The Equi-Biaxial Fatigue Characteristics Of Epdm Under True (Cauchy) Stress Control Conditions, Mark Johnson, Ray Ekins, Niall Murphy, Stephen Jerrams, John Hanley Jun 2013

The Equi-Biaxial Fatigue Characteristics Of Epdm Under True (Cauchy) Stress Control Conditions, Mark Johnson, Ray Ekins, Niall Murphy, Stephen Jerrams, John Hanley

Conference Papers

ABSTRACT: Strain amplitude control is most often employed when carrying out fatigue testing of rubber components. Often the design engineer requires fatigue test data that is based on load amplitude control. This is analogous to engineering or nominal stress amplitude control. This usually makes it easy to maintain the load within the specified test limits during extended testing. Values of true stress and strain can be obtained from this approach, but the magnitudes of the maximum true stresses in these tests increase with accumulated cycles, whereas the equivalent maximum engineering stress values remain constant. This is easily demonstrated in the …


The Equi-Biaxial Fatigue Characteristics Of Epdm Under True (Cauchy) Stress Control Conditions, Mark Johnson Jun 2013

The Equi-Biaxial Fatigue Characteristics Of Epdm Under True (Cauchy) Stress Control Conditions, Mark Johnson

Conference Papers

Strain amplitude control is most often employed when carrying out fatigue testing of rubber components. Often the design engineer requires fatigue test data that is based on load amplitude control. This is analogous to engineering or nominal stress amplitude control. This usually makes it easy to maintain the load within the specified test limits during extended testing. Values of true stress and strain can be obtained from this approach, but the magnitudes of the maximum true stresses in these tests increase with accumulated cycles, whereas the equivalent maximum engineering stress values remain constant. This is easily demonstrated in the uniaxial …


The Effect Of Microstructure On The Dynamic Equi-Biaxial Fatigue Behaviour Of Magnetorheological Elastomers, Yanfen Zhou, Stephen Jerrams, Tony Betts, Lin Chen Jan 2013

The Effect Of Microstructure On The Dynamic Equi-Biaxial Fatigue Behaviour Of Magnetorheological Elastomers, Yanfen Zhou, Stephen Jerrams, Tony Betts, Lin Chen

Conference Papers

Dynamic equi-biaxial fatigue behaviour of isotropic and anisotropic magnetorheological elas-tomers (MREs) based on a silicone rubber matrix was investigated using the bubble inflation method. Con-stant engineering stress amplitude was used as the control mode and samples were fatigued over different stress ranges between 0.75MPa and 1.4MPa. S-N (Wöhler) curves showing plots of stress amplitude (σa) ver-sus cycles to failure (N) are presented. Stress-strain behaviour throughout the fatigue process is described. Elastic modulus (E*) was studied for the specific cycles measured. It was found that anisotropic MREs exhi-bited greater fatigue resistance than isotropic MREs for a given magnetic particle content. Stress …