Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences

Electronic Thesis and Dissertation Repository

Biomechanics

Publication Year

Articles 1 - 4 of 4

Full-Text Articles in Entire DC Network

In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly Jan 2021

In Vitro Analyses Of The Contributions Of The Hip Capsule To Joint Biomechanics, Emma Donnelly

Electronic Thesis and Dissertation Repository

Optimal management of the hip capsule during arthroscopic surgery has not been established. The impact of incisions made to the capsule during minimally invasive procedures on joint biomechanics, and whether repair provides any benefit, continue to be debated. The effectiveness of capsular repair to restore native kinematics may be insufficient. Therefore, a better understanding of joint behavior during various capsule conditions is needed. A new robotic system was used to analyze the effect of progressive capsulotomy incision and repairs on the behavior of a normal hip within range of motion (ROM) limits with respect to the intact joint. Complete repairs …


Design, Development, Manufacturing And Biomechanical Testing Of Stand-Alone Cage For Posterior Lumbar Interbody Fusion, Fahad Alhelal Jun 2018

Design, Development, Manufacturing And Biomechanical Testing Of Stand-Alone Cage For Posterior Lumbar Interbody Fusion, Fahad Alhelal

Electronic Thesis and Dissertation Repository

Introduction: The most common method of spinal fusion includes pedicle screws instrumentation, either with or without interbody cage fusion. This thesis aimed to develop and test a novel stand-alone intervertebral device that eliminates the need for pedicle screws and rods.

Method: The stand-alone cage was designed in collaboration with spinal surgeons and engineers using computer assisting drawings, and manufactured in titanium by 3D printing. Biomechanical testing comparing the stand-alone cage with standard posterior lumbar interbody fusion (PLIF) in sawbones (n=6) and cadavers (n=8).

Result: Compared to PLIF, the stand-alone cage demonstrated no significant difference in range of flexion, lateral bend …


The Development Of A Temporomandibular Force Simulator To Study Craniofacial Strain In-Vitro, Kenneth Kc Ip Jun 2018

The Development Of A Temporomandibular Force Simulator To Study Craniofacial Strain In-Vitro, Kenneth Kc Ip

Electronic Thesis and Dissertation Repository

An in-vitro musculoskeletal loading simulator was developed to replicate the internal forces of mastication, and then employed in a comparison of clinically relevant facial fracture repairs. Muscle forces are simulated by pneumatic pistons via 3D printed mounts that are reverse-engineered from CT scan to match muscle attachment sites, which are adhered to bone in order to simulate native stress distributions. Bite force and bone strain pattern of the craniofacial structure under load were measured using a force sensor and strain gauges respectively. In a series of five fresh-frozen cadaveric heads, it was found that strain patterns of the craniofacial structure …


The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari Sep 2014

The Effect Of Fixation Plate Length On Spinal Instability Following Anterior Cervical Plate Fixation For The Repair Of In Vitro Flexion-Distraction Injuries, Abdulaziz J. Al-Kuwari

Electronic Thesis and Dissertation Repository

Abstract:

The Effect of Fixation Plate Length on Spinal Instability Following Anterior Cervical Plate Fixation for the Repair of in Vitro Flexion-Distraction Injuries

Introduction: Anterior cervical decompression and fusion with a plate (ACDFP) is a commonly performed treatment following a traumatic injury to the subaxial cervical spine. The purpose of the presented work was to determine the biomechanical effect of plate length on cervical spine kinematic stability following ACDFP stabilization for a simulated traumatic injury.

Methods: Eleven fresh-frozen cadaveric C5-C6 and C6-C7 motion segments were examined in this study. To assess kinematics, flexibility testing was performed on each specimen …