Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Entire DC Network

Electron Transmission Through Micrometer Sized Funnelshaped Tapered Glass Capillaries And Electron Micro-Beam Production, Samanthi Jayamini Wickramarachchi Jun 2015

Electron Transmission Through Micrometer Sized Funnelshaped Tapered Glass Capillaries And Electron Micro-Beam Production, Samanthi Jayamini Wickramarachchi

Dissertations

The prime motivation of this work is to understand the fundamental transmission process of an electron beam through a funnel-shaped capillary taking into account its shape together with the energy, angular and time dependence of the transmitted electrons produce a microsized electron beam. The utilized capillaries had inlet/outlet diameters of 800/16 μm, 800/100 μm and lengths of 35 mm. Considerable transmission of 800 and 1000 eV electrons for tilt angles up to 1.5o and only small transmission for 500 eV electrons was observed for the capillary with the smaller outlet diameter of 16 μm. Incident electrons with energies of …


Dual-Spacecraft Reconstruction Of A Three-Dimensional Magnetic Flux Rope At The Earth's Magnetopause, H. Hasegawa, B. U. Ö. Sonnerup, S. Eriksson, T. K. M. Nakamura Feb 2015

Dual-Spacecraft Reconstruction Of A Three-Dimensional Magnetic Flux Rope At The Earth's Magnetopause, H. Hasegawa, B. U. Ö. Sonnerup, S. Eriksson, T. K. M. Nakamura

Dartmouth Scholarship

We present the first results of a data analysis method, developed by Sonnerup and Hasegawa (2011), for reconstructing three-dimensional (3-D), magnetohydrostatic structures from data taken as two closely spaced satellites traverse the structures. The method is applied to a magnetic flux transfer event (FTE), which was encountered on 27 June 2007 by at least three (TH-C, TH-D, and TH-E) of the five THEMIS probes near the subsolar magnetopause. The FTE was sandwiched between two oppositely directed reconnection jets under a southward interplanetary magnetic field condition, consistent with its generation by multiple X-line reconnection. The recovered 3-D field indicates that a …


Towards A Resolution Of The Proton Form Factor Problem: New Electron And Positron Scattering Data, Clas Collaboration, D. Adikaram, L. B. Weinstein, R. P. Bennett, K. P, Adhikari, M. J. Amaryan, S. Careccia, L. El Fassi, C. E. Hyde, A. Klein, S E. Kuhn, M. Mayer, Z. W. Zhao Jan 2015

Towards A Resolution Of The Proton Form Factor Problem: New Electron And Positron Scattering Data, Clas Collaboration, D. Adikaram, L. B. Weinstein, R. P. Bennett, K. P, Adhikari, M. J. Amaryan, S. Careccia, L. El Fassi, C. E. Hyde, A. Klein, S E. Kuhn, M. Mayer, Z. W. Zhao

Physics Faculty Publications

There is a significant discrepancy between the values of the proton electric form factor, GpE, extracted using unpolarized and polarized electron scattering. Calculations predict that small two-photon exchange (TPE) contributions can significantly affect the extraction of GpEfrom the unpolarized electron-proton cross sections. We determined the TPE contribution by measuring the ratio of positron-proton to electron-proton elastic scattering cross sections using a simultaneous, tertiary electron-positron beam incident on a liquid hydrogen target and detecting the scattered particles in the Jefferson Lab CLAS detector. This novel technique allowed us to cover a wide range in virtual …