Full-Text Articles in Entire DC Network

Cooling Performance Assessment Of Building America Homes, Florida Solar Energy Center, David Chasar Jul 2006

Cooling Performance Assessment Of Building America Homes, Florida Solar Energy Center, David Chasar

FSEC Energy Research Center®

Long-term monitoring of building energy use and environmental conditions has been a strong component of FSEC research since the 1980s. Fully-automated data collection, verification, archiving and management ensure accurate logging of large amounts of data simultaneously from numerous field sites prior to being made available for analysis and display via the internet. Homes are typically monitored using 15 to 50 channels of data to measure indoor and outdoor environmental conditions and energy use of heating, cooling, water heating, whole house, and other points (e.g. Solar PV or Solar DHW) if needed.

Energy performance in many Building America homes has been …


Study Of Discharge Coefficient And Trends In Film Cooling Effectiveness Of Conical Holes With Increasing Diffusion Angles, Humberto Zuniga, Jan 2006

Study Of Discharge Coefficient And Trends In Film Cooling Effectiveness Of Conical Holes With Increasing Diffusion Angles, Humberto Zuniga,

Electronic Theses and Dissertations

Previous studies indicate that increasing the diffusion angle in conical film-cooling holes leads to an improvement in their film cooling effectiveness. Discharge coefficient and film cooling effectiveness measurements are conducted to characterize this behavior. Part of the focus of this investigation is to find out how this trend develops and attempt to ascertain the optimum cone angle, if possible. Six test plates, each with one row of eight conical-shaped cooling holes of equal diffusion angles of 0, 1, 2, 3, 6, or 8 [degrees], with respect to the hole axis are used in this study. The ratios of the hole …


Abstract/Conclusion: Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii Jan 2006

Abstract/Conclusion: Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii

FSEC Energy Research Center®

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions, especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may …


Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii Jan 2006

Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii

FSEC Energy Research Center®

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions - especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and …