Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Entire DC Network

1,8,14,20-Tetraoxa-11,23-Dithiatricyclo[21.3.0.09,13]Hexacosa-9,12,21,24-Tetraene, Pawel Wagner, Maciej Kubicki, Mieczyslaw Lapkowski Jan 2006

1,8,14,20-Tetraoxa-11,23-Dithiatricyclo[21.3.0.09,13]Hexacosa-9,12,21,24-Tetraene, Pawel Wagner, Maciej Kubicki, Mieczyslaw Lapkowski

Australian Institute for Innovative Materials - Papers

Crystals of the title compd. are orthorhombic, space group Pbca; Z = 4. Mols. lie on crystallog. centers of inversion, but have approx. C2h mol. symmetry. The parallel thiophene rings are almost exactly planar; the overall conformation of the mol. is chair-like. The mols. have voids that could, in principle, accommodate small guest mols., although in the crystal structure access to these voids is blocked by neighboring mols.


A Flip-Disorder In The Structure Of 3-[2-(Anthracen-9-Yl)Ethenyl]Thiophene, Pawel Wagner, David L. Officer, Maciej Kubicki Jan 2006

A Flip-Disorder In The Structure Of 3-[2-(Anthracen-9-Yl)Ethenyl]Thiophene, Pawel Wagner, David L. Officer, Maciej Kubicki

Australian Institute for Innovative Materials - Papers

In the crystal structure of the title compound, C20H14S, the thio­phene rings are disordered; such a flip-type disorder is typical for simple, monosubstituted thio­phene derivatives. Two planar fragments, the thio­phene and the anthracene units, are almost perpendicular in order to relieve the H⋯H steric strains. The crystal packing is determined by van der Waals inter­actions, π–π stacking between the anthracene fragments, and some weak C—H⋯S and C—H⋯π short directional contacts.


3-Methyl-5-Nitrouracil, Maciej Kubicki, Pawel Wagner Jan 2006

3-Methyl-5-Nitrouracil, Maciej Kubicki, Pawel Wagner

Australian Institute for Innovative Materials - Papers

The mol­ecules of the title compound, C5H5N3O4, are approximately planar. The nitro group makes a dihedral angle of 1.3 (4)° with the plane of the six-membered ring. This coplanar disposition is a reason for the changes in valence angles in the vicinity of the nitro group. Mol­ecules are connected into dimers by means of N—H⋯O hydrogen bonds, and these dimers make larger structures with the help of relatively short C—H⋯O hydrogen bonds.


Electrochemical Study Of 1,3-Indandione Derivatives Of Terthiophenes, Mieczyslaw Lapkowski, Sylwia Plewa, Pawel Wagner, David L. Officer Jan 2006

Electrochemical Study Of 1,3-Indandione Derivatives Of Terthiophenes, Mieczyslaw Lapkowski, Sylwia Plewa, Pawel Wagner, David L. Officer

Australian Institute for Innovative Materials - Papers

Properties and behavior of a group of four newly synthesized derivatives of terthiophene and terthienylenvinylene was studied. All four investigated monomers bear a 1,3-indandione substituent at the central thiophene ring and two of them (ThIV, ThIVM) have additional vinyl bonds introduced between the thiophene rings. In addition, ThIM and ThIVM have 5 positions of the two terminal rings blocked with methyl groups. The measurements were done using cyclic voltamperometry (CV) in solutions of 0.1M Bu4NBF4 in CH2Cl2. It was found that ThI and ThIV polymerise easily. CV of ThI reveals a reduction peak …


Experience In The Application Of Iec/Tr 61000-3-6 To Harmonic Allocation In Transmission Systems, T J. Browne, V J. Gosbell, S Perera, D A. Robinson, L M. Falla, P J. Windle, A C. D Perera Jan 2006

Experience In The Application Of Iec/Tr 61000-3-6 To Harmonic Allocation In Transmission Systems, T J. Browne, V J. Gosbell, S Perera, D A. Robinson, L M. Falla, P J. Windle, A C. D Perera

Faculty of Engineering and Information Sciences - Papers: Part A

Technical report IEC/TR 61000-3-6 is widely used as a guide to harmonic management in HV and MV networks, assisting in coordination of harmonic levels between utility and customer. In 2001, Australia and New Zealand adopted the harmonic standard AS/NZS 61000.3.6, which closely follows the above IEC technical report. As a result, transmission utilities and connected loads are required by government regulations to abide by the harmonic allocations set by the standard. The technical report contains some useful general principles which can be applied to the harmonic management of power systems. However, unexpected difficulties can be found when attempts are made …