Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Entire DC Network

Capillary Electrophoresis Of Proteins With Selective On-Line Affinity Monoliths, Jenny Marcela Armenta Blanco Nov 2006

Capillary Electrophoresis Of Proteins With Selective On-Line Affinity Monoliths, Jenny Marcela Armenta Blanco

Theses and Dissertations

The analysis of proteins in biological fluids by capillary electrophoresis (CE) is of interest in clinical chemistry. However, due to low analyte concentrations and poor concentration limits of detection (CLOD), protein analysis by this technique is frequently challenging. Coupling preconcentration techniques with CE greatly improves the CLOD. An on-line preconcentration-CE method that can selectively preconcentrate any protein for which an antibody is available would be very useful for the analysis of low abundance proteins and would establish CE as a major tool in biomarker discovery. To accomplish this, an on-line protein G monolithic preconcentrator CE system for enrichment and separation …


Membrane-Based Protein Preconcentration Microfluidic Devices, Yi Li Mar 2006

Membrane-Based Protein Preconcentration Microfluidic Devices, Yi Li

Theses and Dissertations

Interest in microchip capillary electrophoresis (CE) is growing due to the rapid analysis times provided and small sample input requirements. However, higher-concentration samples are typically needed because of the small (~pL) detection volumes in these devices. I have made membrane-based protein preconcentration systems in capillary and microchip designs to increase the detectability of low-concentration biological samples. A photopolymerized ion-permeable membrane interfaced with a microchannel in poly(methyl methacrylate) (PMMA) formed the preconcentrator. When a voltage was applied between the sample reservoir and the ionically conductive membrane in a capillary-based system, R-phycoerythrin was concentrated more than 1,000 fold, as determined by laser-induced …


The Determination Of Probes For The Indirect Detection Of Anions In Capillary Zone Electrophoresis Using Light Emitting Diode Detection, Peter Ashley Balding Jan 2006

The Determination Of Probes For The Indirect Detection Of Anions In Capillary Zone Electrophoresis Using Light Emitting Diode Detection, Peter Ashley Balding

Theses : Honours

This study investigated the potential of a number of compounds to act as probes for the indirect detection of inorganic and organic anions separated by capillary zone electrophoresis and using light emitting diodes (LED) as the light source. Desirable characteristics of the probe anion included: high molar absorptivity, moderate to high electrophoretic mobility, and having a wavelength of maximum absorbance near the maximum emission wavelength of a LED. A preliminary study led to the evaluation of eleven possible compounds. Two of these, p-nitrophenol and 4-hydroxy-3,5-dinitrobenzoic acid were selected for further study as they fulfilled the criteria previously mentioned. The optimised …


Development Of Analytical Techniques For The Analysis Of Submicron Particles And Protein Aggregates, Yohannes H. Rezenom Jan 2006

Development Of Analytical Techniques For The Analysis Of Submicron Particles And Protein Aggregates, Yohannes H. Rezenom

LSU Doctoral Dissertations

The goal of the research presented in this dissertation is to develop analytical techniques for the analysis of heterogeneous mixtures of submicron particles and protein aggregates. In Chapter 2, a simple and reproducible technique for constructing perfectly aligned gaps in fused-silica capillaries has been developed for postcolumn reagent addition with capillary electrophoresis (CE) to take advantage of laser-induced fluorescence (LIF) detection. This technique uses laser ablation with a Nd:YAG laser to create gaps of 14.0 ¡Ó 2.2 ƒÝm. These structures have been used for reagent addition for postcolumn derivatization with LIF detection and have been tested for the separation of …