Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Transcranial magnetic stimulation (TMS) (2)
- 4D flow MRI (1)
- Alginate (1)
- Aorta (1)
- Artificial intelligence (1)
-
- B-catenin (1)
- Biomaterials (1)
- Bioprinting (1)
- Bone Biology (1)
- Brain Computer Interface (1)
- Brain Stimulation (1)
- Cardiac (1)
- Cardiovascular (1)
- Chitin (1)
- Corticomotor excitability (1)
- Current direction (1)
- DENSE MRI (1)
- Devices (1)
- Dry Powder Inhaler (DPI) (1)
- EEG (1)
- Emotion (1)
- Fibrosis (1)
- Flexible biodevices (1)
- Focal Adhesion (1)
- Gelatin (1)
- High Flow Nasal Cannula (HFNC) (1)
- High efficiency (1)
- Human Machine Interaction (1)
- Hydroxyapaite (1)
- Inhalation therapy (1)
- Publication Type
Articles 1 - 12 of 12
Full-Text Articles in Engineering
Quantitative Assessment Of Intra- And Inter-Modality Deformable Image Registration Of The Heart, Left Ventricle, And Thoracic Aorta On Longitudinal 4d-Ct And Mr Images, Alireza Omidi, Elisabeth Weiss, John S. Wilson, Mihaela Rosu-Bubulac
Quantitative Assessment Of Intra- And Inter-Modality Deformable Image Registration Of The Heart, Left Ventricle, And Thoracic Aorta On Longitudinal 4d-Ct And Mr Images, Alireza Omidi, Elisabeth Weiss, John S. Wilson, Mihaela Rosu-Bubulac
Biomedical Engineering Publications
Purpose
Magnetic resonance imaging (MRI)-based investigations into radiotherapy (RT)-induced cardiotoxicity require reliable registrations of magnetic resonance (MR) imaging to planning computed tomography (CT) for correlation to regional dose. In this study, the accuracy of intra- and inter-modality deformable image registration (DIR) of longitudinal four-dimensional CT (4D-CT) and MR images were evaluated for heart, left ventricle (LV), and thoracic aorta (TA).
Methods and materials
Non-cardiac-gated 4D-CT and T1 volumetric interpolated breath-hold examination (T1-VIBE) MRI datasets from five lung cancer patients were obtained at two breathing phases (inspiration/expiration) and two time points (before treatment and 5 weeks after initiating RT). Heart, LV, …
Estimating Affective States In Virtual Reality Environments Using The Electroencephalogram, Meghan R. Kumar
Estimating Affective States In Virtual Reality Environments Using The Electroencephalogram, Meghan R. Kumar
Theses and Dissertations
Recent interest in high-performance virtual reality (VR) headsets has motivated research efforts to increase the user's sense of immersion via feedback of physiological measures. This work presents the use of electroencephalographic (EEG) measurements during observation of immersive VR videos to estimate the user's affective state. The EEG of 30 participants were recorded as each passively viewed a series of one minute immersive VR video clips and subjectively rated their level of valence, arousal, dominance, and liking. Correlates between EEG spectral bands and the subjective ratings were analyzed to identify statistically significant frequencies and electrode locations across participants. Model feasibility and …
Effect Of Stimulus Waveform On Transcranial Magnetic Stimulation Metrics In Proximal And Distal Arm Muscles, Christopher Lynch
Effect Of Stimulus Waveform On Transcranial Magnetic Stimulation Metrics In Proximal And Distal Arm Muscles, Christopher Lynch
Theses and Dissertations
Objectives: The purpose of this study was to determine the effect of common transcranial magnetic stimulation (TMS) waveforms (monophasic and biphasic) on resting motor threshold (RMT), active motor threshold (AMT), and motor evoked potential (MEP) amplitudes in the biceps and first dorsal interosseous (FDI) because waveforms may affect motor targets differently. Additionally, we determined the test-retest reliability of TMS metrics for each stimulation type and muscle.
