Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Engineering

PDF

Cleveland State University

Theses/Dissertations

Design

Publication Year

Articles 1 - 6 of 6

Full-Text Articles in Entire DC Network

A Reticulation Of Skin-Applied Strain Sensors For Motion Capture, Christopher A. Schroeck Jan 2019

A Reticulation Of Skin-Applied Strain Sensors For Motion Capture, Christopher A. Schroeck

ETD Archive

The purpose of this research is to develop a system of motion capture based on skin-applied strain sensors. These elastic sensors are of interest because they can be applied to the body without restricting motion and are well suited to operate in more practical environments, such as sports fields, gymnasiums, and outdoor areas. This combination is currently not available in the field of motion capture. The current issues with strain sensor motion capture technology is the accurate is not sufficient for motion analysis and axial rotation monitoring of joints is not available. This project will build and test a sensor …


Designing Novel Grooved Pallets For Industrial Application, Mirza Mohammed Abdullah Baig Jan 2018

Designing Novel Grooved Pallets For Industrial Application, Mirza Mohammed Abdullah Baig

ETD Archive

The purpose of this study was to model an improved pallet design which could overcome the drawbacks and failures of the pallets available in the market today. The new modeled pallets were designed to improve the capacity of the individual pallets and thereby increase the efficiency of the material handling process. The new modeled pallets were also designed with the aim to replace the racking system used for storage in the warehouse industry. The study was performed using two finite element analysis software, SOLIDWORKS and ANSYS, as analysis tools to study the behavior of the design under various real world …


Advanced Manufacturing Of Titanium Alloys For Biomedical Applications, Nicholas C. Mavros Jan 2018

Advanced Manufacturing Of Titanium Alloys For Biomedical Applications, Nicholas C. Mavros

ETD Archive

In metallurgy, Titanium has been a staple for biomedical purposes. Its low toxicity and alloying versatility make it an attractive choice for medical applications. However, studies have shown the difference in elastic modulus between Titanium alloys (116 GPa) and human bone (40-60 GPa) contribute to long term issues with loose hardware fixation. Additionally, long term studies have shown elements such as Vanadium and Aluminum, which are commonly used in Ti-6Al-4V biomedical alloys, have been linked to neurodegenerative diseases like Alzheimers and Parkinsons. Alternative metals known to be less toxic are being explored as replacements for alloying elements in Titanium alloys. …


Probabilistic Structural And Thermal Analysis Of A Gasketed Flange, Atul G. Tanawade Jan 2011

Probabilistic Structural And Thermal Analysis Of A Gasketed Flange, Atul G. Tanawade

ETD Archive

Performance of a flange joint is characterized mainly by its 'strength' and 'sealing capability'. A number of analytical and experimental studies have been conducted to study these characteristics under internal pressure loading. However, with the advent of new technological trends for high temperature and pressure applications, an increased demand for analysis is recognized. The effect of steady-state thermal loading makes the problem more complex as it leads to combined application of internal pressure and temperature. Structural and thermal analysis of a gasketed flange was computationally simulated by a finite element method and probabilistically evaluated in view of the several uncertainties …


A Left Ventricular Motion Phantom For Cardiac Magnetic Resonance Imaging, Mehmet Ersoy Jan 2011

A Left Ventricular Motion Phantom For Cardiac Magnetic Resonance Imaging, Mehmet Ersoy

ETD Archive

The mammalian left ventricle (LV) has two distinct motion patterns: wall thickening and rotation. The purpose of this study was to design and build a low-cost, non-ferromagnetic LV motion phantom, for use with cardiac magnetic resonance imaging (MRI), that is able to produce physiologically realistic LV wall thickening and rotation. Cardiac MRI is continuously expanding its range of techniques with new pulse sequences, including new tissue tagging techniques which allow intra-myocardial deformation to be visualized. An essential step in the development of new cardiac MRI techniques is validating their performance in the presence of motion. MRI-compatible dynamic motion phantoms are …


Greenometer-7: A Tool To Assess The Sustainability Of A Building's Life Cylce At The Conceptual Design Phase, Muhammad Musa Mer'eb Jan 2008

Greenometer-7: A Tool To Assess The Sustainability Of A Building's Life Cylce At The Conceptual Design Phase, Muhammad Musa Mer'eb

ETD Archive

This study presents a tool that has been developed to measure and subsequently improve the sustainability performance of a building over its entire life-cycle while still at the conceptual design stage. This forecasting tool is called GREENOMETER-7. GREENOMETER-7 is a LCA tool and it evaluates the projected building at two levels: micro- and macro-assessment. The micro-assessment level provides in-depth analysis of the building products, components, and operations however, the macro-assessment level measures the sustainability performance of the building as a whole and covers areas that are not applicable at the product or component level. Both levels consist of categories and …