Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Life Sciences

PDF

Iowa State University

2003

Cattle

Articles 1 - 3 of 3

Full-Text Articles in Entire DC Network

Assessment Of Moisture Control And Additives For Odor Reduction From Open-Lot Feedyard Surfaces, Jocelyn D. Buchanan, David B. Parker, Marty B. Rhoades, Jacek A. Koziel, William J. Rogers Jul 2003

Assessment Of Moisture Control And Additives For Odor Reduction From Open-Lot Feedyard Surfaces, Jocelyn D. Buchanan, David B. Parker, Marty B. Rhoades, Jacek A. Koziel, William J. Rogers

Jacek A. Koziel

Amendments for reducing odor from open-lot beef cattle feedyards were evaluated in the laboratory. Manure was placed in small Tupperware® containers. Water and amendments were added to the manure surface and the containers were attached to a vacuum pump that continually passed 2.5 L/min of carbon-filtered air over the surface. Eleven different amendments were tested, at two different concentrations, in a series of five experiments. Odor samples were collected 3 times during a 10-day period in each experiment and were analyzed by trained panelists for detection threshold (DT), intensity and hedonic tone. None of the amendments showed any overwhelming evidence …


Odor Characterization At Open-Lot Beef Cattle Feedyards Using Triangular Forced Choice Olfactometry, David B. Parker, Marty B. Rhoades, Brent W. Auvermann, Jacek A. Koziel Jul 2003

Odor Characterization At Open-Lot Beef Cattle Feedyards Using Triangular Forced Choice Olfactometry, David B. Parker, Marty B. Rhoades, Brent W. Auvermann, Jacek A. Koziel

Jacek A. Koziel

Odor samples were collected two to four times per month over a one-year period in 2002-2003 at three large open-lot beef cattle feedyards in the Texas panhandle. Samples were collected in 10 L Tedlar bags using a vacuum chamber upwind of the feedyard, downwind of the pens, and downwind of the runoff storage pond. Samples were analyzed in the odor lab for detection threshold (DT) using triangular forced choice olfactometry with trained human odor panelists. Full-strength odor samples were also analyzed for intensity and hedonic tone. Weather data was collected on-site at each of the feedyards for correlation to odor …


Characterization Of Volatile Organic Compounds In Bovine Breath Using Solid-Phase Microextraction And Gas Chromatography-Mass Spectrometry, Jacek A. Koziel, Jarett P. Spinhirne, Norbert K. Chirase Jul 2003

Characterization Of Volatile Organic Compounds In Bovine Breath Using Solid-Phase Microextraction And Gas Chromatography-Mass Spectrometry, Jacek A. Koziel, Jarett P. Spinhirne, Norbert K. Chirase

Jacek A. Koziel

A face mask sampling device, DVB/Carboxen/PDMS 50/30 µ m solid phase microextraction (SPME) fibers, and a gas chromatograph with a mass spectrometer detector (GC-MS) were used for sampling and analysis of volatile organic compounds (VOCs) in bovine breath. Breath of 3 morbid steers with respiratory tract infections and 3 healthy steers were sampled 7 times in 19 days for 15 min at each sampling. A total of 21 VOCs were detected, many of them for the first time in cattle breath. Preliminary statistical analyses using Chi-square Test on the frequency of detection of each VOC in each group was performed. …