Articles 1 - 3 of 3
Full-Text Articles in Architecture
Optimization Of Advanced Building Integrated Photovoltaic And Thermal System With Dual Working Fluid, Barilelo E. Nghana
Optimization Of Advanced Building Integrated Photovoltaic And Thermal System With Dual Working Fluid, Barilelo E. Nghana
Electronic Thesis and Dissertation Repository
A direct exchange building integrated photovoltaic and thermal (BIPV/T) heat pump system is proposed where the heat extracted from the BIPV is used to drive the heat pump. To ensure a more stable diurnal system performance, especially at low solar conditions, air flow is instituted in the cavity between BIPV façade and the insulated inner wall. The airflow is directed from the heated or cooled space into the air channel and can be exhausted or returned to the space depending on the building operating conditions. The flow and geometrical parameters of the BIPV/T façade are optimized such that more than …
Coordinated Autonomic Managers For Energy Efficient Date Centers, Forough Norouzi
Coordinated Autonomic Managers For Energy Efficient Date Centers, Forough Norouzi
Electronic Thesis and Dissertation Repository
The complexity of today’s data centers has led researchers to investigate ways in which autonomic methods can be used for data center management. Autonomic managers try to monitor and manage resources to ensure that the components they manage are self-configuring, self-optimizing, self-healing and self-protecting (so called “self-*” properties). In this research, we consider autonomic management systems for data centers with a particular focus on making data centers more energy-aware. In particular, we consider a policy based, multi-manager autonomic management systems for energy aware data centers. Our focus is on defining the foundations – the core concepts, entities, relationships and algorithms …
Wind-Induced Pressures In Air Permeable, Double-Layer Roof Systems In Regions Of Separated Flow, Jeong Hee Oh
Wind-Induced Pressures In Air Permeable, Double-Layer Roof Systems In Regions Of Separated Flow, Jeong Hee Oh
Electronic Thesis and Dissertation Repository
This thesis is concerned with the wind-induced pressure distribution acting on air permeable, double-layer roof systems placed on low-rise buildings. Because of the pressure transmission into the cavity between layers, the pressure difference in the double-layer systems differs significantly from that in a single layer. The interior pressures (in the cavity between layers) are highly correlated with external pressures at the openings on the external surface of the outer layer and thereby, the net wind load for the design of the outer layer is considerably reduced by the pressure equalization between the external and internal surfaces of the outer layer. …