Comparative Simulations Of An Electrochromic Glazing And A Roller Blind As Controlled By Seven Different Algorithms, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O'Sullivan Dec 2023

Comparative Simulations Of An Electrochromic Glazing And A Roller Blind As Controlled By Seven Different Algorithms, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O'Sullivan

Articles

The use of roller blind as a surrogate for a switchable glazing in a dynamic building environmental simulation is investigated. Seven different control algorithms were applied to simulations of both operations of the blind and of the switchable glazing. The configurations compared were an electrochromic glazing and a roller blind, the controllers used were rule-based, proportional-integral-derivative (PID), anti-windup PID (aPID) and a model predictive controller (MPC). Particular case studies were examined in the weather conditions of Dublin, Ireland to make comparisons of simulated energy savings and occupancy daylight comfort from the use of electrochromic glazing or a roller blind with …


Optimal Temperature-Actuated Control Of A Thermally-Insulated Roller Blind, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O'Sullivan Oct 2023

Optimal Temperature-Actuated Control Of A Thermally-Insulated Roller Blind, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dominic O'Sullivan

Articles

By altering the thermal equilibria between internal and ambient environments, dynamic insulation can minimize heating and cooling building energy requirements. The performance of a thermally-insulated roller blind was evaluated both experimentally and via simulation studies. The variation of blind position was optimized to minimize building energy consumption, maintain thermal comfort, and minimize daylight discomfort for a particular system, location and conditions. The roller blind was adjusted between four positions, from fully-open to fully-closed, optimal indoor temperature switching thresholds found for moving to these blind positions were 15 °C, 18.4 °C, 19.4 °C and 21.4 °C, respectively. Using these resulted in …


Comparative Simulations Of An Electrochromic Glazing And A Roller Blind As Controlled By Seven Different Algorithms, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dympna O'Sullivan Jan 2023

Comparative Simulations Of An Electrochromic Glazing And A Roller Blind As Controlled By Seven Different Algorithms, Hani Alkhatib, Philippe Lemarchand, Brian Norton, Dympna O'Sullivan

Articles

The use of roller blind as a surrogate for a switchable glazing in a dynamic building environmental simulation is investigated. Seven different control algorithms were applied to simulations of both operations of the blind and of the switchable glazing. The configurations compared were an electrochromic glazing and a roller blind, the controllers used were rule-based, proportional-integral-derivative (PID), anti-windup PID (a PID) and a model predictive controller (MPC). Particular case studies were examined in the weather conditions of Dublin, Ireland to make comparisons of simulated energy savings and occupancy daylight comfort from the use of electrochromic glazing or a roller blind …