Methods: Ten individuals participated in two sessions of single-pulse TMS delivered to the motor cortex perpendicular to the central sulcus. MEPs were normalized to the maximum EMG signal during contraction and were recorded at …
Nature-Inspired Material Strategies Towards Functional Devices, Sayantan Pradhan
Nature-Inspired Material Strategies Towards Functional Devices, Sayantan Pradhan
Theses and Dissertations
Naturally sourced, renewable biomaterials possess outstanding advantages for a multitude of biomedical applications owing to their biodegradability, biocompatibility, and excellent mechanical properties. Of interest in this dissertation are silk (protein) and chitin (polysaccharide) biopolymers for the fabrication of functional biodevices. One of the major challenges restricting these materials beyond their traditional usage as passive substrate materials is the ability to combine them with high-resolution fabrication techniques. Initial research work is directed towards the fabrication of micropatterned, flexible 2D substrates of silk fibroin and chitin using bench-top photolithographic techniques. Research is focused on imparting electrochemical properties to silk proteins using conducting …
Intermittent Theta Burst Stimulation: Application To Spinal Cord Injury Rehabilitation And Computational Modeling, Neil Mittal
Intermittent Theta Burst Stimulation: Application To Spinal Cord Injury Rehabilitation And Computational Modeling, Neil Mittal
Theses and Dissertations
Loss of motor function from spinal cord injuries (SCI) results in loss of independence. Rehabilitation efforts are targeted to enhance the ability to perform activities of daily living (ADLs), but outcomes from physical therapy alone are often insufficient. Neuromodulation techniques that induce neuroplasticity may push the limits on recovery. Neuromodulation by intermittent theta burst transcranial magnetic stimulation (iTBS) induces neuroplasticity by increasing corticomotor excitability, though this has most frequently been studied with motor targets and on individuals not in need of rehabilitation. Increased corticomotor excitability is associated with motor learning. The response to iTBS, however, is highly variable and unpredictable, …
Applied Machine Learning In Extrusion-Based Bioprinting, Shuyu Tian
Applied Machine Learning In Extrusion-Based Bioprinting, Shuyu Tian
Theses and Dissertations
Optimization of extrusion-based bioprinting (EBB) parameters have been systematically conducted through experimentation. However, the process is time and resource-intensive and not easily translatable across different laboratories. A machine learning (ML) approach to EBB parameter optimization can accelerate this process for laboratories across the field through training using data collected from published literature. In this work, regression-based and classification-based ML models were investigated for their abilities to predict printing outcomes of cell viability and filament diameter for cell-containing alginate and gelatin composite hydrogels. Regression-based models were investigated for their ability to predict suitable extrusion pressure given desired cell viability when keeping …
A Mechanism Behind The Mechanotransduction Of Surface Characteristics In Osteoblasts, Otto J. Juhl Iv
A Mechanism Behind The Mechanotransduction Of Surface Characteristics In Osteoblasts, Otto J. Juhl Iv
Theses and Dissertations
Biomaterials for use in bone regeneration and healing range from metal and metal alloy implants to hydrogel-based solutions. These materials can be optimized to increase bone healing and integration by improving the mechanical and biological properties. Regardless of the material itself, the cell-substrate interaction is key to the success of the biomaterial once implanted. Substrate surface characteristics such as roughness, wettability, and particle density are well-known contributors to a substrate’s overall osteogenic potential, and therefore the substrate's overall success. Unfortunately, it is still unknown how these substrate surface characteristics are transduced into intracellular signals by cells, preventing specific tailoring of …
Imaging Potential In Saturation Recovery Methods For Sarcoidosis Patients With Medical Devices, Samantha Zhao
Imaging Potential In Saturation Recovery Methods For Sarcoidosis Patients With Medical Devices, Samantha Zhao
Theses and Dissertations
