Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

PDF

Iowa State University

1997

Bioresource and Agricultural Engineering

Matthew J. Helmers

Articles 1 - 1 of 1

Full-Text Articles in Entire DC Network

Use Of Ultimate Load Theories For Design Of Drilled Shaft Sound Wall Foundations, Matthew J. Helmers Jun 1997

Use Of Ultimate Load Theories For Design Of Drilled Shaft Sound Wall Foundations, Matthew J. Helmers

Matthew J. Helmers

A study was performed to investigate the factors that affect the accuracy of the procedures used by the Virginia Department of Transportation for design of drilled shaft sound wall foundations. Field load tests were performed on eight inch and nine inch diameter drilled shafts, and the results were compared to theoretical solutions for ultimate lateral load capacity. Standard Penetration Tests were run in the field and laboratory strength tests were performed on the soils from the test sites. It was found that published correlations between blow count and friction angle for sands and gravels can be used to estimate friction …