A New Microfluidic Device For Complete, Continuous Separation Of Microparticles, Liang-Liang Fan, Xu-Kun He, Yu Han, Li Du, Liang Zhao, Jiang Zhe Apr 2015

A New Microfluidic Device For Complete, Continuous Separation Of Microparticles, Liang-Liang Fan, Xu-Kun He, Yu Han, Li Du, Liang Zhao, Jiang Zhe

Dr. Jiang Zhe

A microchannel with symmetric sharp corners is reported for particle separation, based on the inter-play between the inertial lift force and the centrifugal force induced by sharp corners. At an appropriate flow rate, the centrifugal force is larger than the inertial lift force on large particles, while the inertial lift force is dominant on small particles. Hence large particles are centrifuged to the center, while small par-ticles are focused at side streams, achieving complete particle separation. The device requires no sheath flow, avoiding the dilution of analyte sample and complex operation, and can be potentially used for many lab-on-a-chip applications.


Novel Quantitative Macro Biomolecule Analysis Based On A Micro Coulter Counter, Y Han, H. Wu, F. Liu, Gang Cheng, Jiang Zhe Apr 2015

Novel Quantitative Macro Biomolecule Analysis Based On A Micro Coulter Counter, Y Han, H. Wu, F. Liu, Gang Cheng, Jiang Zhe

Dr. Jiang Zhe

We demonstrate quantitative biomolecule analysis using a micro coulter counter. Specific binding between antibody functionalized microparticles and target biomolecule cause large aggregates of microparticles. The micro coulter counter was employed to measure aggregation ratio, ratio of the aggregate counts to the total particle counts. Goat anti-rabbit IgG, used as a model biomarker, were tested in this paper. The experiment results showed that the aggregation ratio increases with the increasing biomolecule concentration, and the detectable concentration range from 16 to 160 ng/ml was achieved.


Static And Dynamic Responsive Behavior Of Polyelectrolyte Brushes Under External Electrical Field, Hui Ouyang, Zhenhai Xia, Jiang Zhe Apr 2015

Static And Dynamic Responsive Behavior Of Polyelectrolyte Brushes Under External Electrical Field, Hui Ouyang, Zhenhai Xia, Jiang Zhe

Dr. Jiang Zhe

The static and dynamic behaviors of partially charged and end-grafted polyelectrolyte brushes in response to electric fields were investigated by means of molecular dynamics simulation. The results show that the polymer brushes can be partially or fully stretched by applying an external electric field. Moreover, the brushes can switch reversibly from collapsed to stretched states, fully responding to the AC electric stimuli, and the gating response frequency can reach a few hundred MHz. The effects of the grafting density, the charge fraction of the brushes and the strength of the electric field on the average height of the polymer brushes …


High School Bridge Program: A Multidisciplinary Stem Research Program, Jiang Zhe, Dennis Doverspike, Julie Zhao, Paul C. Lam, Craig C. Menzemer Apr 2015

High School Bridge Program: A Multidisciplinary Stem Research Program, Jiang Zhe, Dennis Doverspike, Julie Zhao, Paul C. Lam, Craig C. Menzemer

Dr. Jiang Zhe

A Science, Technology, Engineering and Math (STEM) summer Bridge Program was developed for high school students. The program was designed to encourage students to consider choosing an engineering major in college and to explore STEM as a future career. This was accomplished through a 10-week program involving multidisciplinary research activities. The participants in the program included 33 high school students. Among former participants in position to make a choice in terms of attending college, 100% had chosen to continue on in college, and 86% had chosen to major in a STEM area. The results indicated that that the program had …


An Evaluation Of A Stem Program For Middle School Students On Learning Disability Related Ieps, Paul C. Lam, Dennis Doverspike, Julie Zhao, Jiang Zhe, Craig C. Menzemer Apr 2015

An Evaluation Of A Stem Program For Middle School Students On Learning Disability Related Ieps, Paul C. Lam, Dennis Doverspike, Julie Zhao, Jiang Zhe, Craig C. Menzemer

Dr. Jiang Zhe

A year long Science, Technology, Engineering and Math (STEM) program was developed for middle schools students on Individualized Education Programs (IEPs) involving learning disabilities. The workshops were designed to encourage students both on IEPs and not on IEPs to explore STEM as a future career choice by building their knowledge and confidence. The participants in the workshops included 11 students on IEPs and 15 students not on IEPs. Parents also provided feedback regarding their attitudes toward the program. The results indicated that there were increases in student participant knowledge and career interest for both the students not on IEPs and …


Passive Continuous Particle Focusing In A Microchannel With Symmetric Sharp Corner Structures, Liang-Liang Fan, Liang Zhao, Xu-Kun He, Hand Yu, Qing-Yu Wei, Jiang Zhe Apr 2015

Passive Continuous Particle Focusing In A Microchannel With Symmetric Sharp Corner Structures, Liang-Liang Fan, Liang Zhao, Xu-Kun He, Hand Yu, Qing-Yu Wei, Jiang Zhe

Dr. Jiang Zhe

We report a continuous passive particle focusing method using a novel microchannel with symmetric sharp corners which induce curved streamlines and large centrifugal force on particles. At appropriate flow rate, the centrifugal force generated on particles exceeds the inertial lift force; particles driven by the centrifugal force migrate toward the center of the microchannel, achieving continuous particle focus-ing. With simple structure and operation, this method can be potentially used in particle focusing and ex-traction processes in a variety of lab-on-a chip applications.


A Versatile Microparticle-Based Immunoaggregation Assay For Macromolecular Biomarker Detection And Quantification, Haiyan Wu, Yu Han, George G. Chase, Qiong Tang, Chen-Jung Lee, Bin Cao, Jiang Zhe, Gang Cheng Apr 2015

A Versatile Microparticle-Based Immunoaggregation Assay For Macromolecular Biomarker Detection And Quantification, Haiyan Wu, Yu Han, George G. Chase, Qiong Tang, Chen-Jung Lee, Bin Cao, Jiang Zhe, Gang Cheng

Dr. Jiang Zhe

The rapid, sensitive and low-cost detection of macromolecular biomarkers is critical in clinical diagnostics, environmental monitoring, research, etc. Conventional assay methods usually require bulky, expensive and designated instruments and relative long assay time. For hospitals and laboratories that lack immediate access to analytical instruments, fast and low-cost assay methods for the detection of macromolecular biomarkers are urgently needed. In this work, we developed a versatile microparticle (MP)-based immunoaggregation method for the detection and quantification of macromolecular biomarkers. Antibodies (Abs) were firstly conjugated to MP through streptavidin-biotin interaction; the addition of macromolecular biomarkers caused the aggregation of Ab-MPs, which were subsequently …