Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Entire DC Network

Implementation Of An Anthropomorphic Phantom For The Evaluation Of Proton Therapy Treatment Procedures, Ryan L. Grant May 2010

Implementation Of An Anthropomorphic Phantom For The Evaluation Of Proton Therapy Treatment Procedures, Ryan L. Grant

Dissertations & Theses (Open Access)

With an increasing number of institutions offering proton therapy, the number of multi-institutional clinical trials involving proton therapy will also increase in the coming years. The Radiological Physics Center monitors sites involved in clinical trials through the use of site visits and remote auditing with thermoluminescent dosimeters (TLD) and mailable anthropomorphic phantoms. Currently, there are no heterogeneous phantoms that have been commissioned to evaluate proton therapy. It was hypothesized that an anthropomorphic pelvis phantom can be designed to audit treatment procedures (patient simulation, treatment planning and treatment delivery) at proton facilities to confirm agreement between the measured dose and calculated …


Dosimetric Effects Near Implanted Vascular Access Ports Under External Electron Beam Radiation, David Coll Segarra Jan 2010

Dosimetric Effects Near Implanted Vascular Access Ports Under External Electron Beam Radiation, David Coll Segarra

Browse all Theses and Dissertations

Previous studies on dosimetry show important effects for metal vascular access ports for x-rays and electron beams and moderate to no effects for plastic ports for x-ray beams when ports are in the path of the beam. No previous studies exist regarding the effects of electron beams on vascular access ports other than for those made of metal although it has been suggested that electron beam attenuation through non-metal ports may be possible.

Measurements of relative ionization through the device and adjacent to the device anteriorly and laterally were taken. A clinical particle accelerator delivered typical clinical electron beams of …