace, starved-air incinerator, fluidized bed incinerator, liquid injection incinerator). Air pollutant emissions from hazardous waste incineration can be minimized not only by flue-gas cleaning. There are many factors that influence on flue-gas composition and the quantity of air pollutants formed during incineration: the type, the composition and the quantity of waste, the way of waste introducing to the incinerator, excess air ratio, combustion temperature, retention time of exhaust gases etc. Special attention was paid to the loading of waste and incineration conditions …


Struktura Emisji Związków Fluoru Z Hutnictwa Żelaza Na Przykładzie Huty Katowice, Marian Mazur, Robert Oleniacz, Marek Bogacki Jun 2000

Struktura Emisji Związków Fluoru Z Hutnictwa Żelaza Na Przykładzie Huty Katowice, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

As recently as a dozen or so years ago ferrous metallurgy was known as one of the biggest source of fluorine compound emissions to the atmosphere. Nevertheless production technology and raw material changes occurring in this industry cause continuous decreasing of their participation in the total fluorine emission. On the ground of investigations that have been carried out in the Katowice Steelworks (Poland) in the last few years, participation of particular technological processing in the water-soluble fluorine compound emissions (which are regarded as toxic) were presented in the paper, as well as a position of fuel combustion process (that take …


Pirolityczne Metody Utylizacji Odpadów Niebezpiecznych - Przykładowe Rozwiązania I Emisja Zanieczyszczeń, Robert Oleniacz Jun 1999

Pirolityczne Metody Utylizacji Odpadów Niebezpiecznych - Przykładowe Rozwiązania I Emisja Zanieczyszczeń, Robert Oleniacz

Robert Oleniacz

The paper presents the pyrolysis and gasification processes of organic matter and the main directions of their use for the thermal disposal of hazardous waste. Used for this purpose the basic technical solutions are discussed with regard to existing and new technologies. Given the fact that the pyrolytic methods in Poland were primarily used for the incineration of medical waste, most attention was paid to a facility designated for such waste disposal. The problem of air pollutant emissions from this type of installation and some operating guidelines was also presented on the basis of the literature analyses and own research. …