Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Engineering

University of Central Florida

2006

Air Quality

Articles 1 - 3 of 3

Full-Text Articles in Entire DC Network

School Conditions Will Continue To Earn Failing Grades, Florida Solar Energy Center, Jeffrey Sonne Jul 2006

School Conditions Will Continue To Earn Failing Grades, Florida Solar Energy Center, Jeffrey Sonne

FSEC Energy Research Center®

This study addresses indoor air quality and general conditions problems in schools throughout the United States. Tools employed to investigate conditions include a nationwide, web-based survey, characterization of actual operating conditions in schools through field audits and diagnostic tests, and retrofits in problem schools.

Survey results found temperature to be by far the greatest comfort complaint in regular classrooms, with indoor air quality (IAQ) and then humidity being the next greatest areas of complaints. Ventilation problems were found at each of eight audited schools. These problems appear to be occurring due to a combination of factors including lack of maintenance, …


Abstract/Conclusion: Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii Jan 2006

Abstract/Conclusion: Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii

FSEC Energy Research Center®

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions, especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may …


Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii Jan 2006

Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii

FSEC Energy Research Center®

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions - especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and …