Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Entire DC Network

On The Role Of The Pore Water Chemistry Of Deficient Post-Tension Grout To Promote Steel Corrosion, Samanbar Permeh Mar 2016

On The Role Of The Pore Water Chemistry Of Deficient Post-Tension Grout To Promote Steel Corrosion, Samanbar Permeh

FIU Electronic Theses and Dissertations

Corrosion failure of post-tension tendons with pre-packaged thixotropic grout was documented in Florida Bridges in less than 10 years of service. Analysis of deficient grout in Florida post-tensioned (PT) bridges where severe corrosion developed indicated enhanced sulfate ion concentration, high pore water pH, enhanced moisture and low chloride content. The corrosion wasn’t consistent with the conventional causes of steel corrosion such as bleed water accumulation in grout void spaces, chloride contamination and pore water carbonation. Corrosion development was associated with deficient grout with enhanced sulfate levels. However, limited information is available on the corrosion behavior of PT strand in grout …


Electrochemical-Mechanistic Model For Concrete Cover Cracking Due To Corrosion Initiated By Chloride Diffusion, Goli Nossoni, Ronald S. Harichandran Jun 2014

Electrochemical-Mechanistic Model For Concrete Cover Cracking Due To Corrosion Initiated By Chloride Diffusion, Goli Nossoni, Ronald S. Harichandran

Civil Engineering Faculty Publications

A holistic electrochemical-mechanistic model of the corrosion of steel reinforcing bars inside concrete that accounts for the diffusion of oxygen and moisture into the concrete and rust layers, the densification of rust due to confinement, the flow of rust into the concrete pores, the development of internal pressure due to rust buildup, and cracking of the concrete cover is presented. The relationship between the corrosion current and the pressure buildup due to the corrosion products for different concrete cover thicknesses and concrete quality was calibrated through experiments using an accelerated corrosion test with an applied current. Results from finite-element analysis …