Full-Text Articles in Entire DC Network

Energy Storage System For Reduction Of Mid-Line Voltage Variation Of A Dfig Wnd Turbine Connected To A Weak Grid, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich Jan 2006

Energy Storage System For Reduction Of Mid-Line Voltage Variation Of A Dfig Wnd Turbine Connected To A Weak Grid, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich

Faculty of Engineering and Information Sciences - Papers: Part A

Penetration of wind power into electricity system is constantly increasing. Wind resources are usually distant from existing transmission lines. Wind farms are often connected to weak grids far from central generation stations. Maximum wind power extraction causes the more irregular and unpredicted power output of wind turbine, which has same nature as wind speed variation. The voltage in such long line is vulnerable with the consumption and generation imbalance. In a long line, the mid-line voltage is largely affected by the variation and the penetration of the wind fluctuating power. Fluctuating nature of wind power output and long transmission line …


Control Stabilisation Of An Islanded System With Dfig Wind Turbine, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich Jan 2006

Control Stabilisation Of An Islanded System With Dfig Wind Turbine, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich

Faculty of Engineering and Information Sciences - Papers: Part A

Distributed Generation (DG) is often used to export power to the utility system. Loss of main supply can cause a severe loading mismatch between DG generation and load consumption. Consequently, the voltage and frequency of the islanded system will cross the allowable limit. Due to this fact, it is essential to control the voltage and frequency in the islanding mode of operation. In this paper, control stabilisation of an islanded system with a doubly-fed induction generator (DFIG) wind turbine has been addressed. Wind DG produces variable output and is not capable to produce enough reactive power. Hence, it is imperative …


Black Start With Dfig Based Distributed Generation After Major Emergencies, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich Jan 2006

Black Start With Dfig Based Distributed Generation After Major Emergencies, M Aktarujjaman, Kashem M. Muttaqi, Michael Negnevitsky, Gerard Ledwich

Faculty of Engineering and Information Sciences - Papers: Part A

Grid connected distributed generation (DG) increases reliability and additional benefits for consumers as well as utilities. The stable and reliable operation of a power system is necessary after major emergencies (or blackouts) following a major system event. Distributed generation may be capable of black start and contribute to fast restoration process at medium to low voltage level. A large scale voltage and frequency excursions may occur during the process of black start with distributed generation due to low inertia and intermittency in power generation. Energy storage integrated with DG can absorb initial impact of central generation and ensure smooth load …