Modern Techniques Used To Improve A Hearing Conservation Program In A Power Generating Plant, Eilyn Fabregas
Modern Techniques Used To Improve A Hearing Conservation Program In A Power Generating Plant, Eilyn Fabregas
Theses
A noise survey was conducted on the pump floor of a power generating plant, which included measuring noise levels at 261 areas of the floor (6,000 square feet) and the employees' noise doses, or 8-hour time-weighted average (TWAs). The noise levels of the 261 areas were recorded using a Sound Level Meter, and the noise doses (i.e., TWAs) were measured using a noise Dosimeter. It was found that both noise levels and TWAs were higher than the OSHA's permissible exposure limit (PEL) of 90 dBA and the action level of 85 dBA. According to the data gathered, it was determined …