Balanced Return Air, Duct Airtightness, And Combustion/Dilution Air Code Compliance In 40 Central Florida Homes, Florida Solar Energy Center, James Cummings
Balanced Return Air, Duct Airtightness, And Combustion/Dilution Air Code Compliance In 40 Central Florida Homes, Florida Solar Energy Center, James Cummings
FSEC Energy Research Center®
This report has been extracted from a larger report titled "Florida Building Code - Enhance Florida's Building to Next-Generation Energy & Mechanical Codes and Enrich Compliance", FSEC-CR-1678-06, November 29, 2006, which can be found at http://www.fsec.ucf.edu/en/publications/pdf/FSEC-CR-1678-06.pdf
Energy Efficient Renovations Of Storm Damaged Residences - Florida Case Studies, Florida Solar Energy Center, Neil Moyer
Energy Efficient Renovations Of Storm Damaged Residences - Florida Case Studies, Florida Solar Energy Center, Neil Moyer
FSEC Energy Research Center®
Storm-damaged homes offer the opportunity for repairs that reduce energy use, improve comfort and enhance resistance to future storms. Case studies of four Florida homes damaged in the summer of 2004 were documented to show the costs and benefits of various retrofit strategies. All four homes required roof replacement and each took advantage of roof cladding with higher reflectance than the original, a proven means of reducing cooling energy use. Two of the case studies included improvements to attic insulation, tightening of the envelope and/or duct system and improved efficiency equipment and lighting. Energy savings attributable to storm repairs were …
Unbalanced Return Air In Commercial Buildings, Florida Solar Energy Center, Charles Withers, Jr.
Unbalanced Return Air In Commercial Buildings, Florida Solar Energy Center, Charles Withers, Jr.
FSEC Energy Research Center®
Research in 88 central Florida commercial buildings during the last decade has found that 26% of the air distribution systems had substantially unbalanced return air. Unbalanced return air occurs when there is a restriction to air flow between the supply discharge and the return air, creating positive and negative pressure fields throughout the building. Severe consequences in commercial buildings can occur as a result of unbalanced air flows. This paper examines unbalanced return air and its consequences in three commercial buildings, and explains why balancing air flow in buildings is a critical part of maintaining a healthy and energy efficient …
Unbalanced Return Air In Residences: Causes, Consequences, And Solutions, Florida Solar Energy Center, James Cummings
Unbalanced Return Air In Residences: Causes, Consequences, And Solutions, Florida Solar Energy Center, James Cummings
FSEC Energy Research Center®
Field research performed in 70 central Florida homes found that return grills are almost always located in the central zone of the house, and that individual rooms rarely have ducted return air or return transfer pathways. When interior doors were closed, the closed rooms went to +0.0249 inches of water gauge (in w.g.) (+6.2 pascals (Pa)) wrt outdoors (wrt = with respect to), and the central zone went to -0.0116 in w.g. (-2.9 Pa) wrt outdoors. Room pressures as high as +0.150 in w.g. (+37.3 Pa) and central zone pressure as low as -0.059 in w.g. (-14.7 Pa) wrt outdoors …