Heat Transfer Correlations For Low Approach Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn Jan 2009

Heat Transfer Correlations For Low Approach Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn

Articles

The experimental performance of an open industrial scale cooling tower, utilising small approach temperature differences (1–3 K), for rejection of heat at the low water temperatures (11–20 °C) typical of chilled ceilings and other sensible air–water heat dissipation systems in buildings, is examined. The study was carried out under temperate maritime climatic conditions (3–18 °C wet-bulb temperature range). Initially a theoretical analysis of the process at typical conditions for this climate was conducted, which indicated that a water to air (L/G) mass flow rate ratio of less than 1.0 was required for effective operation. Consequently for these low L/G ratios, …


Thermal Effectiveness Characteristics Of Low Approach Indirect Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn Jan 2007

Thermal Effectiveness Characteristics Of Low Approach Indirect Evaporative Cooling Systems In Buildings, Ben Costelloe, Donal Finn

Articles

Meteorological enthalpy analysis of temperate and maritime climates above latitude 45°N suggests that the water-side evaporative cooling technique has considerable unrealised potential with contemporary “high temperature” building cooling systems—such as chilled ceilings and displacement ventilation. As low approach conditions are the key to exploiting the cooling potential of the ambient air, thermal performance at such conditions needs to be investigated. To address the research issues, an industrial scale test rig, based on a low approach open cooling tower and plate heat exchanger and designed to maximise evaporative cooling potential, has been constructed. The thermal effectiveness of such systems (as a …


Experimental Energy Performance Of Open Cooling Towers Used Under Low And Variable Approach Conditions For Indirect Evaporative Cooling Of Buildings, Ben Costelloe, Donal Finn Jan 2003

Experimental Energy Performance Of Open Cooling Towers Used Under Low And Variable Approach Conditions For Indirect Evaporative Cooling Of Buildings, Ben Costelloe, Donal Finn

Articles

The success of chilled ceilings and displacement ventilation systems as a means of sensible cooling in buildings has prompted a review of evaporative cooling technology as an effective means of generating the required cooling water. When such cooling water is generated at low approach conditions (2–5 K), at the higher temperatures required in these systems (14–18°C), very high levels of availability result. In many north western European locations the levels of availability are such that the prospect of supplanting rather than simply supplementing the refrigeration system, for sensible cooling purposes, arises. The viability of the technique, however, largely depends on …