Cardiovascular magnetic resonance (CMR) imaging is a preferred imaging methodology due to its lack of ionizing radiation and ability to detect myocardial inflammation and fibrosis using quantitative T1 mapping techniques. Cardiac sarcoidosis (CS) is characterized as the formation of granulomas in the myocardium. Current methods for detection include measuring non-cardiac specific C-reactive protein (CRP) levels, or PET imaging, which uses ionizing radiation, therefore CMR would make an ideal imaging option. However, many CS patients have implanted cardiac devices which can cause degradation in image. The modified Look-Locker inversion recovery (MOLLI) method is widely used in quantitative T1 mapping with high …
Evaluating Neuromuscular Function Of The Biceps Brachii After Spinal Cord Injury: Assessment Of Voluntary Activation And Motor Evoked Potential Input-Output Curves Using Transcranial Magnetic Stimulation, Thibault Roumengous
Theses and Dissertations
Activation of upper limb muscles is important for independent living after cervical spinal cord injury (SCI) that results in tetraplegia. An emerging, non-invasive approach to address post-SCI muscle weakness is modulation of the nervous system. A long-term goal is to develop neuromodulation techniques to reinnervate (i.e. resupply nerve to) muscle fiber and thereby increase muscle function in individuals with tetraplegia. Towards this goal, developing monitoring techniques to quantify neuromuscular function is needed to better direct neurorehabilitation. Assessment of voluntary activation (VA) is a promising approach because the location of the stimulus can be applied cortically using transcranial magnetic stimulation (TMS) …
Improving Patient-Specific Assessments Of Regional Aortic Mechanics Via Quantitative Magnetic Resonance Imaging With Early Applications In Patients At Elevated Risk For Thoracic Aortopathy, Patrick A. Jones
Theses and Dissertations
Unstable aortic aneurysms and dissections are serious cardiovascular conditions associated with high mortality. The current gold standards for assessment of stability, however, rely on simple geometric measurements, like cross-sectional area or increased diameter between follow-up scans, and fail to incorporate information about underlying aortic mechanics. Displacement encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI) has been used previously to determine heterogeneous circumferential strain patterns in the aortas of healthy volunteers. Here, I introduce technical improvements to DENSE aortic analysis and early pilot application in patients at higher risk for the development of aortopathies. Modifications to the DENSE aortic postprocessing …
Rheological Analysis Of The Mechanical Properties Of Murine Lungs Over The Lifespan, Olajumoke Olufunke Harrison
Rheological Analysis Of The Mechanical Properties Of Murine Lungs Over The Lifespan, Olajumoke Olufunke Harrison
Theses and Dissertations
To study the effects of aging in murine lungs, we characterized C57Bl6j mice from neonatal to 24-month-old mice. Samples were divided into two groups: Young Mice (YM) and Middle Age/Old Age Mice (MOM). The YM group included the neonatal and 6-10week. The MOM group included 7- and 22–24-month-old mice. Rheological testing was performed using a TA Instruments DHR-2 Rheometer to collect the mechanics of each mice sample. Utilizing a 20-mm parallel plate fixture, a gap of 0.8-1.0-mm, and a temperature setting of 25C, we conducted a frequency sweep. Samples were the decellularized over a four-day process then lyophilized for mass …
Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence
Nebulizer-Based Systems To Improve Pharmaceutical Aerosol Delivery To The Lungs, Benjamin M. Spence
Theses and Dissertations
Combining vibrating mesh nebulizers with additional new technologies leads to substantial improvements in pharmaceutical aerosol delivery to the lungs across therapeutic administration methods. In this dissertation, streamlined components, aerosol administration synchronization, and/or Excipient Enhanced Growth (EEG) technologies were utilized to develop and test several novel devices and aerosol delivery systems. The first focus of this work was to improve the poor delivery efficiency, e.g., 3.6% of nominal dose (Dugernier et al. 2017), of aerosolized medication administration to adult human subjects concurrent with high flow nasal cannula (HFNC) therapy, a form of continuous-flow non-invasive ventilation (NIV). The developed Low-Volume Mixer-Heater (LVMH) …